{"id":29062,"date":"2026-05-22T16:47:04","date_gmt":"2026-05-22T08:47:04","guid":{"rendered":"https:\/\/www.cnspd.com\/?page_id=29062"},"modified":"2026-07-08T11:17:26","modified_gmt":"2026-07-08T03:17:26","slug":"solar-pv-surge-protection","status":"publish","type":"page","link":"https:\/\/www.cnspd.com\/es\/proteccion-contra-sobretensiones-de-energia-solar-fotovoltaica\/","title":{"rendered":"Protecci\u00f3n contra sobretensiones de energ\u00eda solar fotovoltaica"},"content":{"rendered":"<section class=\"l-section wpb_row height_large\"><div class=\"l-section-h i-cf\"><div class=\"g-cols vc_row via_grid cols_1 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\"><div class=\"wpb_column vc_column_container stretched\"><div class=\"vc_column-inner\"><div class=\"w-html\"><div class=\"cnspd-solar-page\">\n\n<style>\n.cnspd-solar-page{\n  width:100% !important;\n  max-width:none !important;\n  margin:0 !important;\n  padding:0 !important;\n  font-family:Arial,Helvetica,sans-serif;\n  color:#102033;\n  background:#ffffff;\n  line-height:1.6;\n}\n.cnspd-solar-page *{box-sizing:border-box;}\n.cnspd-container{\n  max-width:1180px;\n  margin:0 auto;\n  padding:0 22px;\n}\n.cnspd-section{\n  padding:78px 0;\n}\n.cnspd-section-tight{\n  padding:58px 0;\n}\n.cnspd-blue-bg{\n  background:#f7fbff;\n}\n.cnspd-white-bg{\n  background:#ffffff;\n}\n.cnspd-dark{\n  background:linear-gradient(180deg,#f3f8ff 0%,#ffffff 100%);\n  color:#102033;\n}\n.cnspd-dark .cnspd-title h2{\n  color:#071b33 !important;\n}\n.cnspd-dark .cnspd-title .eyebrow{\n  color:#0c63b8 !important;\n}\n.cnspd-dark .cnspd-title p{\n  color:#5d6b7c !important;\n}\n\n\/* Typography *\/\n.cnspd-title{\n  max-width:820px;\n  margin-bottom:38px;\n}\n.cnspd-title.center{\n  text-align:center;\n  margin-left:auto;\n  margin-right:auto;\n}\n.cnspd-title .eyebrow{\n  color:#0c63b8;\n  font-weight:800;\n  text-transform:uppercase;\n  font-size:13px;\n  letter-spacing:1.2px;\n  margin-bottom:10px;\n}\n.cnspd-title h2{\n  font-size:38px;\n  line-height:1.16;\n  margin:0 0 16px;\n  color:#071b33;\n  letter-spacing:-.6px;\n}\n.cnspd-title p{\n  font-size:17px;\n  color:#5d6b7c;\n  margin:0;\n}\n.cnspd-lead{\n  font-size:18px;\n  color:#4f6072;\n  margin:0 0 22px;\n}\n.cnspd-small{\n  font-size:14px;\n  color:#69788a;\n  margin:0;\n}\n\n\/* Buttons - strong Impreza\/WPBakery override *\/\n.cnspd-btns{\n  display:flex;\n  gap:14px;\n  flex-wrap:wrap;\n  align-items:center;\n}\n.cnspd-btn,\n.cnspd-btn:visited,\n.cnspd-btn:hover,\n.cnspd-btn:focus,\n.cnspd-btn:active{\n  display:inline-flex !important;\n  align-items:center !important;\n  justify-content:center !important;\n  min-width:180px;\n  min-height:48px;\n  padding:14px 22px !important;\n  border-radius:8px !important;\n  text-decoration:none !important;\n  font-weight:800 !important;\n  font-size:15px !important;\n  line-height:1.2 !important;\n  transition:.25s;\n  opacity:1 !important;\n  visibility:visible !important;\n  white-space:normal !important;\n  outline:none !important;\n}\n.cnspd-btn span,\n.cnspd-btn:visited span,\n.cnspd-btn:hover span,\n.cnspd-btn:focus span,\n.cnspd-btn:active span{\n  display:inline-block !important;\n  visibility:visible !important;\n  opacity:1 !important;\n  line-height:1.2 !important;\n  color:inherit !important;\n  text-decoration:none !important;\n  white-space:normal !important;\n}\n.cnspd-btn-primary,\n.cnspd-btn-primary:visited,\n.cnspd-btn-primary:hover,\n.cnspd-btn-primary:focus,\n.cnspd-btn-primary:active{\n  background:#ffffff !important;\n  color:#0b2f5c !important;\n  border:1px solid #ffffff !important;\n}\n.cnspd-btn-primary span,\n.cnspd-btn-primary:visited span,\n.cnspd-btn-primary:hover span,\n.cnspd-btn-primary:focus span,\n.cnspd-btn-primary:active span{\n  color:#0b2f5c !important;\n}\n.cnspd-btn-primary:hover{\n  background:#eaf3ff !important;\n  border-color:#eaf3ff !important;\n}\n.cnspd-btn-blue,\n.cnspd-btn-blue:visited,\n.cnspd-btn-blue:hover,\n.cnspd-btn-blue:focus,\n.cnspd-btn-blue:active{\n  background:#004898 !important;\n  color:#ffffff !important;\n  border:1px solid #004898 !important;\n}\n.cnspd-btn-blue span,\n.cnspd-btn-blue:visited span,\n.cnspd-btn-blue:hover span,\n.cnspd-btn-blue:focus span,\n.cnspd-btn-blue:active span{\n  color:#ffffff !important;\n}\n.cnspd-btn-blue:hover{\n  background:#073b78 !important;\n  border-color:#073b78 !important;\n}\n.cnspd-btn-outline,\n.cnspd-btn-outline:visited,\n.cnspd-btn-outline:hover,\n.cnspd-btn-outline:focus,\n.cnspd-btn-outline:active{\n  background:transparent !important;\n  color:#ffffff !important;\n  border:1px solid rgba(255,255,255,.5) !important;\n}\n.cnspd-btn-outline span,\n.cnspd-btn-outline:visited span,\n.cnspd-btn-outline:hover span,\n.cnspd-btn-outline:focus span,\n.cnspd-btn-outline:active span{\n  color:#ffffff !important;\n}\n.cnspd-btn-outline:hover{\n  background:rgba(255,255,255,.12) !important;\n}\n.cnspd-btn-light-outline,\n.cnspd-btn-light-outline:visited,\n.cnspd-btn-light-outline:hover,\n.cnspd-btn-light-outline:focus,\n.cnspd-btn-light-outline:active{\n  background:#ffffff !important;\n  color:#004898 !important;\n  border:1px solid #cfe0f2 !important;\n}\n.cnspd-btn-light-outline span,\n.cnspd-btn-light-outline:visited span,\n.cnspd-btn-light-outline:hover span,\n.cnspd-btn-light-outline:focus span,\n.cnspd-btn-light-outline:active span{\n  color:#004898 !important;\n}\n.cnspd-btn-light-outline:hover{\n  background:#f4f9ff !important;\n  border-color:#004898 !important;\n}\n\n\/* Hero *\/\n.cnspd-hero{\n  position:relative;\n  background-image:url('https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/07\/Solar-farm-at-sunrise-with-protective-modules-scaled.webp');\n  background-size:cover;\n  background-position:center center;\n  background-repeat:no-repeat;\n  color:#102033;\n  padding:132px 0 56px;\n  min-height:660px;\n  overflow:hidden;\n  display:flex;\n  align-items:center;\n}\n.cnspd-hero:before{\n  content:none !important;\n  display:none !important;\n}\n.cnspd-hero .cnspd-container{\n  position:relative;\n  z-index:2;\n  max-width:1480px;\n}\n.cnspd-hero-grid{\n  display:block;\n  max-width:525px;\n}\n.cnspd-hero-content{\n  background:rgba(255,255,255,.74);\n  border:1px solid rgba(255,255,255,.72);\n  border-radius:22px;\n  padding:26px 28px 28px;\n  box-shadow:0 16px 42px rgba(10,38,71,.10);\n  backdrop-filter:blur(7px);\n  -webkit-backdrop-filter:blur(7px);\n}\n.cnspd-badge{\n  display:inline-flex;\n  align-items:center;\n  padding:7px 13px;\n  border:1px solid #cfe0f2;\n  border-radius:999px;\n  font-size:13px;\n  color:#004898;\n  background:rgba(255,255,255,.86);\n  margin-bottom:18px;\n  font-weight:800;\n}\n.cnspd-hero h1{\n  font-size:43px;\n  line-height:1.1;\n  margin:0 0 18px;\n  letter-spacing:-1.2px;\n  color:#071b33 !important;\n}\n.cnspd-hero p{\n  font-size:17px;\n  line-height:1.62;\n  color:#34485f;\n  max-width:500px;\n  margin:0 0 24px;\n}\n.cnspd-trust-row{\n  display:grid;\n  grid-template-columns:repeat(4,1fr);\n  gap:14px;\n  margin-top:34px;\n  max-width:1060px;\n}\n.cnspd-trust-item{\n  background:rgba(255,255,255,.82);\n  border:1px solid rgba(255,255,255,.76);\n  border-radius:14px;\n  padding:15px 16px;\n  box-shadow:0 8px 22px rgba(10,38,71,.07);\n  backdrop-filter:blur(5px);\n  -webkit-backdrop-filter:blur(5px);\n}\n.cnspd-trust-item strong{\n  display:block;\n  font-size:19px;\n  margin-bottom:3px;\n  color:#071b33 !important;\n}\n.cnspd-trust-item span{\n  color:#5d6b7c;\n  font-size:13px;\n}\n\n\/* Quick Answer *\/\n.cnspd-answer-box{\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:20px;\n  padding:30px;\n  box-shadow:0 12px 32px rgba(10,38,71,.06);\n}\n.cnspd-answer-grid{\n  display:grid;\n  grid-template-columns:repeat(4,1fr);\n  gap:16px;\n}\n.cnspd-answer-card{\n  background:#f7faff;\n  border:1px solid #dce8f5;\n  border-radius:16px;\n  padding:20px;\n}\n.cnspd-answer-card strong{\n  display:block;\n  color:#071b33;\n  font-size:17px;\n  margin-bottom:8px;\n}\n.cnspd-answer-card span{\n  display:block;\n  color:#5d6b7c;\n  font-size:14px;\n}\n\n\/* Tables *\/\n.cnspd-table-wrap{\n  overflow-x:auto;\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:18px;\n  box-shadow:0 10px 28px rgba(10,38,71,.05);\n}\n.cnspd-data-table{\n  width:100%;\n  border-collapse:collapse;\n  min-width:920px;\n}\n.cnspd-model-table{\n  min-width:1180px;\n}\n.cnspd-data-table .cnspd-nowrap{\n  white-space:nowrap;\n}\n.cnspd-data-table th{\n  background:#004898;\n  color:#ffffff;\n  text-align:left;\n  padding:16px;\n  border:1px solid #1a62a9;\n  font-size:14px;\n  vertical-align:top;\n}\n.cnspd-data-table td{\n  padding:16px;\n  border:1px solid #dce8f5;\n  vertical-align:top;\n  color:#4f6072;\n  font-size:14px;\n}\n.cnspd-data-table tr:nth-child(even) td{\n  background:#f7faff;\n}\n.cnspd-data-table td:first-child{\n  font-weight:800;\n  color:#071b33;\n}\n.cnspd-data-table a{\n  color:#0c63b8;\n  font-weight:800;\n  text-decoration:none !important;\n}\n.cnspd-data-table a:hover{\n  text-decoration:underline !important;\n}\n.cnspd-note{\n  margin-top:18px;\n  padding:18px 20px;\n  border-left:5px solid #0c63b8;\n  background:#f7faff;\n  border-radius:12px;\n  color:#4f6072;\n}\n.cnspd-note a{\n  color:#0c63b8;\n  font-weight:800;\n  text-decoration:none !important;\n}\n\n\/* Cards *\/\n.cnspd-card-grid{\n  display:grid;\n  grid-template-columns:repeat(3,1fr);\n  gap:22px;\n}\n.cnspd-card{\n  background:#ffffff;\n  border:1px solid #e5edf5;\n  border-radius:18px;\n  padding:28px;\n  box-shadow:0 10px 30px rgba(10,38,71,.06);\n}\n.cnspd-card h3{\n  font-size:21px;\n  margin:0 0 12px;\n  color:#071b33;\n}\n.cnspd-card p{\n  color:#5d6b7c;\n  margin:0;\n}\n.cnspd-dark .cnspd-card{\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  box-shadow:0 10px 30px rgba(10,38,71,.05);\n}\n.cnspd-dark .cnspd-card h3{\n  color:#071b33 !important;\n}\n.cnspd-dark .cnspd-card p{\n  color:#5d6b7c !important;\n}\n\n\/* Product range *\/\n.cnspd-product-grid{\n  display:grid;\n  grid-template-columns:repeat(4,1fr);\n  gap:18px;\n}\n.cnspd-product-card{\n  display:flex;\n  flex-direction:column;\n  justify-content:space-between;\n  min-height:100%;\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:18px;\n  padding:22px;\n  box-shadow:0 10px 26px rgba(10,38,71,.05);\n  transition:.25s;\n}\n.cnspd-product-card:hover{\n  transform:translateY(-3px);\n  border-color:#0c63b8;\n  box-shadow:0 14px 34px rgba(10,38,71,.1);\n}\n.cnspd-product-tag{\n  display:inline-flex;\n  align-items:center;\n  width:max-content;\n  max-width:100%;\n  padding:6px 10px;\n  border-radius:999px;\n  background:#eef6ff;\n  color:#004898;\n  font-size:12px;\n  font-weight:800;\n  margin-bottom:14px;\n}\n.cnspd-product-image-wrap{\n  width:100%;\n  height:188px;\n  display:flex;\n  align-items:center;\n  justify-content:center;\n  background:linear-gradient(180deg,#f8fbff 0%,#ffffff 100%);\n  border:1px solid #e0ebf7;\n  border-radius:16px;\n  padding:14px;\n  margin:0 0 18px;\n  overflow:hidden;\n}\n.cnspd-product-image-wrap img{\n  width:100%;\n  height:100%;\n  object-fit:contain;\n  display:block;\n  transition:.25s;\n}\n.cnspd-product-card:hover .cnspd-product-image-wrap img{\n  transform:scale(1.04);\n}\n.cnspd-product-card h3{\n  font-size:19px;\n  line-height:1.25;\n  margin:0 0 10px;\n  color:#071b33;\n}\n.cnspd-product-card p{\n  color:#5d6b7c;\n  font-size:14px;\n  margin:0 0 14px;\n}\n.cnspd-product-meta{\n  display:grid;\n  grid-template-columns:1fr;\n  gap:8px;\n  margin:0 0 18px;\n}\n.cnspd-product-meta div{\n  background:#f7faff;\n  border:1px solid #e0ebf7;\n  border-radius:10px;\n  padding:9px 10px;\n  font-size:13px;\n  color:#4f6072;\n}\n.cnspd-product-meta strong{\n  color:#071b33;\n}\n.cnspd-product-card a.cnspd-product-link,\n.cnspd-product-card a.cnspd-product-link:visited,\n.cnspd-product-card a.cnspd-product-link:hover,\n.cnspd-product-card a.cnspd-product-link:focus,\n.cnspd-product-card a.cnspd-product-link:active{\n  display:inline-flex !important;\n  justify-content:center !important;\n  align-items:center !important;\n  padding:12px 14px !important;\n  background:#004898 !important;\n  color:#ffffff !important;\n  border-radius:8px !important;\n  font-weight:800 !important;\n  text-decoration:none !important;\n  line-height:1.2 !important;\n}\n.cnspd-product-card a.cnspd-product-link span,\n.cnspd-product-card a.cnspd-product-link:visited span,\n.cnspd-product-card a.cnspd-product-link:hover span,\n.cnspd-product-card a.cnspd-product-link:focus span,\n.cnspd-product-card a.cnspd-product-link:active span{\n  display:inline-block !important;\n  color:#ffffff !important;\n  visibility:visible !important;\n  opacity:1 !important;\n  line-height:1.2 !important;\n}\n\n\/* Architecture *\/\n.cnspd-flow{\n  display:grid;\n  grid-template-columns:repeat(6,1fr);\n  gap:14px;\n  margin-top:36px;\n}\n.cnspd-node{\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:16px;\n  padding:20px;\n  text-align:center;\n  box-shadow:0 8px 24px rgba(10,38,71,.05);\n}\n.cnspd-node span{\n  display:block;\n  color:#0c63b8;\n  font-weight:800;\n  margin-bottom:8px;\n}\n.cnspd-node strong{\n  display:block;\n  font-size:16px;\n  color:#071b33;\n}\n.cnspd-subflow{\n  margin-top:18px;\n  padding:22px;\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:16px;\n}\n.cnspd-subflow strong{\n  display:block;\n  color:#071b33;\n  margin-bottom:8px;\n}\n.cnspd-subflow p{\n  margin:0;\n  color:#5d6b7c;\n}\n\n\/* Two Column *\/\n.cnspd-two-col{\n  display:grid;\n  grid-template-columns:1fr 1fr;\n  gap:44px;\n  align-items:center;\n}\n.cnspd-img-card{\n  border-radius:22px;\n  overflow:hidden;\n  box-shadow:0 18px 45px rgba(10,38,71,.12);\n}\n.cnspd-img-card img{\n  width:100%;\n  height:420px;\n  object-fit:cover;\n  display:block;\n}\n.cnspd-list{\n  margin:0;\n  padding:0;\n  list-style:none;\n}\n.cnspd-list li{\n  padding:14px 0 14px 34px;\n  border-bottom:1px solid #e6eef7;\n  position:relative;\n  color:#4f6072;\n}\n.cnspd-list li:before{\n  content:\"\u2713\";\n  position:absolute;\n  left:0;\n  top:14px;\n  color:#0c63b8;\n  font-weight:900;\n}\n\n\/* Installation grid *\/\n.cnspd-install-grid{\n  display:grid;\n  grid-template-columns:repeat(3,1fr);\n  gap:20px;\n}\n.cnspd-install-card{\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:18px;\n  padding:26px;\n  box-shadow:0 10px 26px rgba(10,38,71,.05);\n}\n.cnspd-install-card h3{\n  color:#071b33;\n  font-size:21px;\n  margin:0 0 12px;\n}\n.cnspd-install-card ul{\n  margin:0;\n  padding-left:19px;\n  color:#4f6072;\n}\n.cnspd-install-card li{\n  margin:8px 0;\n}\n\n\/* Application tags *\/\n.cnspd-app-tags{\n  display:flex;\n  flex-wrap:wrap;\n  gap:14px;\n  justify-content:center;\n  max-width:980px;\n  margin:0 auto;\n}\n.cnspd-app-tags span{\n  display:inline-flex;\n  align-items:center;\n  padding:12px 18px;\n  border:1px solid #dce8f5;\n  border-radius:999px;\n  background:#f7faff;\n  color:#17324d;\n  font-weight:700;\n  font-size:15px;\n}\n\n\/* Topic details *\/\n.cnspd-topic-grid{\n  display:grid;\n  grid-template-columns:repeat(3,1fr);\n  gap:22px;\n}\n.cnspd-topic-card{\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:18px;\n  padding:28px;\n  text-decoration:none !important;\n  color:#102033;\n  transition:.25s;\n  min-height:190px;\n  display:flex;\n  flex-direction:column;\n  justify-content:space-between;\n}\n.cnspd-topic-card:hover{\n  transform:translateY(-4px);\n  box-shadow:0 14px 34px rgba(10,38,71,.1);\n  border-color:#0c63b8;\n}\n.cnspd-topic-card h3{\n  font-size:20px;\n  margin:0 0 12px;\n  color:#071b33;\n}\n.cnspd-topic-card p{\n  color:#5d6b7c;\n  margin:0 0 18px;\n}\n.cnspd-topic-card span{\n  color:#0c63b8;\n  font-weight:800;\n}\n.cnspd-topic-detail{\n  scroll-margin-top:90px;\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:20px;\n  padding:30px;\n  margin-bottom:20px;\n  box-shadow:0 10px 28px rgba(10,38,71,.04);\n}\n.cnspd-topic-detail h3{\n  font-size:24px;\n  margin:0 0 12px;\n  color:#071b33;\n}\n.cnspd-topic-detail p{\n  color:#5d6b7c;\n  margin:0 0 18px;\n}\n.cnspd-topic-points{\n  display:grid;\n  grid-template-columns:repeat(3,1fr);\n  gap:14px;\n}\n.cnspd-topic-points div{\n  background:#f7faff;\n  border:1px solid #e0ebf7;\n  border-radius:14px;\n  padding:16px;\n}\n.cnspd-topic-points strong{\n  display:block;\n  color:#071b33;\n  margin-bottom:6px;\n}\n.cnspd-topic-points span{\n  color:#5d6b7c;\n  font-size:14px;\n}\n\n\/* Factory proof *\/\n.cnspd-proof-grid{\n  display:grid;\n  grid-template-columns:repeat(4,1fr);\n  gap:18px;\n}\n.cnspd-proof{\n  border-radius:16px;\n  overflow:hidden;\n  background:#ffffff;\n  border:1px solid #e5edf5;\n}\n.cnspd-proof img{\n  width:100%;\n  height:170px;\n  object-fit:cover;\n  display:block;\n}\n.cnspd-proof div{\n  padding:18px;\n}\n.cnspd-proof strong{\n  display:block;\n  margin-bottom:6px;\n  color:#071b33;\n}\n.cnspd-proof p{\n  margin:0;\n  color:#5d6b7c;\n  font-size:14px;\n}\n\n\/* Resource cards *\/\n.cnspd-resource-grid{\n  display:grid;\n  grid-template-columns:repeat(4,1fr);\n  gap:20px;\n}\n.cnspd-resource{\n  background:#ffffff;\n  border:1px solid #dce8f5;\n  border-radius:18px;\n  padding:26px;\n}\n.cnspd-resource strong{\n  display:block;\n  font-size:18px;\n  margin-bottom:10px;\n  color:#071b33;\n}\n.cnspd-resource p{\n  color:#5d6b7c;\n  margin:0;\n  font-size:14px;\n}\n.cnspd-resource a,\n.cnspd-resource a:visited,\n.cnspd-resource a:hover,\n.cnspd-resource a:focus,\n.cnspd-resource a:active{\n  display:inline-block;\n  margin-top:16px;\n  color:#0c63b8 !important;\n  font-weight:800;\n  text-decoration:none !important;\n}\n\n\/* FAQ *\/\n.cnspd-faq{\n  max-width:900px;\n  margin:0 auto;\n}\n.cnspd-faq details{\n  border-bottom:1px solid #dce8f5;\n  padding:20px 0;\n}\n.cnspd-faq summary{\n  cursor:pointer;\n  font-weight:800;\n  font-size:18px;\n  color:#071b33;\n}\n.cnspd-faq p{\n  color:#5d6b7c;\n  margin:14px 0 0;\n}\n\n\/* Final CTA *\/\n.cnspd-final{\n  background:linear-gradient(120deg,#004898,#0b5faf) !important;\n  color:#ffffff;\n  text-align:center;\n  padding:85px 20px !important;\n  margin-bottom:0 !important;\n}\n.cnspd-final h2{\n  font-size:42px;\n  line-height:1.18;\n  margin:0 0 16px;\n  color:#ffffff !important;\n}\n.cnspd-final p{\n  color:#dbeaff !important;\n  max-width:760px;\n  margin:0 auto 26px;\n  font-size:18px;\n}\n.cnspd-final-note{\n  max-width:780px;\n  margin:0 auto 34px;\n  color:#c9dcf5 !important;\n  font-size:16px;\n}\n\n\/* Strong fix: remove WPBakery \/ Impreza extra bottom gap before footer *\/\n.l-main,\n.l-main .l-section,\n.l-main .l-section-h,\n.l-main .vc_row,\n.l-main .vc_column_container,\n.l-main .vc_column-inner,\n.l-main .wpb_wrapper,\n.l-main .wpb_content_element,\n.l-main .wpb_raw_html,\n.l-content{\n  margin-bottom:0 !important;\n  padding-bottom:0 !important;\n}\n.l-main .l-section:last-child,\n.l-main .l-section:last-child .l-section-h{\n  margin-bottom:0 !important;\n  padding-bottom:0 !important;\n}\n.l-footer{\n  margin-top:0 !important;\n  border-top:1px solid #dce8f5 !important;\n}\n\n\/* Responsive *\/\n@media(max-width:1100px){\n  .cnspd-product-grid,\n  .cnspd-resource-grid{\n    grid-template-columns:repeat(2,1fr);\n  }\n  .cnspd-answer-grid{\n    grid-template-columns:repeat(2,1fr);\n  }\n}\n@media(max-width:1000px){\n  .cnspd-topic-grid{\n    grid-template-columns:repeat(2,1fr);\n  }\n  .cnspd-topic-points{\n    grid-template-columns:1fr;\n  }\n}\n@media(max-width:900px){\n  .cnspd-hero{\n    padding-top:112px !important;\n    padding-bottom:46px !important;\n    min-height:620px !important;\n    background-image:url('https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/07\/Solar-farm-at-sunrise-with-protective-modules-scaled.webp') !important;\n    background-position:62% center !important;\n  }\n  .cnspd-hero-grid{\n    max-width:100% !important;\n  }\n  .cnspd-hero-content{\n    background:rgba(255,255,255,.88) !important;\n    border-radius:18px !important;\n    padding:22px 20px !important;\n    box-shadow:0 14px 34px rgba(10,38,71,.12) !important;\n    backdrop-filter:blur(7px) !important;\n    -webkit-backdrop-filter:blur(7px) !important;\n  }\n  .cnspd-container{\n    padding-left:18px !important;\n    padding-right:18px !important;\n  }\n  .cnspd-hero-grid,\n  .cnspd-two-col{\n    grid-template-columns:1fr !important;\n    gap:28px !important;\n  }\n  .cnspd-hero h1{\n    font-size:34px !important;\n    line-height:1.12 !important;\n    letter-spacing:-.8px !important;\n  }\n  .cnspd-hero p{\n    font-size:16px !important;\n    line-height:1.62 !important;\n  }\n  .cnspd-trust-row{\n    grid-template-columns:1fr 1fr !important;\n    gap:12px !important;\n    margin-top:22px !important;\n  }\n  .cnspd-trust-item{\n    padding:13px !important;\n  }\n  .cnspd-trust-item strong{\n    font-size:17px !important;\n  }\n  .cnspd-section{\n    padding:54px 0 !important;\n  }\n  .cnspd-title{\n    margin-bottom:28px !important;\n  }\n  .cnspd-title h2{\n    font-size:28px !important;\n    line-height:1.22 !important;\n  }\n  .cnspd-title p,\n  .cnspd-lead{\n    font-size:15px !important;\n    line-height:1.65 !important;\n  }\n  .cnspd-card-grid,\n  .cnspd-install-grid,\n  .cnspd-proof-grid{\n    grid-template-columns:1fr 1fr !important;\n    gap:14px !important;\n  }\n  .cnspd-card,\n  .cnspd-answer-box,\n  .cnspd-answer-card,\n  .cnspd-product-card,\n  .cnspd-install-card,\n  .cnspd-topic-card,\n  .cnspd-topic-detail,\n  .cnspd-resource{\n    padding:22px !important;\n    border-radius:16px !important;\n  }\n  .cnspd-product-image-wrap{\n    height:190px !important;\n  }\n  .cnspd-flow{\n    grid-template-columns:1fr 1fr !important;\n    gap:12px !important;\n  }\n  .cnspd-node{\n    padding:16px 12px !important;\n  }\n  .cnspd-img-card img{\n    height:240px !important;\n  }\n  .cnspd-app-tags{\n    display:grid !important;\n    grid-template-columns:1fr 1fr !important;\n    gap:10px !important;\n    justify-content:unset !important;\n    max-width:100% !important;\n  }\n  .cnspd-app-tags span{\n    width:100% !important;\n    justify-content:center !important;\n    text-align:center !important;\n    font-size:13px !important;\n    line-height:1.3 !important;\n    padding:12px 10px !important;\n    border-radius:14px !important;\n    font-weight:700 !important;\n  }\n  .cnspd-final{\n    padding-top:58px !important;\n    padding-bottom:66px !important;\n  }\n  .cnspd-final h2{\n    font-size:28px !important;\n    line-height:1.24 !important;\n  }\n  .cnspd-final p,\n  .cnspd-final-note{\n    font-size:15px !important;\n    line-height:1.65 !important;\n  }\n}\n@media(max-width:640px){\n  .cnspd-btns{\n    flex-direction:column !important;\n    gap:12px !important;\n    align-items:stretch !important;\n  }\n  .cnspd-btn{\n    width:100% !important;\n    min-width:100% !important;\n  }\n  .cnspd-card-grid,\n  .cnspd-install-grid,\n  .cnspd-product-grid,\n  .cnspd-resource-grid,\n  .cnspd-topic-grid,\n  .cnspd-proof-grid,\n  .cnspd-answer-grid{\n    grid-template-columns:1fr !important;\n  }\n  .cnspd-product-image-wrap{\n    height:215px !important;\n  }\n}\n@media(max-width:420px){\n  .cnspd-hero{\n    padding-top:108px !important;\n    min-height:600px !important;\n    background-position:center center !important;\n  }\n  .cnspd-hero h1{\n    font-size:30px !important;\n  }\n  .cnspd-trust-row,\n  .cnspd-flow{\n    grid-template-columns:1fr !important;\n  }\n  .cnspd-app-tags{\n    grid-template-columns:1fr 1fr !important;\n  }\n  .cnspd-app-tags span{\n    font-size:12.5px !important;\n    min-height:52px !important;\n  }\n}\n<\/style>\n\n<section class=\"cnspd-hero\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-hero-grid\">\n      <div class=\"cnspd-hero-content\">\n        <div class=\"cnspd-badge\">Solar PV DC SPD Selection & System Protection<\/div>\n        <h1>Solar PV Surge Protection Guide for DC SPD Selection<\/h1>\n        <p>\n          Select surge protection for PV strings, combiner boxes, inverter DC inputs,\n          inverter AC outputs, distribution panels, and monitoring lines. LEEYEE supplies\n          600V, 1000V, and 1500V PV DC SPDs for solar PV systems and OEM projects.\n        <\/p>\n        <div class=\"cnspd-btns\">\n          <a class=\"cnspd-btn cnspd-btn-blue leeyee-site-popup-btn\" href=\"javascript:void(0);\"><span>Request Solar SPD Selection<\/span><\/a>\n          <a class=\"cnspd-btn cnspd-btn-light-outline\" href=\"#solar-spd-selection-table\"><span>View Selection Table<\/span><\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"cnspd-trust-row\">\n      <div class=\"cnspd-trust-item\"><strong>600V \/ 1000V \/ 1500V<\/strong><span>PV DC SPD voltage options<\/span><\/div>\n      <div class=\"cnspd-trust-item\"><strong>IEC 61643-31<\/strong><span>PV SPD selection logic<\/span><\/div>\n      <div class=\"cnspd-trust-item\"><strong>T\u00dcV \/ CE \/ CB<\/strong><span>Certificate documents by model<\/span><\/div>\n      <div class=\"cnspd-trust-item\"><strong>OEM Ready<\/strong><span>Label, packaging, and batch supply<\/span><\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section-tight cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-answer-box\">\n      <div class=\"cnspd-title center\">\n        <div class=\"eyebrow\">Quick Answer<\/div>\n        <h2>How Should Surge Protection Be Designed For Solar PV Systems?<\/h2>\n        <p>\n          A solar PV system normally needs coordinated surge protection on the DC side,\n          AC side, and communication lines where wired monitoring interfaces are exposed.\n        <\/p>\n      <\/div>\n\n      <div class=\"cnspd-answer-grid\">\n        <div class=\"cnspd-answer-card\">\n          <strong>DC Side<\/strong>\n          <span>Use PV DC SPDs for strings, combiner boxes, and inverter DC inputs. Select by calculated maximum string open-circuit voltage: Ucpv \u2265 Uoc,max.<\/span>\n        <\/div>\n        <div class=\"cnspd-answer-card\">\n          <strong>AC Side<\/strong>\n          <span>Use AC SPDs at inverter output, AC distribution, and main panels according to the building protection design.<\/span>\n        <\/div>\n        <div class=\"cnspd-answer-card\">\n          <strong>Type Selection<\/strong>\n          <span>Type 2 is common for induced surges. Type 1+2 is used where partial lightning current may enter the electrical system.<\/span>\n        <\/div>\n        <div class=\"cnspd-answer-card\">\n          <strong>Wiring & Grounding<\/strong>\n          <span>Keep SPD leads short and connect to a low-impedance grounding path. Long cable routes may need protection near both ends.<\/span>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"solar-spd-selection-table\" class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">PV DC SPD Selection Table<\/div>\n      <h2>Choose Solar PV DC SPD By Ucpv, Type, And Project Voltage<\/h2>\n      <p>\n        Start with the calculated maximum PV string open-circuit voltage at the minimum design temperature:\n        <strong>Ucpv \u2265 Uoc,max<\/strong>. Then confirm Type 2 or Type 1+2, poles, In, Imax, Iimp, Up,\n        certificate scope, wiring diagram, and cabinet installation position.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-table-wrap\">\n      <table class=\"cnspd-data-table cnspd-model-table\">\n        <thead>\n          <tr>\n            <th>LEEYEE Model<\/th>\n            <th class=\"cnspd-nowrap\">Ucpv \/ Voltage<\/th>\n            <th>SPD Type<\/th>\n            <th>Poles \/ Configuration<\/th>\n            <th class=\"cnspd-nowrap\">In \/ Imax<\/th>\n            <th class=\"cnspd-nowrap\">Iimp<\/th>\n            <th class=\"cnspd-nowrap\">Up<\/th>\n            <th>Typical Position<\/th>\n            <th>Certificate Status<\/th>\n            <th>Product Page<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>LY1-C40PV3S-600V<\/td>\n            <td>600V DC<\/td>\n            <td>Class II \/ Type 2 DC SPD<\/td>\n            <td>3-Pole pluggable design<\/td>\n            <td>20kA \/ 40kA, 8\/20\u03bcs<\/td>\n            <td>\u2014<\/td>\n            <td>\u2264 2.2kV<\/td>\n            <td>PV combiner box, inverter DC input, 600V DC distribution<\/td>\n            <td>T\u00dcV \/ CE documents available<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/ly1-c40pv3s-600v-pluggable-multi-pole-spd-product\/\" target=\"_blank\" rel=\"noopener\">View 600V SPD<\/a><\/td>\n          <\/tr>\n          <tr>\n            <td>LY1-C40PV2S-1000V<\/td>\n            <td>1000V DC<\/td>\n            <td>Class I+II \/ Type 1+2 DC SPD<\/td>\n            <td>2-Pole pluggable design<\/td>\n            <td>20kA \/ 40kA, 8\/20\u03bcs<\/td>\n            <td>6.25kA, 10\/350\u03bcs<\/td>\n            <td>3.6kV<\/td>\n            <td>PV strings, combiner boxes, inverter DC input<\/td>\n            <td>T\u00dcV \/ CE \/ CB documents available<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/ly1-c40pv2s1000v-pluggable-dc-spd-product\/\" target=\"_blank\" rel=\"noopener\">View 1000V 2P SPD<\/a><\/td>\n          <\/tr>\n          <tr>\n            <td>LY1-C40PV3S-1000V D4<\/td>\n            <td>1000V DC<\/td>\n            <td>Class I+II \/ Type 1+2 DC SPD<\/td>\n            <td>3-Pole D4 configuration<\/td>\n            <td>20kA \/ 40kA, 8\/20\u03bcs<\/td>\n            <td>6.25kA, 10\/350\u03bcs<\/td>\n            <td>3.6kV<\/td>\n            <td>Combiner box and inverter cabinet designs requiring D4 wiring configuration<\/td>\n            <td>T\u00dcV \/ CE \/ CB scope should be confirmed by exact model<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/ly1-c40pv3s1000vd4-pluggable-dc-spd-product\/\" target=\"_blank\" rel=\"noopener\">View 1000V D4 SPD<\/a><\/td>\n          <\/tr>\n          <tr>\n            <td>LY1-C40PV3S-1500V D4<\/td>\n            <td>1500V DC<\/td>\n            <td>Class I+II \/ Type 1+2 DC SPD<\/td>\n            <td>3P multi-pole design<\/td>\n            <td>20kA \/ 40kA, 8\/20\u03bcs<\/td>\n            <td>6.25kA, 10\/350\u03bcs<\/td>\n            <td>5.6kV<\/td>\n            <td>Commercial and utility-scale PV systems, high-voltage DC cabinets<\/td>\n            <td>T\u00dcV \/ CE documents available<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/ly1-c40pv3s-1500vd4-pluggable-multi-pole-spd-product\/\" target=\"_blank\" rel=\"noopener\">View 1500V D4 SPD<\/a><\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"cnspd-note\">\n      This table is for buyer pre-selection. For formal project filing, tender submission, OEM marking, or regulated market approval,\n      request the latest datasheet and certificate copy, then confirm exact model, voltage rating, pole configuration, wiring diagram,\n      backup protection, and certificate scope before use.\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Recommended Product Range<\/div>\n      <h2>LEEYEE Solar PV DC SPD Product Pages<\/h2>\n      <p>\n        These product pages connect the solar PV surge protection guide to model-level specifications,\n        certificate documents, datasheets, and OEM order discussion.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-product-grid\">\n      <div class=\"cnspd-product-card\">\n        <div>\n          <span class=\"cnspd-product-tag\">600V PV DC SPD<\/span>\n          <div class=\"cnspd-product-image-wrap\">\n            <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2024\/06\/%E5%9B%BE%E5%B1%8291.jpg\" alt=\"LY1-C40PV3S-600V 600V PV DC surge protective device product image\" loading=\"lazy\">\n          <\/div>\n          <h3>LY1-C40PV3S-600V<\/h3>\n          <p>For 600V class PV strings, combiner boxes, and inverter DC protection.<\/p>\n          <div class=\"cnspd-product-meta\">\n            <div><strong>Type:<\/strong> Class II \/ Type 2<\/div>\n            <div><strong>Ucpv:<\/strong> 600V DC<\/div>\n            <div><strong>In \/ Imax:<\/strong> 20kA \/ 40kA<\/div>\n            <div><strong>Certificate:<\/strong> T\u00dcV \/ CE<\/div>\n            <div><strong>Buyer:<\/strong> OEM, importer, panel builder<\/div>\n          <\/div>\n        <\/div>\n        <a class=\"cnspd-product-link\" href=\"https:\/\/www.cnspd.com\/ly1-c40pv3s-600v-pluggable-multi-pole-spd-product\/\" target=\"_blank\" rel=\"noopener\"><span>View Product<\/span><\/a>\n      <\/div>\n\n      <div class=\"cnspd-product-card\">\n        <div>\n          <span class=\"cnspd-product-tag\">1000V PV DC SPD<\/span>\n          <div class=\"cnspd-product-image-wrap\">\n            <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2024\/06\/%E5%9B%BE%E5%B1%8286.jpg\" alt=\"LY1-C40PV2S-1000V 1000V PV DC surge protective device product image\" loading=\"lazy\">\n          <\/div>\n          <h3>LY1-C40PV2S-1000V<\/h3>\n          <p>For common 1000V PV DC systems, inverter input protection, and combiner box use. Class I+II \/ Type 1+2.<\/p>\n          <div class=\"cnspd-product-meta\">\n            <div><strong>Type:<\/strong> Class I+II \/ Type 1+2<\/div>\n            <div><strong>Ucpv:<\/strong> 1000V DC<\/div>\n            <div><strong>In \/ Imax \/ Iimp:<\/strong> 20kA \/ 40kA \/ 6.25kA<\/div>\n            <div><strong>Certificate:<\/strong> T\u00dcV \/ CE \/ CB<\/div>\n            <div><strong>Buyer:<\/strong> Stocking importer, distributor<\/div>\n          <\/div>\n        <\/div>\n        <a class=\"cnspd-product-link\" href=\"https:\/\/www.cnspd.com\/ly1-c40pv2s1000v-pluggable-dc-spd-product\/\" target=\"_blank\" rel=\"noopener\"><span>View Product<\/span><\/a>\n      <\/div>\n\n      <div class=\"cnspd-product-card\">\n        <div>\n          <span class=\"cnspd-product-tag\">1000V D4 PV SPD<\/span>\n          <div class=\"cnspd-product-image-wrap\">\n            <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2024\/06\/IMG_2043-scaled.jpg\" alt=\"LY1-C40PV3S-1000V D4 PV DC surge protective device product image\" loading=\"lazy\">\n          <\/div>\n          <h3>LY1-C40PV3S-1000V D4<\/h3>\n          <p>For multi-pole PV DC protection designs in combiner boxes and solar inverter cabinets. Class I+II \/ Type 1+2.<\/p>\n          <div class=\"cnspd-product-meta\">\n            <div><strong>Type:<\/strong> Class I+II \/ Type 1+2<\/div>\n            <div><strong>Ucpv:<\/strong> 1000V DC<\/div>\n            <div><strong>In \/ Imax \/ Iimp:<\/strong> 20kA \/ 40kA \/ 6.25kA<\/div>\n            <div><strong>Certificate:<\/strong> Confirm by model scope<\/div>\n            <div><strong>Buyer:<\/strong> Combiner box supplier<\/div>\n          <\/div>\n        <\/div>\n        <a class=\"cnspd-product-link\" href=\"https:\/\/www.cnspd.com\/ly1-c40pv3s1000vd4-pluggable-dc-spd-product\/\" target=\"_blank\" rel=\"noopener\"><span>View Product<\/span><\/a>\n      <\/div>\n\n      <div class=\"cnspd-product-card\">\n        <div>\n          <span class=\"cnspd-product-tag\">1500V PV DC SPD<\/span>\n          <div class=\"cnspd-product-image-wrap\">\n            <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2024\/06\/IMG_2050-scaled.jpg\" alt=\"LY1-C40PV3S-1500V D4 PV DC surge protective device product image\" loading=\"lazy\">\n          <\/div>\n          <h3>LY1-C40PV3S-1500V D4<\/h3>\n          <p>For 1500V commercial and utility-scale PV systems requiring high-voltage Class I+II \/ Type 1+2 DC SPD protection.<\/p>\n          <div class=\"cnspd-product-meta\">\n            <div><strong>Type:<\/strong> Class I+II \/ Type 1+2<\/div>\n            <div><strong>Ucpv:<\/strong> 1500V DC<\/div>\n            <div><strong>In \/ Imax \/ Iimp:<\/strong> 20kA \/ 40kA \/ 6.25kA<\/div>\n            <div><strong>Certificate:<\/strong> T\u00dcV \/ CE<\/div>\n            <div><strong>Buyer:<\/strong> Project supplier, OEM buyer<\/div>\n          <\/div>\n        <\/div>\n        <a class=\"cnspd-product-link\" href=\"https:\/\/www.cnspd.com\/ly1-c40pv3s-1500vd4-pluggable-multi-pole-spd-product\/\" target=\"_blank\" rel=\"noopener\"><span>View Product<\/span><\/a>\n      <\/div>\n    <\/div>\n\n    <div class=\"cnspd-note\">\n      Not sure which model fits your project? Send module Voc, modules per string, minimum design temperature,\n      inverter type, MPPT arrangement, cable length, grounding system, and external lightning protection condition.\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-dark\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Why Solar PV SPDs Matter<\/div>\n      <h2>A Single Surge Event Can Shut Down An Entire PV System<\/h2>\n      <p>\n        Solar PV assets are exposed to lightning, switching surges, grounding instability,\n        long cable runs, and harsh outdoor environments. The real cost is not only SPD replacement \u2014\n        it is inverter failure, power loss, site maintenance, and responsibility after failure.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-card-grid\">\n      <div class=\"cnspd-card\">\n        <h3>Inverter Damage<\/h3>\n        <p>Surge energy can damage inverter components, reduce system uptime, and create expensive replacement costs.<\/p>\n      <\/div>\n      <div class=\"cnspd-card\">\n        <h3>Production Interruption<\/h3>\n        <p>When a PV system stops producing, every hour of downtime becomes a direct financial loss.<\/p>\n      <\/div>\n      <div class=\"cnspd-card\">\n        <h3>Remote Maintenance Cost<\/h3>\n        <p>For utility-scale or remote solar sites, one failure can trigger high inspection, travel, and labor costs.<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Where To Install SPDs<\/div>\n      <h2>Solar PV Surge Protection Positions<\/h2>\n      <p>\n        Solar surge protection is not only one SPD at one position. The correct design depends on the full surge path:\n        PV array, combiner box, inverter, AC distribution, grounding, and monitoring interfaces.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-install-grid\">\n      <div class=\"cnspd-install-card\">\n        <h3>DC Side Protection<\/h3>\n        <ul>\n          <li>PV string input<\/li>\n          <li>PV combiner box<\/li>\n          <li>Inverter DC input<\/li>\n          <li>Long DC cable routes<\/li>\n          <li>600V \/ 1000V \/ 1500V PV DC systems<\/li>\n        <\/ul>\n      <\/div>\n\n      <div class=\"cnspd-install-card\">\n        <h3>AC Side Protection<\/h3>\n        <ul>\n          <li>Inverter AC output<\/li>\n          <li>AC combiner or distribution panel<\/li>\n          <li>Main distribution board<\/li>\n          <li>Grid-side protection coordination<\/li>\n          <li>Building lightning protection interface<\/li>\n        <\/ul>\n      <\/div>\n\n      <div class=\"cnspd-install-card\">\n        <h3>Signal Line Protection<\/h3>\n        <ul>\n          <li>RS485 inverter communication<\/li>\n          <li>Smart meter wiring<\/li>\n          <li>Weather station lines<\/li>\n          <li>Data logger and SCADA interfaces<\/li>\n          <li>Ethernet or control wiring where required<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section id=\"protection-architecture\" class=\"cnspd-section cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Protection Architecture<\/div>\n      <h2>Solar PV Surge Protection Must Be Designed As A System<\/h2>\n      <p>\n        LEEYEE helps solar installers, EPC contractors, wholesalers, combiner box suppliers,\n        and OEM partners build a complete protection path from PV arrays to inverters and AC distribution\n        through the CNSPD technical platform.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-flow\">\n      <div class=\"cnspd-node\"><span>01<\/span><strong>PV Array<\/strong><\/div>\n      <div class=\"cnspd-node\"><span>02<\/span><strong>Array \/ Combiner SPD<\/strong><\/div>\n      <div class=\"cnspd-node\"><span>03<\/span><strong>DC Cable Route<\/strong><\/div>\n      <div class=\"cnspd-node\"><span>04<\/span><strong>Inverter DC SPD<\/strong><\/div>\n      <div class=\"cnspd-node\"><span>05<\/span><strong>Inverter + AC SPD<\/strong><\/div>\n      <div class=\"cnspd-node\"><span>06<\/span><strong>Main Distribution<\/strong><\/div>\n    <\/div>\n\n    <div class=\"cnspd-subflow\">\n      <strong>Communication and monitoring protection<\/strong>\n      <p>\n        Weather stations, smart meters, RS485, Ethernet, data loggers, and SCADA interfaces may also provide\n        a path for surge energy. Use a suitable signal-line SPD where these wired interfaces require protection.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-note\">\n      Equipotential bonding and grounding are not a final device in the chain. They form the common\n      low-impedance discharge path that supports every SPD position in the system.\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Type 1+2 Or Type 2<\/div>\n      <h2>Solar SPD Selection By Lightning Protection Condition<\/h2>\n      <p>\n        The correct SPD type depends on whether partial lightning current can enter the PV electrical system,\n        not simply on whether the site is located in a thunderstorm-prone area.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-table-wrap\">\n      <table class=\"cnspd-data-table\">\n        <thead>\n          <tr>\n            <th>Site Condition<\/th>\n            <th>Main Distribution<\/th>\n            <th>Inverter AC Side<\/th>\n            <th>Inverter DC Side<\/th>\n            <th>Array \/ Combiner Side<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>No external lightning protection system<\/td>\n            <td>Type 2, subject to the building protection design<\/td>\n            <td>Type 2 AC SPD<\/td>\n            <td>Type 2 PV SPD<\/td>\n            <td>Type 2 PV SPD where required by cable length and layout<\/td>\n          <\/tr>\n          <tr>\n            <td>External lightning protection with separation distance maintained<\/td>\n            <td>Type 1 or Type 1+2 at the installation origin according to the building design<\/td>\n            <td>Type 2 AC SPD<\/td>\n            <td>Type 2 PV SPD<\/td>\n            <td>Type 2 PV SPD where required<\/td>\n          <\/tr>\n          <tr>\n            <td>External lightning protection without adequate separation distance<\/td>\n            <td>Type 1+2 according to the lightning protection design<\/td>\n            <td>Type 1+2 AC SPD where lightning current may enter<\/td>\n            <td>Type 1+2 PV SPD where required by the project design<\/td>\n            <td>Type 1+2 PV SPD where required by the project design<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"cnspd-note\">\n      Final selection must be confirmed from the lightning protection concept, separation distance, local regulations,\n      cable routing, grounding system, equipment impulse withstand level, and project risk assessment.\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-two-col\">\n      <div class=\"cnspd-img-card\">\n        <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/05\/Solar-inverter-cabinet-SPD-installation.png\" alt=\"Solar inverter cabinet SPD installation with DC and AC surge protection\">\n      <\/div>\n      <div>\n        <div class=\"cnspd-title\">\n          <div class=\"eyebrow\">Real-World PV Environments<\/div>\n          <h2>Engineered For The Places Where Solar Systems Actually Fail<\/h2>\n          <p>\n            Solar surge protection must survive outdoor cabinets, high temperature, humidity,\n            lightning-prone regions, unstable grounding, and long service cycles.\n          <\/p>\n        <\/div>\n        <ul class=\"cnspd-list\">\n          <li>Utility-scale solar farms exposed to direct and indirect lightning surges<\/li>\n          <li>Commercial rooftop PV systems with long DC cable routes<\/li>\n          <li>Hybrid inverter systems requiring coordinated DC and AC protection<\/li>\n          <li>Remote telecom solar systems where maintenance is expensive<\/li>\n          <li>Coastal, desert, and high-humidity environments with accelerated aging risk<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section-tight cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">PV Applications<\/div>\n      <h2>Supported Solar PV Application Scenarios<\/h2>\n      <p>\n        LEEYEE supports surge protection planning across common PV system types.\n        The key engineering topics below explain how protection is selected and installed inside real PV systems.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-app-tags\">\n      <span>Utility-Scale PV Plants<\/span>\n      <span>Commercial Rooftop Solar<\/span>\n      <span>Hybrid Inverter Systems<\/span>\n      <span>Remote Solar Power Systems<\/span>\n      <span>OEM Solar SPD Projects<\/span>\n      <span>PV Combiner Boxes<\/span>\n      <span>Solar Inverter Cabinets<\/span>\n      <span>AC Distribution Panels<\/span>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Key Solar Protection Topics<\/div>\n      <h2>Explore Critical Solar SPD Selection Topics<\/h2>\n      <p>\n        Use the topics below to review the main installation, wiring, coordination, and selection logic\n        relevant to your PV system.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-topic-grid\">\n      <a class=\"cnspd-topic-card\" href=\"#inverter-cabinet\">\n        <div>\n          <h3>SPD for Solar Inverter Cabinet<\/h3>\n          <p>How to select and install surge protection inside inverter cabinets for DC and AC sides.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#combiner-box\">\n        <div>\n          <h3>PV Combiner Box Surge Protection<\/h3>\n          <p>Protection logic for combiner boxes, DC strings, grounding, and surge current paths.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#type-selection\">\n        <div>\n          <h3>Type 1+2 vs Type 2 SPD for Solar PV<\/h3>\n          <p>Selection logic for lightning risk, site exposure, and coordinated protection levels.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#dc-ac-protection\">\n        <div>\n          <h3>DC \/ AC SPD Coordination<\/h3>\n          <p>Understand why PV systems often require both DC-side and AC-side surge protection.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#wiring-diagram\">\n        <div>\n          <h3>Solar SPD Wiring Layout<\/h3>\n          <p>Typical wiring positions for PV array, combiner box, inverter, AC panel, and grounding.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#long-cable\">\n        <div>\n          <h3>Long Cable And Two-End Protection<\/h3>\n          <p>When long DC cable routes may require SPDs near both the array and the inverter.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#signal-protection\">\n        <div>\n          <h3>Signal And Communication Protection<\/h3>\n          <p>Protection for RS485, Ethernet, monitoring, weather stations, and data loggers.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n\n      <a class=\"cnspd-topic-card\" href=\"#product-selection\">\n        <div>\n          <h3>Solar SPD Product Selection<\/h3>\n          <p>Connect system voltage, installation position, and protection level to the right SPD category.<\/p>\n        <\/div>\n        <span>View Topic \u2193<\/span>\n      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Engineering Details<\/div>\n      <h2>Solar PV Surge Protection Selection Logic<\/h2>\n      <p>\n        These engineering sections explain how solar PV surge protection is selected across inverter cabinets,\n        combiner boxes, DC\/AC sides, wiring layout, and product categories.\n      <\/p>\n    <\/div>\n\n    <div id=\"inverter-cabinet\" class=\"cnspd-topic-detail\">\n      <h3>SPD for Solar Inverter Cabinet<\/h3>\n      <p>\n        Inverter cabinets are one of the most important protection points in a PV system. Surge energy can enter from\n        PV strings on the DC side, from the AC output side, or through grounding and communication paths. A reliable\n        inverter cabinet design should coordinate DC SPD, AC SPD, short grounding paths, and proper disconnector protection.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>DC Input Side<\/strong><span>Protects PV string\/inverter input from induced surge energy.<\/span><\/div>\n        <div><strong>AC Output Side<\/strong><span>Protects inverter output, AC distribution, and grid-side equipment.<\/span><\/div>\n        <div><strong>Cabinet Layout<\/strong><span>Short wiring and direct grounding improve protection performance.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"combiner-box\" class=\"cnspd-topic-detail\">\n      <h3>PV Combiner Box Surge Protection<\/h3>\n      <p>\n        A PV combiner box collects multiple DC string circuits, making it a critical location for surge protection.\n        The SPD should be positioned close to incoming circuits and connected to grounding with short, low-impedance paths.\n        Fuse protection, disconnectors, terminals, and cable routing should be considered together with the SPD.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>String Protection<\/strong><span>Reduces surge stress before energy reaches the inverter.<\/span><\/div>\n        <div><strong>Grounding Path<\/strong><span>Short and direct grounding is essential for effective surge limitation.<\/span><\/div>\n        <div><strong>Outdoor Reliability<\/strong><span>Components must handle heat, humidity, and enclosure conditions.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"type-selection\" class=\"cnspd-topic-detail\">\n      <h3>Type 1+2 vs Type 2 SPD for Solar PV<\/h3>\n      <p>\n        Type 2 PV SPDs are commonly used where protection is mainly required against induced and switching surges.\n        Type 1 or Type 1+2 PV SPDs are required where the lightning protection design indicates that partial lightning\n        current may enter the electrical installation, including certain systems connected to an external lightning\n        protection system without adequate separation distance.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>Type 1+2 PV SPD<\/strong><span>For locations where partial lightning current may enter the PV electrical system.<\/span><\/div>\n        <div><strong>Type 2 PV SPD<\/strong><span>For induced lightning surges and switching transients.<\/span><\/div>\n        <div><strong>Decision Basis<\/strong><span>Use the site lightning protection concept, separation distance, and risk assessment.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"dc-ac-protection\" class=\"cnspd-topic-detail\">\n      <h3>DC \/ AC SPD Coordination<\/h3>\n      <p>\n        Solar PV systems often need protection on both the DC and AC sides. The DC side protects PV arrays,\n        combiner boxes, and inverter input. The AC side protects inverter output, AC panels, distribution boards,\n        and grid-connected equipment. Treating only one side can leave the system exposed.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>DC Side<\/strong><span>PV arrays, strings, combiner boxes, and inverter DC input.<\/span><\/div>\n        <div><strong>AC Side<\/strong><span>Inverter output, AC distribution, and downstream AC equipment.<\/span><\/div>\n        <div><strong>System View<\/strong><span>Protection works best when the full energy path is considered.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"wiring-diagram\" class=\"cnspd-topic-detail\">\n      <h3>Solar SPD Wiring Layout<\/h3>\n      <p>\n        SPD wiring should be short, direct, and coordinated with the cabinet grounding structure. Long wiring increases\n        residual voltage and reduces protection performance. Typical positions include PV combiner boxes, inverter cabinets,\n        AC distribution panels, and grounding bars.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>Short Leads<\/strong><span>Reduce voltage drop and improve surge discharge performance.<\/span><\/div>\n        <div><strong>Correct Position<\/strong><span>Install near protected equipment and incoming surge paths.<\/span><\/div>\n        <div><strong>Grounding Bar<\/strong><span>Ensure a clear, low-impedance path to earth.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"long-cable\" class=\"cnspd-topic-detail\">\n      <h3>Long DC Cable Routes And Two-End SPD Protection<\/h3>\n      <p>\n        An SPD should be installed close to the equipment it protects. When the distance between the PV array,\n        combiner box, and inverter is long, one SPD at only one end may not sufficiently limit the voltage reaching\n        equipment at the opposite end. Around 10 metres is often used as a design assessment point for considering\n        coordinated protection at both ends, but it is not a universal rule for every project.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>Array \/ Combiner End<\/strong><span>Limits surge energy before it travels along the DC cable route.<\/span><\/div>\n        <div><strong>Inverter End<\/strong><span>Provides local protection close to sensitive inverter DC input electronics.<\/span><\/div>\n        <div><strong>Final Decision<\/strong><span>Check cable routing, equipment impulse withstand, SPD coordination, and local standards.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"signal-protection\" class=\"cnspd-topic-detail\">\n      <h3>Signal And Communication Line Surge Protection<\/h3>\n      <p>\n        Surge energy can also enter through wired communication and monitoring interfaces. Where required,\n        use a signal-line SPD matched to the interface, operating voltage, data rate, wiring method, and grounding design.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>RS485 \/ Metering<\/strong><span>Protects inverter communication, smart meters, and monitoring buses.<\/span><\/div>\n        <div><strong>Ethernet \/ Data<\/strong><span>Protects networked data loggers, gateways, and monitoring equipment.<\/span><\/div>\n        <div><strong>Weather \/ SCADA<\/strong><span>Protects external sensors and control interfaces connected by long outdoor cables.<\/span><\/div>\n      <\/div>\n    <\/div>\n\n    <div id=\"product-selection\" class=\"cnspd-topic-detail\">\n      <h3>Solar SPD Product Selection<\/h3>\n      <p>\n        Solar SPD selection should start from the calculated maximum PV string open-circuit voltage at the minimum\n        design temperature, not only the nominal system voltage. Module Voc, modules per string, grounding arrangement,\n        lightning protection condition, cable length, installation position, and required discharge capability must all be checked.\n      <\/p>\n      <div class=\"cnspd-topic-points\">\n        <div><strong>Voltage And Ucpv<\/strong><span>Calculate maximum string Voc and select a suitable Ucpv above that value.<\/span><\/div>\n        <div><strong>Protection Class<\/strong><span>Confirm Type 2 or Type 1+2 from the actual lightning-current exposure.<\/span><\/div>\n        <div><strong>Key Parameters<\/strong><span>Check In, Imax, Iimp, Up, Iscpv, poles, protection mode, backup protection, and remote contact.<\/span><\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Project Information Checklist<\/div>\n      <h2>Information Needed For A Solar SPD Recommendation<\/h2>\n      <p>\n        Clear project data allows the SPD voltage, protection class, discharge capacity, pole configuration,\n        and installation position to be selected more accurately.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-install-grid\">\n      <div class=\"cnspd-install-card\">\n        <h3>PV And Site Information<\/h3>\n        <ul>\n          <li>Module Voc and number of modules per string<\/li>\n          <li>Minimum design temperature and calculated maximum string Voc<\/li>\n          <li>Inverter type, MPPT quantity, and DC input arrangement<\/li>\n          <li>External lightning protection and separation distance<\/li>\n          <li>DC cable length, routing, and installation environment<\/li>\n          <li>Grounding arrangement and AC system type<\/li>\n          <li>RS485, Ethernet, smart meter, or monitoring interfaces<\/li>\n        <\/ul>\n      <\/div>\n\n      <div class=\"cnspd-install-card\">\n        <h3>SPD Parameters To Confirm<\/h3>\n        <ul>\n          <li>Ucpv or maximum continuous operating voltage<\/li>\n          <li>Type 2 or Type 1+2 protection class<\/li>\n          <li>In, Imax, and Iimp where applicable<\/li>\n          <li>Voltage protection level Up<\/li>\n          <li>PV short-circuit withstand capability Iscpv<\/li>\n          <li>Number of poles and protection mode<\/li>\n          <li>Backup protection, pluggable modules, and remote contact<\/li>\n        <\/ul>\n      <\/div>\n\n      <div class=\"cnspd-install-card\">\n        <h3>Documents For Buyer Review<\/h3>\n        <ul>\n          <li>Model datasheet<\/li>\n          <li>Certificate copy and scope sheet<\/li>\n          <li>User manual and wiring reference<\/li>\n          <li>Product label and packaging confirmation<\/li>\n          <li>OEM label and neutral packaging requirement<\/li>\n          <li>Batch inspection and pre-shipment requirement<\/li>\n          <li>Target market or tender documentation requirement<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Certificates And Manufacturer Proof<\/div>\n      <h2>From Certificate Review To Factory-Controlled Supply<\/h2>\n      <p>\n        PV surge protection buyers need more than a catalog. They need model documents, certificate scope confirmation,\n        factory QC, OEM packaging support, and stable batch shipment capability.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-table-wrap\">\n      <table class=\"cnspd-data-table\">\n        <thead>\n          <tr>\n            <th>Buyer Checkpoint<\/th>\n            <th>What To Confirm<\/th>\n            <th>LEEYEE \/ CNSPD Support<\/th>\n            <th>Useful Page<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Certificate scope<\/td>\n            <td>Voltage rating, model series, pole configuration, standard, and certificate validity<\/td>\n            <td>PV 600V T\u00dcV\/CE, PV 1000V T\u00dcV\/CE\/CB, PV 1500V T\u00dcV\/CE documents by scope<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/patents-certificates\/\" target=\"_blank\" rel=\"noopener\">View Certificates<\/a><\/td>\n          <\/tr>\n          <tr>\n            <td>Product documents<\/td>\n            <td>Datasheet, manual, wiring reference, certificate scope, and model-level information<\/td>\n            <td>Technical downloads and model pages for buyer pre-review<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/technical-downloads\/\" target=\"_blank\" rel=\"noopener\">Technical Downloads<\/a><\/td>\n          <\/tr>\n          <tr>\n            <td>Factory trust<\/td>\n            <td>Material inspection, MOV testing, assembly, final QC, label control, and shipment inspection<\/td>\n            <td>Factory and quality-control evidence should support long-term OEM and batch supply<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/factory-quality-control\/\" target=\"_blank\" rel=\"noopener\">Factory & Quality Control<\/a><\/td>\n          <\/tr>\n          <tr>\n            <td>OEM supply<\/td>\n            <td>Neutral packaging, private label, label confirmation, and batch order process<\/td>\n            <td>OEM\/private label support for SPD buyers, importers, and combiner box suppliers<\/td>\n            <td><a href=\"https:\/\/www.cnspd.com\/spd-manufacturer-china\/\" target=\"_blank\" rel=\"noopener\">SPD Manufacturer China<\/a><\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"cnspd-note\">\n      If the Factory & Quality Control page is not published yet, keep this link ready and publish that page next.\n      It will strengthen this solar page, product pages, certificate page, and OEM pages at the same time.\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Built To Protect. Trusted To Last.<\/div>\n      <h2>Manufacturing Trust Comes From What Happens Before Shipment<\/h2>\n      <p>\n        Reliable surge protection is built through material control, component testing,\n        assembly discipline, thermal protection verification, and consistent quality inspection.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-proof-grid\">\n      <div class=\"cnspd-proof\">\n        <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2025\/08\/MOV-and-GDT-tester-11.jpg\" alt=\"MOV and GDT testing for surge protective devices\">\n        <div><strong>MOV \/ GDT Testing<\/strong><p>Component stability verification before SPD assembly.<\/p><\/div>\n      <\/div>\n      <div class=\"cnspd-proof\">\n        <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2025\/08\/Thermal-Stability-Test1.jpg\" alt=\"Thermal disconnector test for SPD safety\">\n        <div><strong>Thermal Protection<\/strong><p>Disconnector performance designed for safe failure indication.<\/p><\/div>\n      <\/div>\n      <div class=\"cnspd-proof\">\n        <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/05\/controlled-assembly-card-800x600-1.webp\" alt=\"SPD production line and controlled assembly\">\n        <div><strong>Controlled Assembly<\/strong><p>Factory process for stable OEM and batch production.<\/p><\/div>\n      <\/div>\n      <div class=\"cnspd-proof\">\n        <img decoding=\"async\" src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/05\/final-qc-testing09-same-image-card-800x600-1.webp\" alt=\"Final quality control inspection for SPD shipment\">\n        <div><strong>Final QC<\/strong><p>Inspection before packaging, labeling, and export shipment.<\/p><\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-white-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">Engineering Resources<\/div>\n      <h2>Download Solar SPD Technical Documents<\/h2>\n      <p>\n        Help your engineering, purchasing, and installation teams confirm the right SPD\n        for solar PV systems with datasheets, user manuals, certificate scope references,\n        wiring support, and model-level selection guidance.\n      <\/p>\n    <\/div>\n\n    <div class=\"cnspd-resource-grid\">\n      <div class=\"cnspd-resource\">\n        <strong>Solar SPD Selection Guide<\/strong>\n        <p>Review voltage rating, Type 1+2 \/ Type 2 selection, Ucpv, In, Imax, Iimp, Up, Iscpv, and installation position.<\/p>\n        <a href=\"https:\/\/www.cnspd.com\/solar-spd\/\" target=\"_blank\" rel=\"noopener noreferrer\">View Technical Guide \u2192<\/a>\n      <\/div>\n      <div class=\"cnspd-resource\">\n        <strong>PV DC SPD Datasheets<\/strong>\n        <p>Download model-level datasheets for 600V, 1000V, and 1500V PV DC surge protective devices.<\/p>\n        <a href=\"https:\/\/www.cnspd.com\/technical-downloads\/\" target=\"_blank\" rel=\"noopener noreferrer\">View Datasheets \u2192<\/a>\n      <\/div>\n      <div class=\"cnspd-resource\">\n        <strong>PV SPD User Manual<\/strong>\n        <p>Installation and product-use reference for LEEYEE PV surge protective devices.<\/p>\n        <a href=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2024\/07\/LEEYEE-User-manual.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download User Manual \u2192<\/a>\n      <\/div>\n      <div class=\"cnspd-resource\">\n        <strong>Certificate Scope Sheet<\/strong>\n        <p>Check certificate coverage by voltage rating and model series before project filing or OEM confirmation.<\/p>\n        <a href=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/07\/leeyee-pv-dc-spd-certificate-scope-sheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download Scope Sheet \u2192<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-section cnspd-blue-bg\">\n  <div class=\"cnspd-container\">\n    <div class=\"cnspd-title center\">\n      <div class=\"eyebrow\">FAQ<\/div>\n      <h2>Solar PV Surge Protection Questions<\/h2>\n    <\/div>\n\n    <div class=\"cnspd-faq\">\n      <details>\n        <summary>Do solar PV systems really need surge protection?<\/summary>\n        <p>Yes. PV systems are exposed to lightning-induced surges, switching transients, long cable routes, and outdoor electrical stress. Proper SPD installation helps protect inverters, combiner boxes, monitoring equipment, and AC distribution systems.<\/p>\n      <\/details>\n\n      <details>\n        <summary>Where should SPDs be installed in a solar PV system?<\/summary>\n        <p>SPDs are commonly installed on the DC side near PV combiner boxes and inverter DC inputs, on the AC side near inverter outputs and distribution panels, and on wired communication lines where required. The final design depends on cable length, grounding, system voltage, external lightning protection, and lightning exposure.<\/p>\n      <\/details>\n\n      <details>\n        <summary>How do I choose 600V, 1000V, or 1500V PV DC SPD?<\/summary>\n        <p>Start from the calculated maximum PV string open-circuit voltage at the minimum design temperature. Select a PV DC SPD with Ucpv \u2265 Uoc,max, then confirm Type 2 or Type 1+2, In, Imax, Iimp where applicable, Up, pole configuration, certificate scope, and installation position.<\/p>\n      <\/details>\n\n      <details>\n        <summary>What SPD is used in a solar inverter cabinet?<\/summary>\n        <p>A solar inverter cabinet may require DC-side SPDs at the inverter input and AC-side SPDs at the output or distribution side. The correct type depends on PV voltage, grounding system, cable length, and lightning exposure.<\/p>\n      <\/details>\n\n      <details>\n        <summary>How should SPDs be installed in a PV combiner box?<\/summary>\n        <p>In a PV combiner box, DC SPDs are typically installed close to the incoming string circuits and connected with short, direct grounding paths. Proper wiring length and grounding are critical for effective surge limitation.<\/p>\n      <\/details>\n\n      <details>\n        <summary>Do solar PV systems need both DC and AC surge protection?<\/summary>\n        <p>Many PV systems require protection on both sides. The DC side protects PV strings, combiner boxes, and inverter input. The AC side protects inverter output, AC panels, distribution boards, and grid-connected equipment.<\/p>\n      <\/details>\n\n      <details>\n        <summary>What is the difference between Type 1+2 and Type 2 solar SPD?<\/summary>\n        <p>Type 2 PV SPDs are commonly used for induced and switching surges. Type 1 or Type 1+2 PV SPDs are used where the lightning protection design indicates that partial lightning current may enter the electrical installation.<\/p>\n      <\/details>\n\n      <details>\n        <summary>When should Type 1+2 SPD be used in solar PV systems?<\/summary>\n        <p>Type 1 or Type 1+2 PV SPD should be considered where partial lightning current may enter the electrical system, such as certain installations connected to an external lightning protection system without adequate separation distance, or where the project risk assessment requires lightning-current discharge capability.<\/p>\n      <\/details>\n\n      <details>\n        <summary>When are SPDs needed at both ends of a PV cable?<\/summary>\n        <p>When the cable between the PV array, combiner box, and inverter is long, coordinated SPDs may be needed near both ends so that each item of equipment has local protection. Around 10 metres is often used as a design assessment point, but the final decision depends on cable routing, equipment withstand level, SPD coordination, and local requirements.<\/p>\n      <\/details>\n\n      <details>\n        <summary>Do RS485, Ethernet, and monitoring lines need surge protection?<\/summary>\n        <p>They may. Wired communication, weather monitoring, smart-meter, and SCADA lines can provide another path for surge energy. Use a signal-line SPD matched to the interface and system design where these lines require protection.<\/p>\n      <\/details>\n\n      <details>\n        <summary>Can lightning damage solar inverters?<\/summary>\n        <p>Yes. Even without a direct strike, induced surges can travel through DC strings, AC lines, communication lines, and grounding systems, damaging inverter electronics and causing system downtime.<\/p>\n      <\/details>\n\n      <details>\n        <summary>Why choose LEEYEE for solar surge protection?<\/summary>\n        <p>LEEYEE is a specialized surge protection and low-voltage protection supplier, trusted for solar PV, power distribution, telecom, industrial, and OEM applications. CNSPD is LEEYEE\u2019s surge protection-focused brand platform, built to help global buyers source reliable SPDs and related low-voltage protection products.<\/p>\n      <\/details>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"cnspd-final\">\n  <div class=\"cnspd-container\">\n    <h2>Protect Your Solar Infrastructure Before Failure Happens<\/h2>\n    <p>\n      Work with LEEYEE to select reliable solar surge protection for PV strings,\n      inverter cabinets, combiner boxes, AC panels, monitoring lines, and OEM electrical protection projects.\n    <\/p>\n    <div class=\"cnspd-final-note\">\n      Send us the module Voc, modules per string, minimum design temperature,\n      inverter type, cable length, grounding arrangement, external lightning protection condition, and cabinet layout.\n      Our team will help you select the right DC, AC, and signal protection architecture.\n    <\/div>\n    <div class=\"cnspd-btns\" style=\"justify-content:center;\">\n      <a class=\"cnspd-btn cnspd-btn-primary leeyee-site-popup-btn\" href=\"javascript:void(0);\"><span>Request Solar SPD Selection<\/span><\/a>\n      <a class=\"cnspd-btn cnspd-btn-outline\" href=\"https:\/\/wa.me\/8619016752865?text=Hello%20LEEYEE%2C%20I%20need%20support%20for%20Solar%20PV%20Surge%20Protection.\" target=\"_blank\" rel=\"noopener\"><span>Talk To Solar SPD Specialists<\/span><\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Do solar PV systems really need surge protection?\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. PV systems are exposed to lightning-induced surges, switching transients, long cable routes, and outdoor electrical stress. Proper SPD installation helps protect inverters, combiner boxes, monitoring equipment, and AC distribution systems.\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Where should SPDs be installed in a solar PV system?\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SPDs are commonly installed on the DC side near PV combiner boxes and inverter DC inputs, on the AC side near inverter outputs and distribution panels, and on wired communication lines where required. The final design depends on cable length, grounding, system voltage, external lightning protection, and lightning exposure.\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"How do I choose 600V, 1000V, or 1500V PV DC SPD?\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Start from the calculated maximum PV string open-circuit voltage at the minimum design temperature. Select a PV DC SPD with Ucpv \u2265 Uoc,max, then confirm Type 2 or Type 1+2, In, Imax, Iimp where applicable, Up, pole configuration, certificate scope, and installation position.\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"What is the difference between Type 1+2 and Type 2 solar SPD?\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Type 2 PV SPDs are commonly used for induced and switching surges. Type 1 or Type 1+2 PV SPDs are used where the lightning protection design indicates that partial lightning current may enter the electrical installation.\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"When are SPDs needed at both ends of a PV cable?\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"When the cable between the PV array, combiner box, and inverter is long, coordinated SPDs may be needed near both ends so that each item of equipment has local protection. Around 10 metres is often used as a design assessment point, but it is not a universal rule.\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Do RS485, Ethernet, and monitoring lines need surge protection?\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Wired communication, weather monitoring, smart-meter, and SCADA lines can provide another path for surge energy. A suitable signal-line SPD may be required depending on the interface and system design.\"}\n    }\n  ]\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"ItemList\",\n  \"name\":\"LEEYEE Solar PV DC SPD Product Range\",\n  \"itemListElement\":[\n    {\n      \"@type\":\"ListItem\",\n      \"position\":1,\n      \"name\":\"LY1-C40PV3S-600V PV DC SPD\",\n      \"url\":\"https:\/\/www.cnspd.com\/ly1-c40pv3s-600v-pluggable-multi-pole-spd-product\/\"\n    },\n    {\n      \"@type\":\"ListItem\",\n      \"position\":2,\n      \"name\":\"LY1-C40PV2S-1000V PV DC SPD\",\n      \"url\":\"https:\/\/www.cnspd.com\/ly1-c40pv2s1000v-pluggable-dc-spd-product\/\"\n    },\n    {\n      \"@type\":\"ListItem\",\n      \"position\":3,\n      \"name\":\"LY1-C40PV3S-1000V D4 PV DC SPD\",\n      \"url\":\"https:\/\/www.cnspd.com\/ly1-c40pv3s1000vd4-pluggable-dc-spd-product\/\"\n    },\n    {\n      \"@type\":\"ListItem\",\n      \"position\":4,\n      \"name\":\"LY1-C40PV3S-1500V D4 PV DC SPD\",\n      \"url\":\"https:\/\/www.cnspd.com\/ly1-c40pv3s-1500vd4-pluggable-multi-pole-spd-product\/\"\n    }\n  ]\n}\n<\/script>\n\n<\/div>\n\n<script>\ndocument.addEventListener(\"DOMContentLoaded\", function () {\n  function openLeeyeePopup(event) {\n    event.preventDefault();\n\n    var popupTrigger =\n      document.querySelector(\".w-popup.ush_popup_1 .w-popup-trigger\") ||\n      document.querySelector(\".ush_popup_1 .w-popup-trigger\") ||\n      document.querySelector('button.w-popup-trigger[aria-label=\"Request Free Quote\"]') ||\n      document.querySelector(\".w-popup-trigger.us-btn-style_12\") ||\n      document.querySelector(\".w-popup-trigger\");\n\n    if (popupTrigger) {\n      popupTrigger.click();\n      return;\n    }\n\n    var popup = document.querySelector(\".w-popup.ush_popup_1, .ush_popup_1.w-popup, .ush_popup_1\");\n    if (popup) {\n      popup.classList.add(\"active\");\n      popup.style.display = \"block\";\n      return;\n    }\n\n    window.location.href = \"\/contact\/\";\n  }\n\n  document.querySelectorAll(\".leeyee-site-popup-btn\").forEach(function (button) {\n    button.addEventListener(\"click\", openLeeyeePopup);\n  });\n});\n<\/script>\n\n<script>\ndocument.addEventListener(\"DOMContentLoaded\", function () {\n  var page = document.querySelector(\".cnspd-solar-page\");\n  if (!page) return;\n\n  var section = page.closest(\".l-section\");\n  if (section) {\n    section.style.setProperty(\"padding-top\", \"0\", \"important\");\n    section.style.setProperty(\"padding-bottom\", \"0\", \"important\");\n    section.style.setProperty(\"margin-bottom\", \"0\", \"important\");\n    section.classList.add(\"cnspd-fixed-outer-section\");\n  }\n\n  var sectionInner = page.closest(\".l-section-h\");\n  if (sectionInner) {\n    sectionInner.style.setProperty(\"padding-top\", \"0\", \"important\");\n    sectionInner.style.setProperty(\"padding-bottom\", \"0\", \"important\");\n    sectionInner.style.setProperty(\"margin-bottom\", \"0\", \"important\");\n    sectionInner.style.setProperty(\"max-width\", \"none\", \"important\");\n    sectionInner.style.setProperty(\"width\", \"100%\", \"important\");\n  }\n\n  var wrappers = page.closest(\".l-section\")\n    ? page.closest(\".l-section\").querySelectorAll(\".vc_row, .vc_column-inner, .wpb_wrapper, .wpb_content_element, .wpb_raw_html\")\n    : [];\n\n  wrappers.forEach(function (el) {\n    el.style.setProperty(\"padding-bottom\", \"0\", \"important\");\n    el.style.setProperty(\"margin-bottom\", \"0\", \"important\");\n  });\n});\n<\/script><\/div><\/div><\/div><\/div><\/div><\/section>\n","protected":false},"excerpt":{"rendered":"Solar PV DC SPD Selection & System Protection Solar PV Surge Protection Guide for DC SPD Selection Select surge protection for PV strings, combiner boxes, inverter DC inputs, inverter AC outputs, distribution panels, and monitoring lines. LEEYEE supplies 600V, 1000V, and 1500V PV DC SPDs for solar PV systems and OEM projects. Request Solar SPD...","protected":false},"author":18,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-29062","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Solar PV Surge Protection - Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE<\/title>\n<meta name=\"description\" content=\"Check out our professional Solar PV Surge Protection at LEEYEE Electrics for Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE .\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cnspd.com\/es\/proteccion-contra-sobretensiones-de-energia-solar-fotovoltaica\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solar PV Surge Protection - Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\" \/>\n<meta property=\"og:description\" content=\"Check out our professional Solar PV Surge Protection at LEEYEE Electrics for Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE .\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cnspd.com\/es\/proteccion-contra-sobretensiones-de-energia-solar-fotovoltaica\/\" \/>\n<meta property=\"og:site_name\" content=\"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-08T03:17:26+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/solar-pv-surge-protection\\\/\",\"url\":\"https:\\\/\\\/www.cnspd.com\\\/solar-pv-surge-protection\\\/\",\"name\":\"Solar PV Surge Protection - Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#website\"},\"datePublished\":\"2026-05-22T08:47:04+00:00\",\"dateModified\":\"2026-07-08T03:17:26+00:00\",\"description\":\"Check out our professional Solar PV Surge Protection at LEEYEE Electrics for Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE .\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/solar-pv-surge-protection\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cnspd.com\\\/solar-pv-surge-protection\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/solar-pv-surge-protection\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.cnspd.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solar PV Surge Protection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#website\",\"url\":\"https:\\\/\\\/www.cnspd.com\\\/\",\"name\":\"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\",\"description\":\"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cnspd.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Protecci\u00f3n contra sobretensiones de energ\u00eda solar fotovoltaica - Protector contra sobretensiones, Pararrayos, Interruptor de aislamiento - LEEYEE","description":"Consulte nuestra protecci\u00f3n contra sobretensiones profesional para paneles solares en LEEYEE Electrics para protector contra sobretensiones, limitador de sobretensiones, interruptor de aislamiento - LEEYEE. .","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cnspd.com\/es\/proteccion-contra-sobretensiones-de-energia-solar-fotovoltaica\/","og_locale":"es_ES","og_type":"article","og_title":"Solar PV Surge Protection - Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE","og_description":"Check out our professional Solar PV Surge Protection at LEEYEE Electrics for Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE .","og_url":"https:\/\/www.cnspd.com\/es\/proteccion-contra-sobretensiones-de-energia-solar-fotovoltaica\/","og_site_name":"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE","article_modified_time":"2026-07-08T03:17:26+00:00","twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.cnspd.com\/solar-pv-surge-protection\/","url":"https:\/\/www.cnspd.com\/solar-pv-surge-protection\/","name":"Protecci\u00f3n contra sobretensiones de energ\u00eda solar fotovoltaica - Protector contra sobretensiones, Pararrayos, Interruptor de aislamiento - LEEYEE","isPartOf":{"@id":"https:\/\/www.cnspd.com\/#website"},"datePublished":"2026-05-22T08:47:04+00:00","dateModified":"2026-07-08T03:17:26+00:00","description":"Consulte nuestra protecci\u00f3n contra sobretensiones profesional para paneles solares en LEEYEE Electrics para protector contra sobretensiones, limitador de sobretensiones, interruptor de aislamiento - LEEYEE. .","breadcrumb":{"@id":"https:\/\/www.cnspd.com\/solar-pv-surge-protection\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cnspd.com\/solar-pv-surge-protection\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.cnspd.com\/solar-pv-surge-protection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.cnspd.com\/"},{"@type":"ListItem","position":2,"name":"Solar PV Surge Protection"}]},{"@type":"WebSite","@id":"https:\/\/www.cnspd.com\/#website","url":"https:\/\/www.cnspd.com\/","name":"Protector contra sobretensiones, supresor de sobretensiones, interruptor de aislamiento - LEEYEE","description":"Protector contra sobretensiones, supresor de sobretensiones, interruptor de aislamiento - LEEYEE","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cnspd.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"}]}},"_links":{"self":[{"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/pages\/29062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/comments?post=29062"}],"version-history":[{"count":18,"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/pages\/29062\/revisions"}],"predecessor-version":[{"id":29866,"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/pages\/29062\/revisions\/29866"}],"wp:attachment":[{"href":"https:\/\/www.cnspd.com\/es\/wp-json\/wp\/v2\/media?parent=29062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}