{"id":31631,"date":"2026-10-12T13:25:41","date_gmt":"2026-10-12T05:25:41","guid":{"rendered":"https:\/\/www.cnspd.com\/?p=31631"},"modified":"2026-10-12T13:46:42","modified_gmt":"2026-10-12T05:46:42","slug":"automatic-transfer-switch-for-inverter-do-you-need-an-external-ats","status":"publish","type":"post","link":"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/","title":{"rendered":"Automatic Transfer Switch for Inverter: Do You Need an External ATS?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"31631\" class=\"elementor elementor-31631\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ea0c6d e-flex e-con-boxed e-con e-parent\" data-id=\"5ea0c6d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-80044d2 elementor-widget elementor-widget-html\" data-id=\"80044d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<style>\r\n#leeyee-inverter-ats-page {\r\n  --ly-blue: #004898;\r\n  --ly-blue-dark: #00396f;\r\n  --ly-blue-soft: #eef5ff;\r\n  --ly-blue-softer: #f7fbff;\r\n  --ly-text: #263746;\r\n  --ly-heading: #172b3a;\r\n  --ly-muted: #667784;\r\n  --ly-border: #dbe5ec;\r\n  --ly-warning-bg: #fff8e9;\r\n  --ly-warning-border: #d99a27;\r\n  --ly-success-bg: #f2faf5;\r\n  --ly-success-border: #39845b;\r\n  width: 100%;\r\n  max-width: 860px;\r\n  margin: 0 auto;\r\n  padding: 8px 20px 64px;\r\n  box-sizing: border-box;\r\n  color: var(--ly-text);\r\n  font-size: 17px;\r\n  line-height: 1.72;\r\n}\r\n\r\n#leeyee-inverter-ats-page *,\r\n#leeyee-inverter-ats-page *::before,\r\n#leeyee-inverter-ats-page *::after {\r\n  box-sizing: border-box;\r\n}\r\n\r\n#leeyee-inverter-ats-page p {\r\n  margin: 0 0 18px;\r\n}\r\n\r\n#leeyee-inverter-ats-page strong {\r\n  color: #1b3040;\r\n  font-weight: 700;\r\n}\r\n\r\n#leeyee-inverter-ats-page a {\r\n  color: var(--ly-blue);\r\n  text-decoration-thickness: 1px;\r\n  text-underline-offset: 3px;\r\n}\r\n\r\n#leeyee-inverter-ats-page a:hover {\r\n  color: var(--ly-blue-dark);\r\n}\r\n\r\n#leeyee-inverter-ats-page h2 {\r\n  margin: 54px 0 18px;\r\n  color: var(--ly-heading);\r\n  font-size: clamp(27px, 3vw, 32px);\r\n  line-height: 1.25;\r\n  letter-spacing: -0.02em;\r\n}\r\n\r\n#leeyee-inverter-ats-page h3 {\r\n  margin: 34px 0 13px;\r\n  color: #203848;\r\n  font-size: clamp(21px, 2.4vw, 24px);\r\n  line-height: 1.32;\r\n}\r\n\r\n#leeyee-inverter-ats-page ul,\r\n#leeyee-inverter-ats-page ol {\r\n  margin: 15px 0 22px;\r\n  padding-left: 24px;\r\n}\r\n\r\n#leeyee-inverter-ats-page li {\r\n  margin: 7px 0;\r\n  padding-left: 3px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-intro {\r\n  margin-bottom: 24px;\r\n  color: #314957;\r\n  font-size: 18px;\r\n  line-height: 1.7;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-answer,\r\n#leeyee-inverter-ats-page .ly-note,\r\n#leeyee-inverter-ats-page .ly-warning,\r\n#leeyee-inverter-ats-page .ly-success,\r\n#leeyee-inverter-ats-page .ly-checklist,\r\n#leeyee-inverter-ats-page .ly-cta {\r\n  border-radius: 12px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-answer {\r\n  margin: 26px 0 31px;\r\n  padding: 23px 25px;\r\n  background: var(--ly-blue-softer);\r\n  border: 1px solid #d7e8f4;\r\n  border-left: 4px solid var(--ly-blue);\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-answer-label {\r\n  display: block;\r\n  margin-bottom: 8px;\r\n  color: var(--ly-blue);\r\n  font-size: 14px;\r\n  font-weight: 800;\r\n  letter-spacing: 0.06em;\r\n  text-transform: uppercase;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-answer p:last-child,\r\n#leeyee-inverter-ats-page .ly-note p:last-child,\r\n#leeyee-inverter-ats-page .ly-warning p:last-child,\r\n#leeyee-inverter-ats-page .ly-success p:last-child,\r\n#leeyee-inverter-ats-page .ly-cta p:last-child {\r\n  margin-bottom: 0;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-note,\r\n#leeyee-inverter-ats-page .ly-warning,\r\n#leeyee-inverter-ats-page .ly-success {\r\n  margin: 24px 0;\r\n  padding: 18px 21px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-note {\r\n  background: var(--ly-blue-softer);\r\n  border: 1px solid #dceaf4;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-warning {\r\n  background: var(--ly-warning-bg);\r\n  border: 1px solid #ecd6a4;\r\n  border-left: 4px solid var(--ly-warning-border);\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-success {\r\n  background: var(--ly-success-bg);\r\n  border: 1px solid #cee7d8;\r\n  border-left: 4px solid var(--ly-success-border);\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-keyline {\r\n  margin: 24px 0;\r\n  padding: 17px 20px;\r\n  background: #fff;\r\n  border-left: 4px solid var(--ly-blue);\r\n  color: #29404e;\r\n  font-weight: 700;\r\n}\r\n\r\n#leeyee-inverter-ats-page figure {\r\n  margin: 30px 0 36px;\r\n}\r\n\r\n#leeyee-inverter-ats-page figure img {\r\n  display: block;\r\n  width: 100%;\r\n  height: auto;\r\n  margin: 0 auto;\r\n  border: 1px solid #e1e9ef;\r\n  border-radius: 12px;\r\n  background: #fff;\r\n}\r\n\r\n#leeyee-inverter-ats-page figure.ly-product-figure img {\r\n  width: min(100%, 640px);\r\n}\r\n\r\n#leeyee-inverter-ats-page figcaption {\r\n  max-width: 760px;\r\n  margin: 10px auto 0;\r\n  color: var(--ly-muted);\r\n  font-size: 14px;\r\n  line-height: 1.55;\r\n  text-align: center;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-table-wrap {\r\n  width: 100%;\r\n  margin: 22px 0 12px;\r\n}\r\n\r\n#leeyee-inverter-ats-page table {\r\n  width: 100%;\r\n  border-collapse: separate;\r\n  border-spacing: 0;\r\n  table-layout: fixed;\r\n  overflow: hidden;\r\n  border: 1px solid var(--ly-border);\r\n  border-radius: 10px;\r\n  background: #fff;\r\n  font-size: 15.5px;\r\n  line-height: 1.5;\r\n}\r\n\r\n#leeyee-inverter-ats-page th,\r\n#leeyee-inverter-ats-page td {\r\n  padding: 13px 14px;\r\n  vertical-align: top;\r\n  overflow-wrap: anywhere;\r\n  border-right: 1px solid var(--ly-border);\r\n  border-bottom: 1px solid var(--ly-border);\r\n}\r\n\r\n#leeyee-inverter-ats-page th:last-child,\r\n#leeyee-inverter-ats-page td:last-child {\r\n  border-right: 0;\r\n}\r\n\r\n#leeyee-inverter-ats-page tr:last-child td {\r\n  border-bottom: 0;\r\n}\r\n\r\n#leeyee-inverter-ats-page th {\r\n  background: var(--ly-blue);\r\n  color: #fff;\r\n  font-size: 14.5px;\r\n  font-weight: 700;\r\n  text-align: left;\r\n}\r\n\r\n#leeyee-inverter-ats-page tbody tr:nth-child(even) td {\r\n  background: #fafcfe;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-table-note {\r\n  margin: 10px 0 0;\r\n  color: var(--ly-muted);\r\n  font-size: 14.5px;\r\n  line-height: 1.6;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-steps {\r\n  margin: 24px 0;\r\n  padding: 0;\r\n  list-style: none;\r\n  counter-reset: ly-step;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-steps li {\r\n  position: relative;\r\n  margin: 0 0 18px;\r\n  padding: 0 0 18px 52px;\r\n  border-bottom: 1px solid #e5edf2;\r\n  counter-increment: ly-step;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-steps li:last-child {\r\n  margin-bottom: 0;\r\n  padding-bottom: 0;\r\n  border-bottom: 0;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-steps li::before {\r\n  content: counter(ly-step);\r\n  position: absolute;\r\n  top: 1px;\r\n  left: 0;\r\n  width: 34px;\r\n  height: 34px;\r\n  border-radius: 50%;\r\n  background: var(--ly-blue);\r\n  color: #fff;\r\n  font-size: 15px;\r\n  font-weight: 800;\r\n  line-height: 34px;\r\n  text-align: center;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-steps strong {\r\n  display: block;\r\n  margin-bottom: 3px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-checklist {\r\n  margin: 23px 0 28px;\r\n  padding: 24px 25px;\r\n  background: var(--ly-blue-softer);\r\n  border: 1px solid #dce8f1;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-checklist ul {\r\n  margin: 0;\r\n  columns: 2;\r\n  column-gap: 35px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-checklist li {\r\n  break-inside: avoid;\r\n  margin-bottom: 9px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-cta {\r\n  margin: 32px 0;\r\n  padding: 25px;\r\n  background: #fff;\r\n  border: 1px solid #d7e3eb;\r\n  box-shadow: 0 8px 24px rgba(24, 58, 81, 0.06);\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-cta p {\r\n  margin-bottom: 17px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .leeyee-about-btn-light.leeyee-site-popup-btn {\r\n  display: inline-flex;\r\n  align-items: center;\r\n  justify-content: center;\r\n  min-height: 50px;\r\n  max-width: 100%;\r\n  margin: 0;\r\n  padding: 11px 25px;\r\n  border: 2px solid #004898;\r\n  border-radius: 10px;\r\n  background: #fff;\r\n  color: #004898;\r\n  box-shadow: 0 4px 12px rgba(0, 72, 152, 0.11);\r\n  appearance: none;\r\n  -webkit-appearance: none;\r\n  cursor: pointer;\r\n  font: inherit;\r\n  font-size: 16px;\r\n  font-weight: 700;\r\n  line-height: 1.25;\r\n  text-align: center;\r\n  text-decoration: none;\r\n  transition:\r\n    background-color 0.18s ease,\r\n    color 0.18s ease,\r\n    transform 0.18s ease,\r\n    box-shadow 0.18s ease;\r\n}\r\n\r\n#leeyee-inverter-ats-page .leeyee-about-btn-light.leeyee-site-popup-btn:hover {\r\n  background: #004898;\r\n  color: #fff;\r\n  transform: translateY(-1px);\r\n  box-shadow: 0 7px 18px rgba(0, 72, 152, 0.17);\r\n}\r\n\r\n#leeyee-inverter-ats-page .leeyee-about-btn-light.leeyee-site-popup-btn:focus-visible {\r\n  outline: 3px solid rgba(0, 72, 152, 0.28);\r\n  outline-offset: 3px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .w-btn-label {\r\n  display: inline-block;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-faq {\r\n  margin-top: 18px;\r\n  border-top: 1px solid #e3eaf0;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-faq-item {\r\n  padding: 22px 0;\r\n  border-bottom: 1px solid #e3eaf0;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-faq-item h3 {\r\n  margin: 0 0 9px;\r\n  font-size: 20px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-faq-item p:last-child {\r\n  margin-bottom: 0;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-related {\r\n  margin: 25px 0 8px;\r\n  padding: 18px 20px;\r\n  background: #fafcfe;\r\n  border-top: 1px solid #e0e9ef;\r\n  border-bottom: 1px solid #e0e9ef;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-related p:last-child {\r\n  margin-bottom: 0;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-references {\r\n  margin-top: 20px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-references ol {\r\n  padding-left: 22px;\r\n}\r\n\r\n#leeyee-inverter-ats-page .ly-references li {\r\n  margin: 11px 0;\r\n  color: #526570;\r\n  font-size: 14.5px;\r\n  line-height: 1.62;\r\n}\r\n\r\n#leeyee-inverter-ats-page sup a {\r\n  font-size: 12px;\r\n  font-weight: 700;\r\n  text-decoration: none;\r\n}\r\n\r\n@media (max-width: 768px) {\r\n  #leeyee-inverter-ats-page {\r\n    padding: 4px 17px 52px;\r\n    font-size: 16px;\r\n    line-height: 1.68;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page h2 {\r\n    margin-top: 44px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page h3 {\r\n    margin-top: 29px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page .ly-answer,\r\n  #leeyee-inverter-ats-page .ly-checklist,\r\n  #leeyee-inverter-ats-page .ly-cta {\r\n    padding: 20px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page .ly-checklist ul {\r\n    columns: 1;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page table,\r\n  #leeyee-inverter-ats-page thead,\r\n  #leeyee-inverter-ats-page tbody,\r\n  #leeyee-inverter-ats-page tr,\r\n  #leeyee-inverter-ats-page th,\r\n  #leeyee-inverter-ats-page td {\r\n    display: block;\r\n    width: 100%;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page thead {\r\n    position: absolute;\r\n    width: 1px;\r\n    height: 1px;\r\n    overflow: hidden;\r\n    clip: rect(0 0 0 0);\r\n    white-space: nowrap;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page table {\r\n    border: 0;\r\n    background: transparent;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page tbody tr {\r\n    margin: 0 0 14px;\r\n    overflow: hidden;\r\n    border: 1px solid var(--ly-border);\r\n    border-radius: 10px;\r\n    background: #fff;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page tbody tr:nth-child(even) td {\r\n    background: #fff;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page td {\r\n    display: grid;\r\n    grid-template-columns: minmax(110px, 36%) 1fr;\r\n    gap: 13px;\r\n    padding: 11px 13px;\r\n    border: 0;\r\n    border-bottom: 1px solid #e6edf2;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page td:last-child {\r\n    border-bottom: 0;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page td::before {\r\n    content: attr(data-label);\r\n    color: var(--ly-blue);\r\n    font-size: 13px;\r\n    font-weight: 800;\r\n    line-height: 1.45;\r\n  }\r\n}\r\n\r\n@media (max-width: 540px) {\r\n  #leeyee-inverter-ats-page {\r\n    padding-left: 15px;\r\n    padding-right: 15px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page .ly-intro {\r\n    font-size: 17px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page figure {\r\n    margin: 25px 0 30px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page figure.ly-product-figure img {\r\n    width: 100%;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page td {\r\n    grid-template-columns: 1fr;\r\n    gap: 4px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page .leeyee-about-btn-light.leeyee-site-popup-btn {\r\n    width: 100%;\r\n    min-height: 50px;\r\n    padding-left: 18px;\r\n    padding-right: 18px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page .ly-steps li {\r\n    padding-left: 46px;\r\n  }\r\n}\r\n\r\n@media (max-width: 390px) {\r\n  #leeyee-inverter-ats-page {\r\n    padding-left: 12px;\r\n    padding-right: 12px;\r\n  }\r\n\r\n  #leeyee-inverter-ats-page .ly-answer,\r\n  #leeyee-inverter-ats-page .ly-note,\r\n  #leeyee-inverter-ats-page .ly-warning,\r\n  #leeyee-inverter-ats-page .ly-success,\r\n  #leeyee-inverter-ats-page .ly-checklist,\r\n  #leeyee-inverter-ats-page .ly-cta {\r\n    padding-left: 17px;\r\n    padding-right: 17px;\r\n  }\r\n}\r\n<\/style>\r\n\r\n<article id=\"leeyee-inverter-ats-page\">\r\n\r\n  <p class=\"ly-intro\">\r\n    Do you need an <strong>automatic transfer switch for an inverter<\/strong>? Not always. Many inverter-chargers and hybrid inverters already include an internal transfer function, a dedicated backup or EPS output, or a manufacturer-specific backup interface. An external ATS becomes useful when the approved system design needs a separate device to transfer a load between two AC sources or provide an additional automatic bypass path.\r\n  <\/p>\r\n\r\n  <div class=\"ly-answer\">\r\n    <span class=\"ly-answer-label\">Quick Answer<\/span>\r\n    <p>\r\n      <strong>Check the inverter manual before selecting an external ATS.<\/strong> If the inverter already provides the required automatic transfer function, another ATS may be unnecessary. If grid AC and inverter AC output must independently supply the same transferred load, or the load needs an automatic alternative path when inverter output is unavailable, an external ATS may be appropriate. The final arrangement must follow the inverter manufacturer's approved wiring diagram and the project's electrical requirements. <sup><a href=\"#ref-2\">[2]<\/a><\/sup><sup><a href=\"#ref-3\">[3]<\/a><\/sup>\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <div class=\"ly-table-wrap\">\r\n    <table aria-label=\"When an inverter backup system may need an external ATS\">\r\n      <thead>\r\n        <tr>\r\n          <th style=\"width:38%;\">Inverter system<\/th>\r\n          <th style=\"width:22%;\">External ATS?<\/th>\r\n          <th style=\"width:40%;\">Main confirmation<\/th>\r\n        <\/tr>\r\n      <\/thead>\r\n      <tbody>\r\n        <tr>\r\n          <td data-label=\"Inverter system\">Inverter with an internal AC transfer function<\/td>\r\n          <td data-label=\"External ATS?\">Often not required<\/td>\r\n          <td data-label=\"Main confirmation\">Confirm that the built-in function meets the required backup operation.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Inverter system\">Hybrid inverter with dedicated EPS \/ backup output<\/td>\r\n          <td data-label=\"External ATS?\">Depends<\/td>\r\n          <td data-label=\"Main confirmation\">Follow the manufacturer's approved backup topology.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Inverter system\">Grid AC and inverter AC can feed the same load<\/td>\r\n          <td data-label=\"External ATS?\">May be required<\/td>\r\n          <td data-label=\"Main confirmation\">Check voltage, current, phase, neutral treatment and transfer logic.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Inverter system\">Backup load needs grid supply if inverter output fails<\/td>\r\n          <td data-label=\"External ATS?\">May be useful<\/td>\r\n          <td data-label=\"Main confirmation\">Confirm that an external bypass arrangement is permitted.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Inverter system\">Battery DC circuit requires switching<\/td>\r\n          <td data-label=\"External ATS?\">Not this AC ATS<\/td>\r\n          <td data-label=\"Main confirmation\">Use a device specifically rated for the DC circuit.<\/td>\r\n        <\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n    <p class=\"ly-table-note\">\r\n      Buyer priority: identify the inverter's existing transfer architecture before choosing ATS current or pole count.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <figure>\r\n    <img fetchpriority=\"high\"\r\n      src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp\"\r\n      alt=\"Inverter backup system diagram showing grid AC and inverter AC output connected to an external ATS and load\"\r\n      width=\"1448\"\r\n      height=\"1086\"\r\n      loading=\"eager\"\r\n      decoding=\"async\">\r\n    <figcaption>\r\n      Typical AC-side concept: battery DC feeds the inverter, while the ATS transfers between eligible AC sources before the load.\r\n    <\/figcaption>\r\n  <\/figure>\r\n\r\n  <div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#does-your-inverter-already-have-a-transfer-function\" >Does your inverter already have a transfer function?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#inverter-ats-wiring-diagram-what-each-connection-means\" >Inverter ATS wiring diagram: what each connection means<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#when-does-an-external-ats-make-sense\" >When does an external ATS make sense?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#when-may-an-external-ats-be-unnecessary\" >When may an external ATS be unnecessary?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#ats-vs-inverter-bypass-vs-ups\" >ATS vs inverter bypass vs UPS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#what-does-open-transition-mean-for-inverter-backup\" >What does open transition mean for inverter backup?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#2p-or-4p-which-leeyee-ats-fits-the-inverter-system\" >2P or 4P: which LEEYEE ATS fits the inverter system?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#how-should-you-size-an-ats-for-an-inverter\" >How should you size an ATS for an inverter?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#what-can-go-wrong-if-the-ats-is-selected-incorrectly\" >What can go wrong if the ATS is selected incorrectly?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#where-the-leeyee-compact-ats-fits\" >Where the LEEYEE compact ATS fits<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#what-should-you-send-before-requesting-an-ats-recommendation\" >What should you send before requesting an ATS recommendation?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#frequently-asked-questions\" >Frequently asked questions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"#\" data-href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/#references\" >References<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"does-your-inverter-already-have-a-transfer-function\"><\/span>Does your inverter already have a transfer function?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    This question should come before amperage, pole count or ATS model selection. Some inverter-chargers already pass acceptable AC input through to their AC output and switch to inverter operation when the incoming AC source is no longer acceptable. Victron documents this operating principle for its MultiPlus inverter-charger family. <sup><a href=\"#ref-2\">[2]<\/a><\/sup>\r\n  <\/p>\r\n\r\n  <p>\r\n    Other hybrid systems use a dedicated external backup device designed by the inverter manufacturer. SMA, for example, documents Backup Select as an automatic transfer switching device intended for specific compatible inverter models rather than as a universal accessory for every inverter. <sup><a href=\"#ref-5\">[5]<\/a><\/sup>\r\n  <\/p>\r\n\r\n  <div class=\"ly-note\">\r\n    <p>\r\n      <strong>Engineering meaning:<\/strong> \u201cHybrid inverter\u201d does not define one universal wiring architecture. Two inverters with similar power ratings can require different transfer, neutral and backup arrangements.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <p>\r\n    Before ordering an ATS, check the inverter manual for terms such as <strong>AC input, AC output, EPS output, backup output, transfer relay, bypass, backup interface<\/strong> and <strong>grid connection<\/strong>.\r\n  <\/p>\r\n\r\n  <figure>\r\n    <img loading=\"lazy\"\r\n      src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/do-i-need-external-ats-for-inverter-flowchart.webp\"\r\n      alt=\"Decision flowchart showing when an inverter backup system may need an external automatic transfer switch\"\r\n      width=\"1448\"\r\n      height=\"1086\"\r\n      loading=\"lazy\"\r\n      decoding=\"async\">\r\n    <figcaption>\r\n      Start with the inverter's existing transfer function. Do not add an external ATS before the approved system architecture is clear.\r\n    <\/figcaption>\r\n  <\/figure>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"inverter-ats-wiring-diagram-what-each-connection-means\"><\/span>Inverter ATS wiring diagram: what each connection means<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    For a typical external ATS application, the key relationship is simple: the ATS transfers the <strong>load between AC sources<\/strong>. It does not normally sit between the battery and inverter in the DC circuit.\r\n  <\/p>\r\n\r\n  <div class=\"ly-table-wrap\">\r\n    <table aria-label=\"Inverter ATS wiring diagram connection roles\">\r\n      <thead>\r\n        <tr>\r\n          <th style=\"width:30%;\">Connection<\/th>\r\n          <th style=\"width:35%;\">Typical role<\/th>\r\n          <th style=\"width:35%;\">What must be verified<\/th>\r\n        <\/tr>\r\n      <\/thead>\r\n      <tbody>\r\n        <tr>\r\n          <td data-label=\"Connection\">Grid AC \u2192 ATS<\/td>\r\n          <td data-label=\"Typical role\">One transferable AC source<\/td>\r\n          <td data-label=\"What must be verified\">Voltage, frequency, phase and protective device.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Connection\">Inverter AC output \u2192 ATS<\/td>\r\n          <td data-label=\"Typical role\">Alternate AC source<\/td>\r\n          <td data-label=\"What must be verified\">Approved output, current capability and inverter operating mode.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Connection\">ATS output \u2192 load<\/td>\r\n          <td data-label=\"Typical role\">Transferred load circuit<\/td>\r\n          <td data-label=\"What must be verified\">Maximum load current and required continuity.<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Connection\">Battery DC \u2192 inverter<\/td>\r\n          <td data-label=\"Typical role\">DC energy source<\/td>\r\n          <td data-label=\"What must be verified\">Battery-system DC protection and isolation requirements.<\/td>\r\n        <\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <div class=\"ly-warning\">\r\n    <p>\r\n      <strong>This is an architecture explanation, not a universal terminal wiring instruction.<\/strong> Terminal numbering, neutral connections, protective devices and control wiring must follow the exact ATS documentation, inverter manual and approved project diagram.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"when-does-an-external-ats-make-sense\"><\/span>When does an external ATS make sense?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <h3>Two independent AC sources must feed one transferred load<\/h3>\r\n\r\n  <p>\r\n    This is the clearest ATS application. If grid AC and inverter AC output are both intended to supply the same load at different times, the system needs a controlled transfer arrangement rather than an unintended connection between the sources.\r\n  <\/p>\r\n\r\n  <h3>The inverter does not provide the required automatic changeover<\/h3>\r\n\r\n  <p>\r\n    An external ATS may provide the source-selection function when the inverter itself does not. This still requires confirmation that the inverter manufacturer permits the proposed topology.\r\n  <\/p>\r\n\r\n  <h3>The load needs a fallback path when inverter output fails<\/h3>\r\n\r\n  <p>\r\n    An external ATS can also serve a different purpose: protecting the load against loss of the inverter's backup output. Solis documents a model-specific application where an external ATS transfers backup loads to the grid if an inverter fault or alarm causes the backup output to shut down. <sup><a href=\"#ref-3\">[3]<\/a><\/sup>\r\n  <\/p>\r\n\r\n  <p>\r\n    That Solis arrangement is useful as an engineering example, but it must not be copied blindly to other inverter brands or models.\r\n  <\/p>\r\n\r\n  <h3>The panel builder needs an independent transfer function<\/h3>\r\n\r\n  <p>\r\n    For solar EPCs, system integrators and control-panel manufacturers, a separate ATS may be appropriate when the project's one-line design intentionally separates the source-transfer function from the inverter. The electrical design should be confirmed before the panel BOM is frozen.\r\n  <\/p>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"when-may-an-external-ats-be-unnecessary\"><\/span>When may an external ATS be unnecessary?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    An additional ATS may add no useful function when the inverter already provides the approved source-transfer behaviour required by the project.\r\n  <\/p>\r\n\r\n  <ul>\r\n    <li>The inverter already has a suitable internal AC transfer relay.<\/li>\r\n    <li>A dedicated EPS or backup output already supplies the required backup loads.<\/li>\r\n    <li>The manufacturer specifies its own backup interface or transfer device.<\/li>\r\n    <li>The proposed external ATS would duplicate an existing transfer path without solving another system requirement.<\/li>\r\n  <\/ul>\r\n\r\n  <div class=\"ly-success\">\r\n    <p>\r\n      <strong>Buyer meaning:<\/strong> do not treat an ATS as a mandatory inverter accessory. First identify what transfer function already exists and what additional problem the external ATS is expected to solve.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"ats-vs-inverter-bypass-vs-ups\"><\/span>ATS vs inverter bypass vs UPS<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <div class=\"ly-table-wrap\">\r\n    <table aria-label=\"ATS inverter bypass UPS and battery disconnect comparison\">\r\n      <thead>\r\n        <tr>\r\n          <th style=\"width:25%;\">Function<\/th>\r\n          <th style=\"width:39%;\">Main job<\/th>\r\n          <th style=\"width:36%;\">Buyer question<\/th>\r\n        <\/tr>\r\n      <\/thead>\r\n      <tbody>\r\n        <tr>\r\n          <td data-label=\"Function\"><strong>ATS<\/strong><\/td>\r\n          <td data-label=\"Main job\">Transfers a load between two eligible power sources.<\/td>\r\n          <td data-label=\"Buyer question\">Which AC sources, current, voltage and poles?<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Function\"><strong>Inverter bypass<\/strong><\/td>\r\n          <td data-label=\"Main job\">Routes power around part or all of the inverter conversion path, depending on equipment design.<\/td>\r\n          <td data-label=\"Buyer question\">Is the bypass internal, manual, automatic or external?<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Function\"><strong>UPS function<\/strong><\/td>\r\n          <td data-label=\"Main job\">Maintains specified load supply through a defined energy-storage and power-conversion architecture.<\/td>\r\n          <td data-label=\"Buyer question\">What interruption can the load tolerate?<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td data-label=\"Function\"><strong>Battery disconnect<\/strong><\/td>\r\n          <td data-label=\"Main job\">Switches or isolates a DC battery circuit.<\/td>\r\n          <td data-label=\"Buyer question\">What DC voltage, current and breaking duty apply?<\/td>\r\n        <\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <p>\r\n    Solis specifically distinguishes its integrated manual bypass from an optional external automatic transfer arrangement in its documented application. This is a good example of why \u201cbypass\u201d and \u201cATS\u201d should not automatically be treated as the same function. <sup><a href=\"#ref-3\">[3]<\/a><\/sup>\r\n  <\/p>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"what-does-open-transition-mean-for-inverter-backup\"><\/span>What does open transition mean for inverter backup?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    The standard compact LEEYEE ATS discussed on this page is an <strong>open-transition<\/strong> device. Open transition means <strong>break before make<\/strong>: the connected source is disconnected before the alternate source is connected.\r\n  <\/p>\r\n\r\n  <figure>\r\n    <img loading=\"lazy\"\r\n      src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/open-transition-ats-inverter-transfer-sequence.webp\"\r\n      alt=\"Open transition ATS sequence showing source A disconnecting before source B connects in an inverter backup system\"\r\n      width=\"1448\"\r\n      height=\"1086\"\r\n      loading=\"lazy\"\r\n      decoding=\"async\">\r\n    <figcaption>\r\n      Open transition prevents intentional overlap of the two source connections, but it introduces a transfer interval.\r\n    <\/figcaption>\r\n  <\/figure>\r\n\r\n  <p>\r\n    This means a standard open-transition ATS should not be presented as a zero-interruption UPS solution. The load's ability to tolerate the transfer interval must be checked against the actual ATS performance, inverter behaviour and load requirement.\r\n  <\/p>\r\n\r\n  <div class=\"ly-warning\">\r\n    <p>\r\n      <strong>For sensitive loads:<\/strong> if the project specifies seamless transfer, a defined maximum interruption time or closed-transition operation, confirm that requirement before selecting the ATS. Do not infer those capabilities from the words \u201cautomatic transfer switch.\u201d\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"2p-or-4p-which-leeyee-ats-fits-the-inverter-system\"><\/span>2P or 4P: which LEEYEE ATS fits the inverter system?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    The LEEYEE compact ATS models shown for this application include <strong>2P and 4P configurations<\/strong>. Pole selection is not simply a matter of reading the number of phases. The main engineering question is whether the neutral conductor must be switched together with the live conductors.\r\n  <\/p>\r\n\r\n  <p>\r\n    A single-phase project may use a 2P arrangement where line and neutral are switched. A three-phase project may use a 4P arrangement where L1, L2, L3 and neutral are switched. The final decision must still follow the inverter topology, earthing arrangement, neutral treatment, applicable project rules and the inverter manufacturer's approved connection method.\r\n  <\/p>\r\n\r\n  <figure>\r\n    <img loading=\"lazy\"\r\n      src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-ats-2p-4p-pole-selection-diagram.webp\"\r\n      alt=\"2P and 4P ATS pole selection diagram for single-phase and three-phase inverter backup systems\"\r\n      width=\"1448\"\r\n      height=\"1086\"\r\n      loading=\"lazy\"\r\n      decoding=\"async\">\r\n    <figcaption>\r\n      For the LEEYEE compact ATS configurations shown here, 2P and 4P selection should follow the required conductor-switching scheme, especially the treatment of neutral.\r\n    <\/figcaption>\r\n  <\/figure>\r\n\r\n  <p>\r\n    Neutral switching cannot be decided from phase count alone. Manufacturer-specific backup systems demonstrate this clearly. SMA documents one Backup Select design in which the neutral conductor is not switched, showing why neutral treatment must follow the approved system architecture rather than a universal inverter rule. <sup><a href=\"#ref-5\">[5]<\/a><\/sup>\r\n  <\/p>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"how-should-you-size-an-ats-for-an-inverter\"><\/span>How should you size an ATS for an inverter?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    Do not select the ATS from PV-array wattage alone. The ATS carries the current flowing through the transfer point. The relevant values are the AC source capability, transferred-load current and the project's protective-device and short-circuit design.\r\n  <\/p>\r\n\r\n  <ol class=\"ly-steps\">\r\n    <li>\r\n      <strong>Confirm the inverter architecture.<\/strong>\r\n      Identify AC input, AC output, EPS or backup output, internal transfer function and any manufacturer-specific interface.\r\n    <\/li>\r\n    <li>\r\n      <strong>Confirm both proposed AC sources.<\/strong>\r\n      Check voltage, frequency, phase configuration and whether the sources are permitted in the intended transfer topology.\r\n    <\/li>\r\n    <li>\r\n      <strong>Determine maximum transferred current.<\/strong>\r\n      Review inverter AC output or pass-through limits together with the actual load design current.\r\n    <\/li>\r\n    <li>\r\n      <strong>Select the required 2P or 4P arrangement.<\/strong>\r\n      Determine whether neutral switching is required and confirm that the chosen LEEYEE model matches the approved conductor arrangement.\r\n    <\/li>\r\n    <li>\r\n      <strong>Confirm transfer behaviour.<\/strong>\r\n      Make sure open transition is acceptable for the connected load.\r\n    <\/li>\r\n    <li>\r\n      <strong>Verify protection and fault conditions.<\/strong>\r\n      Coordinate the ATS with upstream and downstream protection and the prospective short-circuit conditions.\r\n    <\/li>\r\n    <li>\r\n      <strong>Approve the one-line diagram before ordering.<\/strong>\r\n      For inverter projects, \u201ccurrent + poles\u201d is not enough information for reliable ATS selection.\r\n    <\/li>\r\n  <\/ol>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"what-can-go-wrong-if-the-ats-is-selected-incorrectly\"><\/span>What can go wrong if the ATS is selected incorrectly?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <ul>\r\n    <li><strong>Wrong system topology:<\/strong> the ATS arrangement can conflict with the inverter's approved transfer or backup logic.<\/li>\r\n    <li><strong>Incorrect neutral treatment:<\/strong> unnecessary or missing neutral switching can affect the intended earthing arrangement.<\/li>\r\n    <li><strong>Unexpected interruption:<\/strong> an open-transition ATS may not suit sensitive loads that require another continuity level.<\/li>\r\n    <li><strong>Wrong current basis:<\/strong> PV or inverter kW alone does not define the actual current through the transfer point.<\/li>\r\n    <li><strong>Incorrect bypass assumption:<\/strong> a general ATS should not automatically replace a manufacturer-specific backup interface.<\/li>\r\n    <li><strong>DC misuse:<\/strong> an AC ATS should not be inserted into a battery DC circuit without a specific approved DC rating.<\/li>\r\n  <\/ul>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"where-the-leeyee-compact-ats-fits\"><\/span>Where the LEEYEE compact ATS fits<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <p>\r\n    The LEEYEE product shown below is a <strong>compact dual-source low-voltage AC automatic transfer switch<\/strong>. The pictured units are marked <strong>ATS-2P63<\/strong> and <strong>ATS-4P63<\/strong> and include A\/B source connections, load output, Auto\/Manual operation and front status indication.\r\n  <\/p>\r\n\r\n  <figure class=\"ly-product-figure\">\r\n    <img loading=\"lazy\"\r\n      src=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/06\/2.png\"\r\n      alt=\"LEEYEE ATS-2P63 and ATS-4P63 compact automatic transfer switches for dual-source AC backup systems\"\r\n      width=\"800\"\r\n      height=\"800\"\r\n      loading=\"lazy\"\r\n      decoding=\"async\">\r\n    <figcaption>\r\n      Actual LEEYEE compact ATS product example. The image shows 2P and 4P units with A\/B source inputs, load output and Auto\/Manual operation.\r\n    <\/figcaption>\r\n  <\/figure>\r\n\r\n  <p>\r\n    In an inverter backup application, one eligible AC source may be the grid and the other may be the inverter AC output, <strong>provided that the inverter manufacturer permits that topology and the electrical ratings are suitable<\/strong>. The product should therefore be evaluated as a dual-source AC transfer device rather than described as a dedicated \u201csolar inverter ATS.\u201d\r\n  <\/p>\r\n\r\n  <div class=\"ly-note\">\r\n    <p>\r\n      <strong>Important:<\/strong> the front markings and A\/B source labels shown on the product image should not be used to assume a universal source priority or terminal assignment for every inverter project. Confirm source priority, control logic and terminal functions from the exact LEEYEE model documentation before wiring.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <p>\r\n    The standard LEEYEE ATS discussed here should not be described as a battery DC switch, UPS, zero-interruption static transfer switch, closed-transition ATS or large bypass-isolation cabinet.\r\n  <\/p>\r\n\r\n  <div class=\"ly-note\">\r\n    <p>\r\n      <strong>Project confirmation:<\/strong> compatibility with a particular inverter brand or model is not assumed. The inverter manual, approved wiring diagram, source voltage, load current, phase configuration and neutral requirement should be reviewed before final ATS selection.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <div class=\"ly-related\">\r\n    <p>\r\n      <strong>Related reading:<\/strong>\r\n      If you need the basic ATS operating principle before reviewing an inverter application, see\r\n      <a href=\"https:\/\/www.cnspd.com\/what-is-an-automatic-transfer-switch-how-ats-works-how-to-choose\/\">\r\n        What Is an Automatic Transfer Switch? How ATS Works &amp; How to Choose\r\n      <\/a>.\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"what-should-you-send-before-requesting-an-ats-recommendation\"><\/span>What should you send before requesting an ATS recommendation?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <div class=\"ly-checklist\">\r\n    <ul>\r\n      <li>Inverter manufacturer and exact model<\/li>\r\n      <li>Inverter manual or wiring diagram<\/li>\r\n      <li>Grid AC voltage and frequency<\/li>\r\n      <li>Inverter AC \/ EPS output voltage<\/li>\r\n      <li>Single-phase or three-phase system<\/li>\r\n      <li>Maximum inverter output or pass-through current<\/li>\r\n      <li>Maximum transferred load current<\/li>\r\n      <li>Required 2P or 4P configuration<\/li>\r\n      <li>Earthing and neutral-switching requirement<\/li>\r\n      <li>Required transfer behaviour<\/li>\r\n      <li>Applicable project standard or approval requirement<\/li>\r\n      <li>Quantity and OEM \/ private-label requirement<\/li>\r\n    <\/ul>\r\n  <\/div>\r\n\r\n  <div class=\"ly-cta\">\r\n    <p>\r\n      <strong>Need to confirm whether a LEEYEE compact ATS fits your inverter system?<\/strong><br>\r\n      Send the inverter model, wiring diagram, AC voltage, phase configuration and expected transferred current. LEEYEE can review the AC transfer requirement before model selection.\r\n    <\/p>\r\n\r\n    <button type=\"button\"\r\n            class=\"leeyee-about-btn-light leeyee-site-popup-btn\"\r\n            aria-label=\"Request ATS Selection Help\">\r\n      <span class=\"w-btn-label\">Request ATS Selection Help<\/span>\r\n    <\/button>\r\n  <\/div>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"frequently-asked-questions\"><\/span>Frequently asked questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <div class=\"ly-faq\">\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Do I need an ATS if my inverter already has a transfer switch?<\/h3>\r\n      <p>\r\n        Not necessarily. If the inverter's built-in transfer function already performs the required source changeover and supports the intended load arrangement, another ATS may be unnecessary. Check the inverter manual before adding an external transfer device. <sup><a href=\"#ref-2\">[2]<\/a><\/sup>\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Can a LEEYEE ATS switch between grid power and inverter output?<\/h3>\r\n      <p>\r\n        It may be used for that AC source-transfer function when the inverter manufacturer permits the architecture and the selected ATS model matches the required voltage, current, pole configuration and transfer behaviour. Do not assume compatibility from source type alone.\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Does every hybrid inverter need an external ATS?<\/h3>\r\n      <p>\r\n        No. Some systems have internal source transfer, while others use a dedicated manufacturer-specific backup device or may require an external transfer arrangement. The approved inverter documentation should determine the starting point. <sup><a href=\"#ref-2\">[2]<\/a><\/sup><sup><a href=\"#ref-5\">[5]<\/a><\/sup>\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Can an ATS automatically bypass a failed inverter?<\/h3>\r\n      <p>\r\n        It can in a system specifically designed for that function. Solis documents one inverter-specific configuration where an external ATS transfers backup loads to grid power if inverter backup output is lost. That example should not be treated as a universal wiring method for all inverters. <sup><a href=\"#ref-3\">[3]<\/a><\/sup>\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Can I connect the battery directly to this ATS?<\/h3>\r\n      <p>\r\n        Not for the AC application discussed on this page. The battery circuit is DC and requires switching and protection equipment specifically rated for its DC voltage, current and breaking duty.\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Is inverter bypass the same as an ATS?<\/h3>\r\n      <p>\r\n        No. An ATS selects between eligible power sources. An inverter bypass routes power around part or all of the inverter path according to the equipment design. A particular backup system may use both functions, but they are not automatically interchangeable.\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Does an open-transition ATS provide zero-interruption transfer?<\/h3>\r\n      <p>\r\n        No such assumption should be made. Open transition is break-before-make and includes a transfer interval. If the connected load requires a defined maximum interruption time or seamless continuity, that requirement must be verified separately.\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Should I choose the 2P or 4P LEEYEE ATS?<\/h3>\r\n      <p>\r\n        The choice depends on the phase arrangement and whether the neutral must be switched. A 2P unit may suit a single-phase arrangement where line and neutral are transferred, while a 4P unit may suit a three-phase arrangement requiring L1, L2, L3 and neutral transfer. Confirm the inverter topology and neutral requirement before ordering.\r\n      <\/p>\r\n    <\/div>\r\n\r\n    <div class=\"ly-faq-item\">\r\n      <h3>Should ATS size be selected from inverter kW?<\/h3>\r\n      <p>\r\n        Not from kW alone. Determine the maximum AC current that can actually flow through the transfer point and confirm it against the ATS rating, load design and protection requirements.\r\n      <\/p>\r\n    <\/div>\r\n\r\n  <\/div>\r\n\r\n  <h2><span class=\"ez-toc-section\" id=\"references\"><\/span>References<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n  <div class=\"ly-references\">\r\n    <ol>\r\n      <li id=\"ref-1\">\r\n        International Electrotechnical Commission (IEC).\r\n        <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/90494\" target=\"_blank\" rel=\"noopener\">\r\n          IEC 60947-6-1:2026 \u2014 Low-voltage switchgear and controlgear \u2014 Part 6-1: Multiple function equipment \u2014 Transfer switching equipment\r\n        <\/a>.\r\n        Use the applicable edition and model-specific manufacturer documentation for project approval.\r\n      <\/li>\r\n\r\n      <li id=\"ref-2\">\r\n        Victron Energy.\r\n        <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/MultiPlus_2kVA_230V\/en\/operation.html\" target=\"_blank\" rel=\"noopener\">\r\n          MultiPlus 2kVA 230V \u2014 Operation\r\n        <\/a>.\r\n        Official documentation describing AC input passthrough and inverter operation when incoming AC is not within specification.\r\n      <\/li>\r\n\r\n      <li id=\"ref-3\">\r\n        Solis North America.\r\n        <a href=\"https:\/\/usservice.solisinverters.com\/support\/solutions\/articles\/73000661699-external-automatic-transfer-switch-ats-for-backup-load-protection\" target=\"_blank\" rel=\"noopener\">\r\n          External Automatic Transfer Switch (ATS) for Backup Load Protection\r\n        <\/a>.\r\n        Model-specific guidance showing an external ATS used to transfer backup loads to grid if inverter backup output is unavailable.\r\n      <\/li>\r\n\r\n      <li id=\"ref-4\">\r\n        SolarEdge.\r\n        Official Backup Interface documentation and installation instructions for compatible SolarEdge backup systems. Verify the current manual and compatible inverter\/battery combination for the specific project.\r\n      <\/li>\r\n\r\n      <li id=\"ref-5\">\r\n        SMA Solar Technology AG.\r\n        <a href=\"https:\/\/manuals.sma.de\/BU-SLCT-US-50\/en-US\/14746045451.html\" target=\"_blank\" rel=\"noopener\">\r\n          SMA Backup Select \u2014 Intended Use\r\n        <\/a>.\r\n        Official documentation describing a manufacturer-specific automatic transfer switching device and its approved conductor arrangement.\r\n      <\/li>\r\n\r\n      <li id=\"ref-6\">\r\n        LEEYEE.\r\n        <a href=\"https:\/\/www.cnspd.com\/what-is-an-automatic-transfer-switch-how-ats-works-how-to-choose\/\">\r\n          What Is an Automatic Transfer Switch? How ATS Works &amp; How to Choose\r\n        <\/a>.\r\n        Supporting overview of ATS operating principles and general source-transfer selection.\r\n      <\/li>\r\n    <\/ol>\r\n  <\/div>\r\n\r\n<\/article>\r\n\r\n<script>\r\ndocument.addEventListener('DOMContentLoaded', function () {\r\n  var aboutPopupButtons = document.querySelectorAll('.leeyee-site-popup-btn');\r\n\r\n  aboutPopupButtons.forEach(function (button) {\r\n    button.addEventListener('click', function () {\r\n      var realPopupTrigger = document.querySelector(\r\n        '.w-popup.ush_popup_1 .w-popup-trigger'\r\n      );\r\n\r\n      if (realPopupTrigger) {\r\n        realPopupTrigger.click();\r\n      } else {\r\n        window.open(\r\n          'https:\/\/www.cnspd.com\/contact\/',\r\n          '_blank',\r\n          'noopener'\r\n        );\r\n      }\r\n    });\r\n  });\r\n});\r\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Do you need an automatic transfer switch for an inverter? Not always. Many inverter-chargers and hybrid inverters already include an internal transfer function, a dedicated backup or EPS output, or a manufacturer-specific backup interface. An external ATS becomes useful when the approved system design needs a separate device to transfer a load between two AC&#8230;<\/p>","protected":false},"author":18,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[490,1,422],"tags":[],"class_list":["post-31631","post","type-post","status-publish","format-standard","hentry","category-isolator-switching","category-news","category-industry-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Automatic Transfer Switch for Inverter: ATS Selection Guide<\/title>\n<meta name=\"description\" content=\"Learn when an inverter needs an external automatic transfer switch, how grid and inverter AC sources are connected, and how to select a 2P or 4P ATS for an inverter backup system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Automatic Transfer Switch for Inverter: ATS Selection Guide\" \/>\n<meta property=\"og:description\" content=\"Learn when an inverter needs an external automatic transfer switch, how grid and inverter AC sources are connected, and how to select a 2P or 4P ATS for an inverter backup system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/\" \/>\n<meta property=\"og:site_name\" content=\"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-12T05:25:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-12T05:46:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp\" \/>\n<meta name=\"author\" content=\"Devin Ling\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ditulis oleh\" \/>\n\t<meta name=\"twitter:data1\" content=\"Devin Ling\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/\"},\"author\":{\"name\":\"Devin Ling\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#\\\/schema\\\/person\\\/f49dbafe62c5b47100ad2d9f88af92d3\"},\"headline\":\"Automatic Transfer Switch for Inverter: Do You Need an External ATS?\",\"datePublished\":\"2026-10-12T05:25:41+00:00\",\"dateModified\":\"2026-10-12T05:46:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/\"},\"wordCount\":2575,\"image\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cnspd.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/inverter-backup-system-external-ats-diagram.webp\",\"articleSection\":[\"Isolator &amp; Switching\",\"News\",\"Technical Guides\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/\",\"url\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/\",\"name\":\"Automatic Transfer Switch for Inverter: ATS Selection Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cnspd.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/inverter-backup-system-external-ats-diagram.webp\",\"datePublished\":\"2026-10-12T05:25:41+00:00\",\"dateModified\":\"2026-10-12T05:46:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#\\\/schema\\\/person\\\/f49dbafe62c5b47100ad2d9f88af92d3\"},\"description\":\"Learn when an inverter needs an external automatic transfer switch, how grid and inverter AC sources are connected, and how to select a 2P or 4P ATS for an inverter backup system.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.cnspd.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/inverter-backup-system-external-ats-diagram.webp\",\"contentUrl\":\"https:\\\/\\\/www.cnspd.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/inverter-backup-system-external-ats-diagram.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/automatic-transfer-switch-for-inverter\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.cnspd.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Automatic Transfer Switch for Inverter: Do You Need an External ATS?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#website\",\"url\":\"https:\\\/\\\/www.cnspd.com\\\/\",\"name\":\"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\",\"description\":\"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cnspd.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.cnspd.com\\\/#\\\/schema\\\/person\\\/f49dbafe62c5b47100ad2d9f88af92d3\",\"name\":\"Devin Ling\",\"sameAs\":[\"https:\\\/\\\/cnspd.com\\\/\"],\"url\":\"https:\\\/\\\/www.cnspd.com\\\/id\\\/author\\\/devin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Automatic Transfer Switch for Inverter: ATS Selection Guide","description":"Learn when an inverter needs an external automatic transfer switch, how grid and inverter AC sources are connected, and how to select a 2P or 4P ATS for an inverter backup system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/","og_locale":"id_ID","og_type":"article","og_title":"Automatic Transfer Switch for Inverter: ATS Selection Guide","og_description":"Learn when an inverter needs an external automatic transfer switch, how grid and inverter AC sources are connected, and how to select a 2P or 4P ATS for an inverter backup system.","og_url":"https:\/\/www.cnspd.com\/id\/automatic-transfer-switch-for-inverter\/","og_site_name":"Surge Protector, Surge Arrestor, Isolating Switch - LEEYEE","article_published_time":"2026-10-12T05:25:41+00:00","article_modified_time":"2026-10-12T05:46:42+00:00","og_image":[{"url":"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp","type":"","width":"","height":""}],"author":"Devin Ling","twitter_card":"summary_large_image","twitter_misc":{"Ditulis oleh":"Devin Ling","Estimasi waktu membaca":"13 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#article","isPartOf":{"@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/"},"author":{"name":"Devin Ling","@id":"https:\/\/www.cnspd.com\/#\/schema\/person\/f49dbafe62c5b47100ad2d9f88af92d3"},"headline":"Automatic Transfer Switch for Inverter: Do You Need an External ATS?","datePublished":"2026-10-12T05:25:41+00:00","dateModified":"2026-10-12T05:46:42+00:00","mainEntityOfPage":{"@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/"},"wordCount":2575,"image":{"@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp","articleSection":["Isolator &amp; Switching","News","Technical Guides"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/","url":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/","name":"Automatic Transfer Switch for Inverter: ATS Selection Guide","isPartOf":{"@id":"https:\/\/www.cnspd.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#primaryimage"},"image":{"@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp","datePublished":"2026-10-12T05:25:41+00:00","dateModified":"2026-10-12T05:46:42+00:00","author":{"@id":"https:\/\/www.cnspd.com\/#\/schema\/person\/f49dbafe62c5b47100ad2d9f88af92d3"},"description":"Learn when an inverter needs an external automatic transfer switch, how grid and inverter AC sources are connected, and how to select a 2P or 4P ATS for an inverter backup system.","breadcrumb":{"@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#primaryimage","url":"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp","contentUrl":"https:\/\/www.cnspd.com\/wp-content\/uploads\/2026\/09\/inverter-backup-system-external-ats-diagram.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.cnspd.com\/automatic-transfer-switch-for-inverter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.cnspd.com\/"},{"@type":"ListItem","position":2,"name":"Automatic Transfer Switch for Inverter: Do You Need an External ATS?"}]},{"@type":"WebSite","@id":"https:\/\/www.cnspd.com\/#website","url":"https:\/\/www.cnspd.com\/","name":"Penjaga Lonjakan, Penangkap Lonjakan, Saklar Isolasi - LEEYEE","description":"Penjaga Lonjakan, Penangkap Lonjakan, Saklar Isolasi - LEEYEE","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cnspd.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Person","@id":"https:\/\/www.cnspd.com\/#\/schema\/person\/f49dbafe62c5b47100ad2d9f88af92d3","name":"Devin Ling","sameAs":["https:\/\/cnspd.com\/"],"url":"https:\/\/www.cnspd.com\/id\/author\/devin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/posts\/31631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/comments?post=31631"}],"version-history":[{"count":4,"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/posts\/31631\/revisions"}],"predecessor-version":[{"id":31635,"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/posts\/31631\/revisions\/31635"}],"wp:attachment":[{"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/media?parent=31631"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/categories?post=31631"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cnspd.com\/id\/wp-json\/wp\/v2\/tags?post=31631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}