Artikel Nr.: LYB-12.5/275 3(S)+1

Key Specifications:

Modell
LY1-B25/3(S)+1

Typ
Class I+II / Type 1+2 AC SPD

Pole
3P+N Monoblock Design

Network System
TT / TN-S

Schutzmodus
L-N / N-PE

Iimp
25kA / 100kA, 10/350μs

In / Imax
25kA / 100kA In, 100kA Imax

Montage
35mm DIN Rail

Jetzt zitieren

    High-Energy Type 1+2 AC Surge Protection for 3P+N Systems

    LY1-B25/3(S)+1 is a monoblock 3P+N Type 1+2 AC surge protective device designed for TT and TN-S low-voltage distribution systems. It combines high-energy MOV and GDT protection elements to protect three-phase plus neutral incoming power circuits from lightning surges and transient overvoltage.


    Class I+II / Type 1+2 AC SPD for main distribution board protection

    3P+N protection design for TT and TN-S network systems

    High-energy MOV and GDT elements for L-N and N-PE protection

    100kA total discharge current for high-energy surge protection

    Suitable Applications

    LY1-B25/3(S)+1 is suitable for TT and TN-S three-phase plus neutral AC systems where Type 1+2 surge protection is required at the incoming power side or main distribution level.

    Main Distribution Boards

    For incoming surge protection in 3P+N AC distribution boards and low-voltage panels.

    🏢

    Kommerzielle Gebäude

    Helps protect commercial building power systems with three-phase plus neutral distribution.

    Industrial Power Panels

    Suitable for industrial low-voltage panels requiring high-energy Type 1+2 surge protection.

    Solar AC Side Panels

    Can be used on the AC side of solar systems when voltage, network system, and protection mode match the design.

    FAQ

    Common questions about LY1-B25/3(S)+1 3P+N monoblock AC surge protective device selection and application.

    What is LY1-B25/3(S)+1 used for?

    LY1-B25/3(S)+1 is used for Type 1+2 AC surge protection in TT and TN-S three-phase plus neutral systems. It protects L-N and N-PE paths at the main distribution board or incoming power side.

    What does 3P+N mean?

    3P+N means the SPD is designed for three-phase plus neutral systems, with protection paths between L-N and N-PE depending on the system design.

    What surge ratings does this SPD provide?

    The product provides 25kA / 100kA impulse discharge current Iimp, 25kA / 100kA nominal discharge current In, 100kA maximum discharge current Imax, and 100kA total discharge current Itotal.

    What is the role of MOV and GDT in this SPD?

    The MOV helps clamp transient overvoltage quickly, while the GDT is used for high-energy discharge, especially in the N-PE protection path.

    Does this model support remote signalling?

    Yes. The “S” version can include optional remote contact for SPD status monitoring. Please confirm this requirement before ordering.

    What should be confirmed before ordering?

    Please confirm system voltage, TT or TN-S network system, L-N / N-PE protection mode, backup fuse, installation space, wiring cross-section, and remote signalling requirement before ordering.

    Technische Daten

    Detailed electrical, mechanical, and installation data for LY1-B25/3(S)+1 3P+N monoblock AC surge protective device selection.

    Parameter150V275V320V385V
    Nominal AC Voltage Uo / Un120V230V230V230V
    Maximum Continuous Operating Voltage Uc (L-N)150V275V320V385V
    Maximum Continuous Operating Voltage Uc (N-PE)255V
    Nominal Discharge Current In, 8/20μs (L-N / N-PE)25kA / 100kA
    Maximum Discharge Current Imax, 8/20μs100kA
    Impulse Discharge Current Iimp, 10/350μs (L-N / N-PE)25kA / 100kA
    Total Discharge Current Itotal, 10/350μs100kA
    Specific Energy W/R (L-N / N-PE)156 kJ / Ω / 2.5 MJ / Ω
    Charge Q (L-N / N-PE)12,5 As / 50 As
    Voltage Protection Level Up (L-N / N-PE)1.0kV / 1.5kV1.5kV / 1.5kV1.6kV / 1.5kV1.8kV / 1.5kV
    Follow Current Interrupt Rating Ifi (N-PE)100 ARMEN
    Response Time tA (L-N / N-PE)< 25 ns / < 100 ns
    Back-Up Fuse Max.315A gL / gG
    Short-Circuit Current Rating ISCCR (L-N)50kA
    TOV Withstand 5s UT (L-N)180V335V335V335V
    TOV 120min UT (L-N)230V440V440V440V
    TOV Withstand 200ms UT (N-PE)1200V
    Betriebstemperatur-40°C to +70°C
    Conductor Cross Section35mm² solid / stranded, 25mm² flexible
    Klemmenschrauben-Drehmoment4.5 Nm
    Montage35mm DIN Rail, EN 60715
    Grad des SchutzesIP20, built-in
    Material des GehäusesThermoplastic, UL 94 V-0
    Betriebszustand/StörungsanzeigeGreen: OK / Red: Defect
    Remote ContactOptional
    Selection Note:
    Please confirm system voltage, TT or TN-S network system, L-N / N-PE protection mode, backup fuse, installation space, wiring cross-section, and remote signalling requirement before ordering.

    ■ Interne Konfiguration


    ■ Abmessungen und Verpackung


    ■ Anschlussschema

    Jetzt mit der Anpassung beginnen

    Wir bieten ein umfassendes Angebot an maßgeschneiderten Dienstleistungen und arbeiten bei jedem Schritt eng mit unseren Kunden zusammen, vom Konzept bis zur Auslieferung.

    Andere&Produkte

    Unser Team orientiert sich stets an den Bedürfnissen unserer Kunden und bietet professionelle Beratung und Unterstützung, um Ihre Zufriedenheit zu gewährleisten.

    ALLES, WAS SIE NICHT FINDEN KONNTEN?

    Sprechen Sie mit unserem Vertrieb

    Da wir wissen, dass jedes Unternehmen einzigartig ist, bieten wir maßgeschneiderte Dienstleistungen an, um sicherzustellen, dass unsere Produkte perfekt auf Ihre spezifischen Bedürfnisse zugeschnitten sind:

    • Umfassende Broschüre zum Herunterladen
    • 15 Jahre Erfahrung in der Fabrik
    • Schnelle Lieferung
    • OEM&ODM
    • Niedriger Preis
    • Kleiner MQQ

    SENDEN SIE UNS EINE E-MAIL

    devin@cnspd.com

    Kontakt

    Wir bewerten und verbessern unsere Prozesse ständig, um sicherzustellen, dass wir die effizientesten und zuverlässigsten Elektroprodukte auf dem Markt liefern.