Artikel Nr.: LYM5-63

Key Specifications:

LYM5-63 Miniature Circuit Breaker is designed for overload and short-circuit protection in low-voltage AC distribution systems. It is suitable for residential, commercial, industrial control panels, distribution boards, and OEM electrical assemblies.

Nennstrom
6A–63A

Schaltleistung
6kA

Pole
1P / 2P / 3P / 4P

Montage
35mm DIN Rail

Jetzt zitieren

    AC-Leitungsschutzschalter

    LYM5-63 Miniature Circuit Breaker for Reliable AC Circuit Protection

    LYM5-63 MCB is used to protect low-voltage electrical circuits against overload and short-circuit faults. With 6kA breaking capacity, B/C/D trip curves, 1P to 4P configurations, and 35mm DIN rail mounting, it is suitable for distribution boards, control panels, residential systems, commercial buildings, and OEM electrical assemblies.

    Key Specifications

    Modell
    LYM5-63

    Produkttyp
    Miniatur-Leitungsschutzschalter

    Nennstrom
    6A–63A

    Nennspannung
    230 / 400V AC

    Schaltleistung
    6kA

    Reisekurve
    B / C / D

    Pole
    1P / 2P / 3P / 4P

    Einrichtung
    35mm DIN Rail

    Why Choose LYM5-63 MCB?

    Überlastungsschutz

    Helps prevent cable and equipment damage caused by long-term overload current in AC distribution circuits.

    Short-Circuit Protection

    Quickly disconnects the circuit during short-circuit faults to improve system safety and reduce electrical risk.

    Flexible Selection

    Available in multiple current ratings, pole configurations, and B/C/D trip curves for different load types.

    OEM Supply Support

    Suitable for electrical wholesalers, panel builders, OEM brands, contractors, and distribution board manufacturers.

    Typische Anwendungen

    Distribution Boards

    For branch circuit protection in residential and commercial distribution boxes.

    Control Panels

    For low-voltage panel protection in machine control and light industrial systems.

    Kommerzielle Gebäude

    For lighting circuits, socket circuits, and small power distribution systems.

    OEM Electrical Assemblies

    For manufacturers that need stable supply, private labeling, and batch production.

    How to Select the Right LYM5-63 MCB

    Selection Item
    Empfehlung
    Aktuelle Bewertung
    Select according to cable size, load current, and local electrical design requirements.
    Pole Configuration
    Use 1P for single-line protection, 2P for single-phase L+N, and 3P/4P for three-phase systems.
    Reisekurve
    B curve for sensitive loads, C curve for general distribution, and D curve for higher inrush-current loads.
    Schaltleistung
    Confirm that the short-circuit capacity of the installation point does not exceed the MCB rating.

    Note: Final model selection should be confirmed according to the electrical system design, installation environment, cable size, load type, and local standards.

    Built to Protect. Trusted to Last.

    LEEYEE supplies miniature circuit breakers and related low-voltage protection products for electrical distributors, panel builders, contractors, and OEM customers. We support stable batch supply, product matching, private label options, and export orders.

    FAQ

    What is the LYM5-63 MCB used for?

    It is used for overload and short-circuit protection in low-voltage AC circuits, such as distribution boards, control panels, and commercial electrical systems.

    What current ratings are available?

    Common ratings include 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A.

    What is the difference between B, C, and D curve?

    B curve is usually used for sensitive or low-inrush loads, C curve is common for general distribution, and D curve is used for loads with higher starting current.

    Can LEEYEE support OEM or private label orders?

    Yes. LEEYEE supports OEM supply for electrical distributors, panel builders, and brands that need stable batch production and export packaging.

    Is this product suitable for solar DC circuits?

    This LYM5-63 model is positioned as an AC miniature circuit breaker. For solar PV DC systems, please select a dedicated DC MCB according to system voltage and polarity requirements.

    Technische Daten

    Nennstrom: 6A,10A,16A,20A,25A,32A,40A,50A,63A
    Rated Voltage:230/400VAC(240/415)
    Nennfrequenz: 50/60Hz
    Anzahl der Pole: 1P,2P,3P,4P(1P+N,3P+N)
    Modulgröße:18mm
    IC-Kurve Typ: B,C,D Typ
    Ausschaltvermögen: 6000A
    Optimale Betriebstemperatur: -5°C bis 40°C
    Klemme Anzugsdrehmoment: 5N-m
    Anschlusskapazität (oben): 25mm?
    Anschlusskapazität (unten): 25 mm?
    Elektromechanische Ausdauer:4000Zyklen
    Montage: 35mm DinRail
    Geeignete Stromschiene: PIN-Sammelschiene

    Einhaltung der Vorschriften

    IEC60898-1
    EN60898-1

    Gesamt- und Einbaumaße

    Die Auslösecharakteristikkurven

    Jetzt mit der Anpassung beginnen

    Wir bieten ein umfassendes Angebot an maßgeschneiderten Dienstleistungen und arbeiten bei jedem Schritt eng mit unseren Kunden zusammen, vom Konzept bis zur Auslieferung.

    Andere&Produkte

    Unser Team orientiert sich stets an den Bedürfnissen unserer Kunden und bietet professionelle Beratung und Unterstützung, um Ihre Zufriedenheit zu gewährleisten.

    ALLES, WAS SIE NICHT FINDEN KONNTEN?

    Sprechen Sie mit unserem Vertrieb

    Da wir wissen, dass jedes Unternehmen einzigartig ist, bieten wir maßgeschneiderte Dienstleistungen an, um sicherzustellen, dass unsere Produkte perfekt auf Ihre spezifischen Bedürfnisse zugeschnitten sind:

    • Umfassende Broschüre zum Herunterladen
    • 15 Jahre Erfahrung in der Fabrik
    • Schnelle Lieferung
    • OEM&ODM
    • Niedriger Preis
    • Kleiner MQQ

    SENDEN SIE UNS EINE E-MAIL

    devin@cnspd.com

    Kontakt

    Wir bewerten und verbessern unsere Prozesse ständig, um sicherzustellen, dass wir die effizientesten und zuverlässigsten Elektroprodukte auf dem Markt liefern.