Artikel Nr.: LY26-XF Signal SPD

Wichtige Spezifikationen:

Modell
LY26-XF

Produkttyp
Waterproof Explosion-Proof Signal SPD

Rated Voltage Options
5V / 12V / 24V / 48V / 110V / 220V

Maximale Dauerspannung
6V / 15V / 30V / 50V / 230V / 420V

Nenn-Entladestrom
In 5kA, 8/20μs

Reaktionszeit
≤ 1ns

Einfügedämpfung
≤ 0.3dB

Protection Circuits
Single-Channel or Dual-Channel

Jetzt zitieren

    Waterproof Surge Protection for Outdoor and Hazardous Signal Lines

    LY26-XF is a waterproof and explosion-proof signal surge protective device designed for RS485 data transmission, industrial communication, and field-control lines. Its multistage semiconductor protection provides fast transient suppression, low residual voltage, and low insertion loss for sensitive equipment installed outdoors or in demanding industrial environments.


    Waterproof enclosure for outdoor signal-line installations

    Suitable for RS485, communication, and control signal lines

    Fast response time of no more than 1ns

    Single-channel and dual-channel protection options

    Geeignete Anwendungen

    LY26-XF is designed for outdoor and industrial signal circuits that require reliable surge protection, moisture resistance, and a robust enclosed construction.

    RS485 Control Lines

    Protects RS485 data transmission and industrial control circuits exposed to induced surges.

    🏭

    Chemical Plants

    Suitable for field-control and data lines in chemical workshops and other demanding industrial locations.

    Fuel & Gas Facilities

    For signal lines in gas stations, oil depots, gas storage areas, and fuel-handling facilities.

    📹

    Outdoor Security Systems

    Helps protect outdoor monitoring, alarm, access-control, firefighting, and security signal circuits.

    FAQ

    Common questions about LY26-XF waterproof and explosion-proof signal-line surge protection.

    Wofür wird der LY26-XF verwendet?

    LY26-XF wurde entwickelt, um RS485, Datenkommunikation und Steuerleitungssignale gegen blitzbedingte und schaltbedingte Überspannungen zu schützen.

    Ist der LY26-XF für die Installation im Freien geeignet?

    Ja. Es verwendet ein wasserdichtes Gehäuse und ist für Anwendungen im Freien mit Signalleitungen gedacht, bei denen Feuchtigkeit und Umwelteinflüsse berücksichtigt werden müssen.

    Welche Spannungsvariante sollte ausgewählt werden?

    Wählen Sie die 5V-, 12V-, 24V-, 48V-, 110V- oder 220V-Version entsprechend der normalen Betriebsspannung des geschützten Signalstromkreises und der entsprechenden maximalen Dauerspannung aus.

    Unterstützt LY26-XF den Einzelkanal- und den Dualkanalschutz?

    Ja. Das Produkt ist mit einem Einzelkanalschutz für die Terminals 1 und 2 oder einem Zweikanalschutz für die Terminals 1, 2, 3 und 4 erhältlich.

    Wird der Schützer das Signal erheblich beeinflussen?

    The listed insertion loss is no more than 0.3dB. Final compatibility should still be checked against the actual protocol, line impedance, transmission distance, and signal frequency.

    Was sollte vor der Bestellung bestätigt werden?

    Confirm the signal voltage, maximum continuous voltage, number of protected channels, wiring arrangement, communication protocol, installation environment, grounding method, enclosure requirements, and required certification.

    Technische Daten

    Electrical, signal-performance, enclosure, and circuit-configuration data for LY26-XF waterproof explosion-proof signal surge protector selection.

    Parameter 5V 12V 24V 48V 110V 220V
    Signal Circuit Ratings
    Modell LY26-XF
    Rated Operating Voltage Un 5V 12V 24V 48V 110V 220V
    Maximale Dauerbetriebs-spannung Uc 6V 15V 30V 50V 230V 420V
    Surge & Signal Performance
    Nennstoßstrom In, 8/20μs 5kA
    Reaktionszeit ≤ 1ns
    Einfügedämpfung ≤ 0.3dB
    Enclosure & Circuit Configuration
    Housing Waterproof and Explosion-Proof Enclosure
    Single-Channel Protection Circuit Terminals 1 and 2
    Dual-Channel Protection Circuit Terminals 1, 2, 3 and 4
    Typical Protected Lines RS485, Data Communication and Field-Control Signal Lines
    Installation Zone Signal equipment interface from LPZ 1 to LPZ 3
    Auswahlhinweis:
    Select the voltage version according to the normal operating voltage and maximum continuous voltage of the protected signal line. Confirm the single-channel or dual-channel wiring arrangement, communication protocol, signal frequency, grounding method, enclosure installation, and hazardous-area requirements before ordering.

    Certification Note:
    “Explosion-proof” requirements vary by country and application. Confirm the exact explosion-protection certificate, marking, gas group, temperature class, enclosure rating, and installation method before using the product in a regulated hazardous area.

    Jetzt mit der Anpassung beginnen

    Wir bieten ein umfassendes Angebot an maßgeschneiderten Dienstleistungen und arbeiten bei jedem Schritt eng mit unseren Kunden zusammen, vom Konzept bis zur Auslieferung.

    Andere&Produkte

    Unser Team orientiert sich stets an den Bedürfnissen unserer Kunden und bietet professionelle Beratung und Unterstützung, um Ihre Zufriedenheit zu gewährleisten.

    ALLES, WAS SIE NICHT FINDEN KONNTEN?

    Sprechen Sie mit unserem Vertrieb

    Da wir wissen, dass jedes Unternehmen einzigartig ist, bieten wir maßgeschneiderte Dienstleistungen an, um sicherzustellen, dass unsere Produkte perfekt auf Ihre spezifischen Bedürfnisse zugeschnitten sind:

    • Umfassende Broschüre zum Herunterladen
    • 15 Jahre Erfahrung in der Fabrik
    • Schnelle Lieferung
    • OEM&ODM
    • Niedriger Preis
    • Kleiner MQQ

    SENDEN SIE UNS EINE E-MAIL

    devin@cnspd.com

    Kontakt

    Wir bewerten und verbessern unsere Prozesse ständig, um sicherzustellen, dass wir die effizientesten und zuverlässigsten Elektroprodukte auf dem Markt liefern.