Type 1+2 DIN Rail SPD · For Main Panels and Higher Surge Risk

Type 1+2 DIN Rail Surge Protector for Main Panels

LEEYEE supplies Type 1+2 DIN rail surge protectors for incoming panels, main distribution boards, industrial electrical cabinets and installations with higher lightning or surge exposure. This page helps buyers choose a combined Type 1 and Type 2 SPD by installation point, system voltage, impulse current requirement and panel design.

Compare DIN Rail SPD Types
Product Identity
Type de produit Type 1+2 DIN Rail SPD
Montage Rail DIN 35 mm
Application Main Panel / Incoming Side
Protection Role Combined Type 1 and Type 2
Common Options AC / DC Project Options
Supplier LEEYEE
Combined Protection Combines Type 1 lightning current and Type 2 surge protection functions.
Main Panel Use For incoming panels, main boards and higher exposure installations.
DIN Rail Mounting Designed for modular panel and cabinet integration.
Support OEM For panel builders, brands, distributors and project buyers.

What is a Type 1+2 DIN rail surge protector?

A Type 1+2 DIN rail surge protector is a combined surge protective device designed to provide both lightning current discharge capability and distribution-level surge protection in one modular device. It is commonly used at the incoming side of a low-voltage system, especially where the installation has higher surge exposure or project requirements call for combined protection.

Type 1+2 is not just a larger Type 2 SPD. It is selected when both impulse current capability and downstream surge limitation are needed at the panel level.
DIN rail describes how it is mounted. The device clips onto a standard 35 mm DIN rail inside a main panel, distribution board or electrical cabinet.
Selection depends on the incoming system. Voltage, wiring system, Iimp, In, Imax, Up, earthing system and backup protection should be checked before ordering.
Quand utiliser

When should you choose a Type 1+2 DIN rail SPD?

Type 1+2 DIN rail SPDs are usually selected for incoming panels or projects where a standard Type 2 SPD may not be enough. The decision should be based on system exposure, installation position and project requirements.

Project ConditionRecommended ChoiceWhy It MattersBuyer Note
Main incoming panelType 1+2 DIN rail SPDThe incoming side may face higher surge energy before internal distribution.Confirm system voltage, wiring and earthing before selection.
External lightning protection system nearbyType 1 or Type 1+2 SPD may be requiredSystems with higher lightning exposure need impulse current capability.Follow project design and local electrical requirements.
Overhead line or exposed installationType 1+2 may be safer than only Type 2Overhead supply routes can increase surge exposure.Check risk level and coordination with downstream protection.
Industrial or critical equipment panelType 1+2 at incoming side, Type 2 downstream if neededCritical systems may need layered surge protection.Consider downstream equipment sensitivity and panel layout.
Standard sub-distribution boardType 2 DIN rail SPD may be enoughNot every panel needs Type 1+2 protection.Use Type 2 page for ordinary distribution-level protection.
Applications

Where Type 1+2 DIN rail surge protectors are used

Type 1+2 SPDs are most useful where the buyer needs a compact DIN rail device for incoming protection and higher surge exposure conditions.

Main Distribution

Incoming panels and main boards

Used near the incoming side of low-voltage electrical systems where combined protection is required.

Industrial Panels

Factory and control cabinets

Suitable for industrial panels, machinery cabinets and electrical systems with higher exposure or critical loads.

Project Supply

OEM and panel builder projects

Useful for OEM cabinet builders and project buyers who need consistent DIN rail SPD supply and model matching.

Selection Guide

How to choose a Type 1+2 DIN rail SPD

A Type 1+2 SPD should be selected by the actual system design. Do not choose only by the highest kA value. Check the full datasheet and match the SPD to voltage, wiring, discharge current and installation position.

AC Type 1+2 DIN Rail SPD

For main AC distribution panels, incoming boards and industrial electrical cabinets.

Classe SPD Type 1+2
System Low-Voltage AC
Montage Rail DIN 35 mm
Application Main Panel / Incoming Side
Buyer Type Distributors / Panel Builders
Compare Type 2 SPD

OEM Type 1+2 DIN Rail SPD

For brands, panel builders and project buyers who need repeated supply and product matching.

Supply Type Factory Direct / OEM
Support Label / Packaging / Selection
Use Case Main Cabinets / Project Panels
Sample Available on Request
Quote Based on Model and Quantity
Back to DIN Rail SPD Guide
Why LEEYEE

Built for B2B surge protection supply

LEEYEE is a specialized surge protection and low-voltage protection supplier, trusted for solar PV, power distribution, telecom, industrial, and OEM applications.

Type 1+2 SPD Supply Support for main panels, incoming boards and higher exposure installations.
DIN Rail Integration Suitable for modular distribution boards and electrical cabinet layouts.
OEM Cooperation Private label, packaging and project-based supply communication.
Selection Support Help buyers match voltage, wiring, Iimp requirement and installation position.

CNSPD is LEEYEE’s surge protection-focused brand platform, built to help global buyers source reliable SPDs and related low-voltage protection products.

Installation Notes

Installation details to confirm before ordering

Type 1+2 DIN rail SPDs should be selected and installed according to the actual project design, incoming system condition, earthing method, backup protection and manufacturer datasheet.

Check before selection

  • Incoming system voltage and maximum continuous operating voltage.
  • Single-phase or three-phase wiring.
  • Earthing system and pole configuration.
  • Required Iimp, In, Imax and Up values.
  • Main panel location and exposure level.
  • Backup fuse or circuit breaker requirements.

Avoid these mistakes

  • Choosing Type 1+2 only because it looks stronger.
  • Ignoring whether the panel really needs impulse current capability.
  • Using Type 2 where project design requires Type 1+2.
  • Installing with long and messy connection leads.
  • Skipping backup protection coordination.
  • Replacing models without checking datasheets and coordination.
Related Pages

Continue your SPD selection

Choose the related page that better matches your system type, installation position or voltage requirement.

General Guide

DIN Rail Surge Protector

Start here if you need to compare AC, DC, Type 2 and Type 1+2 DIN rail surge protectors.

AC Panels

Type 2 DIN Rail Surge Protector

For AC distribution boards, sub-panels, control cabinets and standard panel-level protection.

Solar PV

DC DIN Rail Surge Protector

For PV combiner boxes, inverter DC inputs and solar DC surge protection applications.

FAQ

Type 1+2 DIN rail surge protector FAQs

What is a Type 1+2 DIN rail surge protector used for?

It is used for combined lightning current and surge protection, commonly near incoming panels, main distribution boards and installations with higher surge exposure.

Is Type 1+2 SPD better than Type 2 SPD?

Not always. Type 1+2 is used when the installation needs impulse current capability and distribution-level surge protection. For ordinary sub-distribution panels, Type 2 may be enough.

Where should a Type 1+2 SPD be installed?

It is commonly installed near the incoming side of a low-voltage electrical system, such as a main distribution board or main electrical cabinet.

What information should I send before requesting a quote?

Please send system voltage, AC or DC type, wiring system, installation location, expected SPD class, required standard, quantity and target market.

Does LEEYEE support OEM Type 1+2 DIN rail SPDs?

Yes. LEEYEE supports OEM and distributor projects for Type 1+2 DIN rail surge protectors, including model selection, labeling, packaging and B2B supply communication.

Need a Type 1+2 DIN rail SPD for your main panel?

Send us your system voltage, wiring type, installation position and project requirement. LEEYEE will help you match the suitable Type 1+2 DIN rail surge protector for your incoming panel, main distribution board or OEM cabinet.