Articolo n: LY1-C40PV 2P 800V T2

Specifiche Chiave:

Modello
LY1-C40PV 2P 800V T2

Tipo SPD
Classe II / Tipo 2 SPD DC

Maximum PV Voltage
800V DC

Configurazione dei poli
Design pluggabile a 2 poli

Protected Conductors
DC Positive / Negative Poles

Corrente di scarica massima
Imax 40kA

Montaggio
35mm Binario DIN

Standard
IEC 61643-31

Cita ora

    Reliable Type 2 Surge Protection for 800V DC Solar PV Systems

    LY1-C40PV 2P 800V T2 is a two-pole Type 2 DC surge protective device designed for photovoltaic and high-voltage DC systems. It provides surge protection for positive and negative DC conductors and offers a maximum discharge current of 40kA in a compact DIN-rail-mounted design.


    Class II / Type 2 protection for systems up to 800V DC

    Protezione a due poli per conduttori DC positivi e negativi

    Maximum discharge current up to 40kA

    Compact 35mm DIN-rail design for PV and DC cabinets

    Applicazioni Idonee

    Suitable for photovoltaic and DC systems operating up to 800V DC that require two-pole Type 2 surge protection.

    Scatole combinatore FV

    Protects positive and negative conductors in photovoltaic string and combiner-box circuits.

    String Inverter Cabinets

    Suitable for the DC input side of compatible string and commercial solar inverters.

    DC Distribution Cabinets

    For solar DC distribution boards, switching panels, and high-voltage DC equipment cabinets.

    🔋

    Battery Energy Storage

    Suitable for compatible battery energy-storage and DC charging circuits up to 800V DC.

    FAQ

    Common questions about the LY1-C40PV 800V two-pole Type 2 DC surge protective device.

    What is the LY1-C40PV 800V DC SPD used for?

    It is designed to protect photovoltaic and DC equipment against lightning-induced and switching transient overvoltage in systems operating up to 800V DC.

    Is this a Type 2 DC SPD?

    Yes. The product is classified as Class II / Type 2 and is intended for downstream protection in photovoltaic and DC distribution systems.

    Cosa protegge la configurazione a due poli?

    The two-pole configuration is intended to provide surge protection for the positive and negative conductors of a DC circuit.

    What is the maximum discharge current?

    The listed maximum discharge current Imax is 40kA. Confirm the associated test waveform and nominal discharge current from the official datasheet before final product selection.

    Where can this SPD be installed?

    Typical installation locations include PV combiner boxes, string inverter cabinets, central inverter systems, DC distribution cabinets, battery energy-storage systems, and commercial or utility-scale solar systems.

    Cosa dovrebbe essere confermato prima di ordinare?

    Confirm the maximum PV open-circuit voltage, nominal discharge current, voltage protection level, short-circuit rating, wiring arrangement, grounding system, backup protection, conductor size, and remote-contact requirement.

    Dati tecnici

    Available electrical and installation data for the LY1-C40PV 800V two-pole Type 2 DC surge protective device.

    Parametro LY1-C40PV 2P 800V T2
    Elettrico CC
    Tipo di prodotto Dispositivo di protezione contro le sovratensioni CC
    Classificazione SPD Classe II / Tipo 2
    Maximum PV Operating Voltage 800V DC
    Configurazione dei poli 2P
    Protected Conductors DC Positive / Negative Poles
    Maximum Discharge Current Imax 40kA
    Nominal Discharge Current In Contact LEEYEE for datasheet
    Livello di Protezione alla Tensione Up Contact LEEYEE for datasheet
    Classificazione della Corrente di Cortocircuito ISCPV Contact LEEYEE for datasheet
    Tempo di risposta Contact LEEYEE for datasheet
    Standard IEC 61643-31
    Installation & Application
    Installazione 35mm Binario DIN
    Applicazione Solar PV / DC Systems
    Typical Installation Locations PV combiner boxes, inverter cabinets and DC distribution cabinets
    Nota di selezione:
    Confirm that the maximum PV open-circuit voltage under the lowest expected temperature does not exceed the selected SPD voltage rating.

    Datasheet Required:
    Confirm In, Up, ISCPV, response time, backup protection, conductor size, protection mode, operating temperature, status indication, and remote-contact availability before issuing a final quotation or technical submittal.

    Iniziare a personalizzare ora

    Offriamo una gamma completa di servizi personalizzati, lavorando a stretto contatto con i nostri clienti in ogni fase del processo, dalla progettazione alla consegna finale.

    Altri prodotti

    Il nostro team è sempre guidato dalle esigenze dei nostri clienti, fornendo consulenza e assistenza professionale per garantire la vostra soddisfazione.

    Nessun risultato trovato .

    TUTTO CIÒ CHE NON SEI RIUSCITO A TROVARE.

    Parlate con le nostre vendite

    Sappiamo che ogni azienda è unica, quindi offriamo servizi personalizzati per garantire che i nostri prodotti si adattino perfettamente alle vostre esigenze specifiche:

    • Una brochure completa da scaricare
    • 15 anni di esperienza in fabbrica
    • Consegna veloce
    • OEM&ODM
    • Prezzo basso
    • Piccolo MQQ

    INVIATECI UN'E-MAIL

    devin@cnspd.com

    Contatto

    Valutiamo e miglioriamo costantemente i nostri processi per garantire la fornitura dei prodotti elettrici più efficienti e affidabili del mercato.