LYAP-A6 ADJUSTABLE V/A

Short Description:

PROTECTOR

Matters needing attention

1. The equipment must be installed by qualified professionals.

2. Before operating the device, disconnect all power supplies anddo not

touch any terminal when the power supply is connected.

3. Verify that terminals are properly connected.

4. No matter whether the equipment is in normal operation, donot disassemble

or repair otherwise, producers and sellersNo responsibility isaccepted.

5. Do not use the equipment in places that may be corroded bygas,strong sunlight and rain.

6. Clean equipment with a dry cloth.

7. Failure to comply with these instructions will result in seriousinjury or seriousaccident.


Product Detail

Product Tags

Product characteristics

Microcontroller-based

Digital display of operating voltage and current values

Prevent the electrical set voltage is too high/too low current,three-phase

asymmetry and phase sequence error

Voltage measurement accuracy 2%

Key setting parameter

LED indicates overvoltage/undervoltage and overcurrent faults

6 modules, DIN rail mounting

Technical data

Rated supply voltage AC230V
Operating voltage range AC120V-300V
Rated frequency 50/60Hz
lag Overvoltage and asymmetry:5VUndervoltage:5V
Asymmetric delay 10s
Voltage measurement accuracy ≤ 2 % ( On the whole spectrum)
Rated insulation voltage 450V
Output contact 3NO
Electrical life 10⁵
Mechanical life 10⁵
Protection class IP20
Pollution degree 3
altitude <2000m
Operating temperature -5℃-40℃
humidity ≤50%or40°C (Condensation free)
Storage temperature -25℃-55℃

Electrical symbol

Product status statement

. If a voltage fault is detected during the relay’s reset/start delay count, the output relay turns on and the fault indicating LED lights up

.The operating voltage and current values will be displayed on the screen when the relay is operating normally. If a voltage or current fault is detected, the output relay tums on and the fault indication LED lights up

.Voltage failure: If the input voltage is detected to trip back to Hys after a voltage failure, During counting the relay will automatically reset reset/start delay fault indicator light off working voltage and current value flashing screen

. Current failure: When the relay fails due tocurrent trip, it will reset automatically. Reset/start delay during counting, failure indicator LED off operating voltage and current value flashing on the screen.

. Wiring diagram (Wiring is for reference only, subject to the actual)

Productinstallation and dimensions