Fabricante de comutadores de transferência automática para projetos OEM e de distribuição

B2B Automatic Transfer Switch Sourcing & OEM Guide

If you are looking for an automatic transfer switch manufacturer, ATS factory or long-term ATS supplier, the first question is not simply who can quote a transfer switch. The real procurement question is whether the supplier can match your electrical system, document the exact configuration, approve a sample and keep the approved specification consistent in bulk and repeat orders.

LEEYEE currently publishes the compact ATS-63 automatic transfer switch range for OEM buyers, distributors, panel builders and backup-power projects. The published range covers 6A–63A, 2P and 4P configurations, AC110V / AC220V / AC400V, 50/60Hz, PC class and DIN-rail mounting.[1]

Quick Answer: Is LEEYEE the Right ATS Supplier for Your Project?

LEEYEE is currently a practical sourcing option when you need a compact 6A–63A, 2P or 4P, PC-class DIN-rail ATS and want to confirm the product for OEM, distribution or panel integration. Start with the electrical configuration, then verify the exact model, dimensions, wiring, documents and sample before approving bulk production.

6A–63A Published rated-current range
2P \/ 4P Published pole configurations
PC Class Published ATS-63 class
110 / 220 / 400V AC Published voltage options
<50 ms Published transfer switching time
Barramento DIN Compact panel installation
Current scope boundary: LEEYEE’s published ATS-63 information does not establish a 3P version, CB-class version, rating above 63A, closed-transition ATS or UL 1008 certification. If your project requires any of these, request written model availability and model-specific documentation before approval.
LEEYEE compact automatic transfer switch range with 2P and 4P configurations
ATS-63 range illustration based on LEEYEE’s published product data. Use the actual quotation, product label, datasheet and approved sample as the final order reference.[1]

Already sourcing an ATS? Send the system voltage, load current, phase arrangement, normal source, backup source, quantity and OEM requirements. LEEYEE can first confirm whether ATS-63 falls inside the required project scope.

Current LEEYEE Automatic Transfer Switch Supply Scope

A manufacturer page should make the available product range easy to verify. The table below is based on the currently published ATS-63 product data rather than on a broader unverified catalogue claim.[1]

Especificação Published ATS-63 data Significado do comprador
Corrente nominal de funcionamento 6 / 10 / 16 / 20 / 25 / 32 / 40 / 50 / 63A Select by actual load and protection design, not only by a familiar catalogue rating
Rated working voltage AC110V \/ AC220V \/ AC400V Confirm the actual system voltage for both sources
Frequência 50/60Hz Both source conditions should match the intended ATS configuration
Postes 2P \/ 4P Choose according to phase arrangement, neutral treatment and project requirements
Classe PC Do not assume ATS-63 is a CB-class transfer switch
Categoria de utilização AC-31B Check the actual connected load and duty before approval
Tempo de comutação de transferência <50 ms This is switch transfer time, not the complete generator-start restoration time[2]
Corrente de curto-circuito nominal Iq 5kA Project short-circuit protection and coordination still require engineering review
Insulation / impulse rating Ui 690V / Uimp 8kV Use the actual datasheet values in project verification
Grau de proteção IP30 Check the final enclosure and installation environment
Montagem Instalação em trilho DIN Useful for compact panel integration when dimensions and terminal access fit
Direct verification: buyers can review the current ATS-63 specifications, dimensions and wiring information on the Página do produto LEEYEE ATS-63 before requesting a quotation.

Which Requirements Fit ATS-63 — and Which Need Separate Confirmation?

For B2B sourcing, a clear limitation is more useful than an oversized product claim. Use this table as an initial qualification step, then confirm the actual project conditions.

Your requirement Current published position Próxima ação
6A–63A compact ATS Inside published ATS-63 range Confirm voltage, poles, load and installation
Single-phase system 2P option published Confirm the actual conductor and neutral switching arrangement
Three-phase + neutral system 4P option published Confirm neutral switching and earthing arrangement
DIN-rail panel DIN-rail mounting published Check dimensions, wiring space and terminal access
Utility + generator backup Application supported when parameters match Confirm generator start/control sequence separately
Utility + inverter backup Possible when the AC sources and system arrangement are compatible Confirm inverter output, voltage, frequency, neutral and transfer logic
Above 63A Outside current published ATS-63 range Request separate product availability confirmation
3P ATS Not currently published for ATS-63 Do not specify without written confirmation
CB-class ATS ATS-63 is published as PC class Use a separately confirmed solution if CB class is required
Closed transition or zero-interruption load Not established by ATS-63 data Use an engineered solution designed for that requirement
2P and 4P automatic transfer switch selection for single-phase and three-phase distribution systems
2P / 4P selection concept. This is not a universal wiring diagram. Final pole and neutral-switching requirements depend on the actual system, earthing arrangement and applicable project rules.
Nota de engenharia: rated current alone is not enough for motors, pumps or other loads with significant starting current. LEEYEE’s ATS selection guide recommends checking both running current and starting current for pump loads.[2]

What Should an Automatic Transfer Switch Manufacturer Confirm Before Quotation?

A useful ATS quotation begins with the electrical system. If a supplier quotes only from “I need a 63A ATS,” important conditions can remain unresolved until the sample or installation stage.

Tensão e frequência do sistema

State the real operating voltage and 50/60Hz requirement for both normal and backup sources.

Load current and load type

Provide normal current and identify motors, pumps, compressors or other significant inrush loads.

Phase and pole arrangement

State whether the system is single-phase or three-phase and how neutral must be treated.

Normal and backup source

Identify utility, generator, inverter or second AC source and the intended operating sequence.

Panel constraints

Provide available DIN-rail space, conductor access, enclosure conditions and relevant dimensional limits.

Target market and documents

State the destination market and the exact standard, certificate, report, manual or tender document required.

How to Audit an ATS Manufacturer or ATS Factory

Buyers comparing an ATS manufacturer in China, an automatic transfer switch factory or another long-term supplier should connect every commercial claim to something that can be checked. The goal is not to collect the most certificates or factory slogans; it is to know exactly what product will be approved and shipped.

Automatic transfer switch manufacturer verification checklist for B2B buyers
Manufacturer-verification checklist. The illustration explains what buyers should verify; it is not itself factory, test or certification evidence.
Match the quotation to an identifiable model. The quotation, datasheet, sample, product label and packing list should identify the same electrical configuration.
Verify the actual ratings. Check rated current, voltage, frequency, poles, class, utilization category and installation conditions before discussing branding.
Request dimensions and wiring information. Panel builders need enough information to confirm installation space, terminals and wiring before the enclosure design is frozen.
Verify document scope rather than certificate logos. Check the manufacturer or applicant name, product/model scope, standard edition, ratings and issuing organization where relevant.
Approve a sample or first article. Use it to confirm the physical product, electrical configuration, labeling, instructions and packaging before a customized bulk order.
Define repeat-order change control. Agree how specification, component, label, packaging or documentation changes will be communicated and re-approved.
Significado de aquisição: “manufacturer” should be verifiable through the product being supplied, its technical documentation, the approved sample and the controls applied to repeat orders—not through marketing language alone.

What Can Buyers Verify About LEEYEE ATS Supply Online?

Before sending an RFQ, buyers can already verify several parts of the current LEEYEE ATS offer through the website. This reduces the gap between a manufacturer claim and a model-specific sourcing decision.

ATS-63 technical data

The product page publishes current, voltage, poles, frequency, class, AC-31B category, switching time, dimensions and installation conditions.[1]

Wiring information

The ATS-63 product page includes a wiring-diagram section so the project can be checked beyond a product photo.[1]

Independent selection content

LEEYEE maintains a separate ATS selection guide covering source transfer, 2P/4P, current, voltage and backup-source considerations.[2]

Low-voltage product context

ATS is positioned inside LEEYEE’s wider Switching & Isolation and low-voltage product structure rather than as an isolated informational topic.

For project approval: website information is a starting point. Ask for the current model-specific datasheet, wiring information, required compliance documents and sample before treating any configuration as approved for a project.

ATS Standards and Documentation Buyers Should Verify in 2026

IEC 60947-6-1:2026 is the current fourth edition of the IEC standard for transfer switching equipment. IEC states that the document applies to transfer switching equipment used to transfer a load between power sources and includes automatic transfer switching equipment, stand-alone ATS controllers, bypass/isolation TSE and ATSE with closed-transition capability. The fourth edition was published on 2 April 2026 and replaces the 2021 third edition.[3]

This does não mean that every automatic transfer switch referring to IEC 60947-6-1 is certified to the 2026 edition. For an IEC-oriented project, verify the actual model-specific certificate, test report or manufacturer documentation and check the edition, model scope and electrical ratings.

For North American projects, UL Solutions identifies UL 1008 for automatic transfer switches used in emergency systems and optional standby systems.[4] If UL 1008 is mandatory, request explicit model-specific UL evidence. A CE document, IEC reference or generic supplier statement should not be treated as equivalent evidence.

Document rule: never approve an ATS only because a supplier shows a certification logo. The relevant document must match the product and project scope being ordered.

OEM Automatic Transfer Switch Supply: From Requirement to Approved Sample

For an OEM automatic transfer switch order, electrical configuration comes before logo and packaging. LEEYEE’s ATS-63 product page states that customized services are available, but the exact customization scope for a specific order should be confirmed in the quotation and approved sample.[1]

OEM automatic transfer switch sample approval and bulk order process
Recommended OEM control path: requirement → model confirmation → sample → artwork → approval → bulk order → repeat-order control. The process illustration does not claim a fixed MOQ or production lead time.

1. Confirm the electrical configuration

Record the approved current, voltage, frequency, pole configuration, class, wiring arrangement and installation conditions. If any required parameter falls outside the published ATS-63 range, resolve it before artwork or packaging work begins.

2. Approve the model and product identity

Confirm the model number, rating information, buyer SKU and any private-label naming. Technical information printed on an OEM label must remain consistent with the approved product specification.

3. Approve label, manual and packaging requirements

Logo, product label, nameplate, instruction material, individual box, outer carton and SKU/barcode requirements can be included in the OEM discussion. Exact availability should be confirmed item by item rather than assumed.

OEM automatic transfer switch label nameplate manual and packaging customization
OEM customization illustration. Final label, nameplate, manual and packaging options must be confirmed for the actual ATS order.

4. Freeze the approved sample

The accepted sample should become a practical reference for bulk production. Keep its model, label, packaging artwork and relevant document version linked to the purchase order or approval record.

Sample Approval Checklist Before Bulk Ordering

A sample should answer more than “Does the product turn on?” For OEM and distribution programs, use it to confirm the points that later need to stay consistent.

Verificar O que verificar Useful approval record
Identidade do produto Model, current, voltage, poles and product label Approved photo + specification
Compatibilidade mecânica Dimensions, DIN-rail fit and terminal access Drawing + panel check
Transfer operation Normal/backup source switching under the agreed test conditions Agreed functional check
Wiring information Terminal identification and the intended project wiring arrangement Approved wiring document
OEM presentation Logo, nameplate, SKU/barcode, manual and packaging Approved artwork files
Compliance package Required document and exact applicable model scope Verified document set

Regra prática: do not release a customized bulk order from a quotation and product photo alone. Freeze a defined sample/specification package first.

How Should Batch and Repeat-Order Consistency Be Controlled?

Long-term distribution depends on repeatability. Before the first bulk order, agree which product characteristics must remain fixed and how a change will be handled. The exact LEEYEE inspection method for a specific ATS order should be confirmed in the commercial and quality documents rather than assumed from this page.

Model consistency

The shipped model, current rating and pole configuration should match the approved order specification.

Electrical specification

Relevant ratings and functional requirements should remain aligned with the approved model.

Label consistency

Private-label artwork, ratings, model designation and SKU information should match approved files.

Packaging consistency

Confirm manuals, individual packaging, accessories and outer-carton requirements for repeat orders.

Document version

Track the datasheet, wiring information and compliance documents used for the approved order.

Change notification

Define which electrical, mechanical, labeling or documentation changes require buyer re-approval.

Where Is a Compact 6A–63A Automatic Transfer Switch a Good Fit?

LEEYEE positions ATS-63 for compact backup-power applications such as generator backup, control panels, small distribution systems and light commercial systems.[1] Selection still depends on the actual electrical parameters and load requirements.

Generator backup

ATS-63 can be used between utility power and generator backup when the voltage, current, poles, wiring and control arrangement are compatible.[1] The published <50 ms value is the transfer switching time of the ATS; generator starting and stabilization time is separate.[2]

Quadros de distribuição compactos

DIN-rail mounting and 2P/4P options can suit compact distribution assemblies where the electrical configuration and panel layout match the ATS-63 data. Check enclosure conditions, dimensions and protective coordination before finalizing the panel.

Armários de controlo

The compact format can support backup switching for suitable cabinet circuits. Motor, pump or other high-inrush loads require additional load review rather than selection by nominal current alone.

Compatible inverter or solar backup systems

LEEYEE’s ATS selection guide includes inverter and solar backup applications.[2] Confirm inverter AC output, voltage, frequency, neutral/earthing arrangement and transfer behavior before approving the ATS.

Where LEEYEE fits best today: buyers sourcing a compact 6A–63A, 2P/4P, PC-class DIN-rail automatic transfer switch with model confirmation, OEM discussion and repeat-order requirements.

Where separate engineering or product confirmation is needed: higher-current ATS, 3P, CB-class, closed-transition, zero-interruption, hospital/data-center critical-transfer or market-specific certification requirements not established by the current ATS-63 documentation.

How MOQ, Bulk Pricing and Lead Time Should Be Confirmed

There is no responsible single MOQ, price or lead-time number that applies to every ATS order. Commercial terms can change with model, quantity, packaging, OEM artwork, documentation, sampling and destination market.

For a comparable quotation, request pricing against a defined configuration. A standard 2P ATS order and a private-label 4P order with customized packaging are different supply requirements.

Significado do comprador: compare suppliers using the same model specification, packaging basis, required documents, sample conditions, lead-time basis and repeat-order requirement—not only the lowest unit price.

ATS RFQ Checklist: What Should You Send to the Manufacturer?

A complete RFQ helps an automatic transfer switch supplier confirm the configuration faster and reduces the risk of approving the wrong sample.

Automatic transfer switch RFQ information checklist for OEM and distribution projects
ATS RFQ checklist for OEM, distributor, generator-integration and panel projects. Final model selection still requires review of the actual system.
Sistema elétrico

Voltage, frequency, rated load current, load type, single/three phase and required pole arrangement.

Power sources

Normal source, backup source, source priority and relevant generator or inverter control information.

Instalação

Panel type, available space, DIN-rail arrangement, wiring constraints and environment.

Market documents

Destination country and required standard, certificate, report, datasheet, manual or tender document.

Commercial requirement

Sample quantity, estimated bulk quantity, repeat-order plan and requested delivery schedule.

Requisito OEM

Brand, label/nameplate, SKU/barcode, manual language, individual box and outer-carton requirements.

Need an ATS model check before sampling? Send the RFQ information above. LEEYEE can compare the requirement with the current ATS-63 range and identify which points still need technical or commercial confirmation.

FAQ for OEM, Distributor and Project Buyers

What automatic transfer switch range does LEEYEE currently publish?

LEEYEE’s current ATS-63 product page lists 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A options, with AC110V / AC220V / AC400V, 50/60Hz, 2P or 4P, PC class and DIN-rail mounting.[1]

Does LEEYEE supply 2P and 4P automatic transfer switches?

Yes. The published ATS-63 range includes 2P and 4P versions.[1] The final choice depends on the actual system and neutral-switching requirements.

Does LEEYEE currently publish a 3P ATS?

Not in the ATS-63 data used for this page. The published pole options are 2P and 4P.[1] A 3P requirement should therefore be confirmed separately before specification or quotation approval.

Is LEEYEE ATS-63 PC class or CB class?

ATS-63 is published as PC class with utilization category AC-31B.[1] This page does not claim a CB-class ATS-63 configuration.

Can LEEYEE supply an ATS above 63A?

The current published ATS-63 range stops at 63A.[1] Requirements above 63A should be submitted for separate availability confirmation rather than assumed from this manufacturer page.

O ATS-63 pode ser usado para backup de gerador?

Yes, when the system voltage, current, poles, wiring and generator-side conditions match the selected ATS configuration.[1] Generator starting and stabilization time is separate from the ATS switching time.[2]

Can I use the <50 ms transfer time as the total generator backup time?

No. The published <50 ms value is the ATS transfer switching time.[1] A generator may require additional time to start and stabilize before it can support the load.[2]

Can I order an OEM or private-label automatic transfer switch?

LEEYEE’s ATS-63 product page states that customized services are available.[1] Send the required label, nameplate, manual, SKU/barcode and packaging details so the exact customization scope can be confirmed before sample approval.

Which IEC standard should an ATS buyer verify in 2026?

The current IEC edition is IEC 60947-6-1:2026, Edição 4.0, publicado a 2 de abril de 2026.[3] A reference to the standard does not by itself prove that a particular ATS is certified to that edition, so verify the actual product-document scope.

Does LEEYEE ATS-63 have UL 1008 certification?

This page does not claim UL 1008 certification for ATS-63. If UL 1008 is mandatory for your project, request model-specific evidence before approval. UL Solutions identifies UL 1008 as a relevant standard for automatic transfer switches used in emergency and optional standby systems.[4]

What information should I send for an ATS quotation?

Send the system voltage and frequency, load current and load type, phase and pole requirement, normal and backup sources, installation constraints, destination market, required documentation, quantity and OEM requirements.

Referências

  1. LEEYEE. Automatic Transfer Switch for Solar & Home Backup | LEEYEE 2P/4P ATS. Official ATS-63 product page. Published data includes 6A–63A, 2P/4P, AC110V/220V/400V, 50/60Hz, PC class, AC-31B, <50 ms transfer switching time, Iq 5kA, Ui 690V, Uimp 8kV, IP30, dimensions and DIN-rail mounting.
  2. LEEYEE. O que é um comutador automático de transferência? Como funciona o ATS e como escolher. Technical selection guide covering ATS function, 2P/4P selection, current, voltage, backup sources and the distinction between ATS switching time and generator start/recovery time.
  3. Comissão Eletrotécnica Internacional. IEC 60947-6-1:2026, Edition 4.0 — Low-voltage switchgear and controlgear – Part 6-1: Multiple function equipment – Transfer switching equipment. Publication date: 2 April 2026. IEC states that the fourth edition cancels and replaces the third edition published in 2021.
  4. UL Solutions. Serviços de certificação e avaliação de comutadores. UL Solutions lists UL 1008 for automatic transfer switches used in emergency systems and optional standby systems.
Postagem Anterior.
Guia de seleção de comutadores de transferência automática para fabricantes de quadros elétricos e compradores OEM
Próximo post.
Automatic Transfer Switch for Generator Backup Power Systems
Devin Ling - Engenheiro Eletricista na LEEYEE Electrics

Devin Ling

Engenheiro Eletrotécnico na LEEYEE Electrics

Mais de 10 anos em dispositivos de proteção contra sobretensões
Especializado em IEC 61643 / UL 1449
Experiência em sistemas solares fotovoltaicos e industriais

Falar com um engenheiro Obter recomendação técnica

Não tem a certeza de qual o SPD adequado para o seu sistema?
Obtenha uma recomendação rápida dos nossos engenheiros.

Sobre a LEEYEE:

Criada em 2009, LEEYEE é um fabricante especializado de dispositivos de proteção de baixa tensão. Nós possuímos os certificados de CE, CB, ISO9001, e TUV. Além disso, nós apoiamos opções de personalização para aparência de cor, parâmetros e logotipos. Bem-vindo a consultar para catálogos de produtos e inquéritos, pode contactar-nos através do e-mail max@cnspd.com.

Citar agora

    LEEYEE Elétrico

    Relacionadas
    &Produtos