Item No.: LY1-D20M/1(S)+1

Key Specifications:

Model
LY1-D20M/1(S)+1

Type
Class II+III / Type 2+3 AC SPD

System
1P+N Single-Phase System

Protection Mode
L-N / N-PE

Protection Elements
High-Energy MOV + GDT

Voltage Options
75V / 150V / 275V / 320V AC

In / Imax
10kA / 20kA, L-N and N-PE

Mounting
35mm DIN Rail

Quote Now

    Compact Type 2+3 AC Surge Protection for 1P+N Systems

    LY1-D20M/1(S)+1 is a compact 1P+N pluggable Type 2+3 AC surge protective device for single-phase plus neutral systems. Its coordinated MOV and GDT structure provides L-N and N-PE protection with 10kA nominal discharge current and 20kA maximum discharge current, while the mini-size housing helps save DIN-rail space.


    Class II+III / Type 2+3 downstream surge protection

    Compact 1P+N configuration with L-N and N-PE protection

    Coordinated high-energy MOV and GDT protection technology

    Pluggable modules with visual status indication and optional remote contact

    Suitable Applications

    LY1-D20M/1(S)+1 is suitable for compact single-phase plus neutral systems requiring coordinated Type 2+3 surge protection in limited DIN-rail space.

    Residential Panels

    For compact residential distribution boards and single-phase household consumer units.

    Compact Control Panels

    Suitable for small machinery controls, automation cabinets, HVAC panels, and compact equipment boxes.

    🔋

    UPS & Telecom Power

    Helps protect UPS inputs, telecom power supplies, communication equipment, and sensitive electronic loads.

    Solar Inverter AC Boxes

    For single-phase solar inverter AC-side boxes when the selected Uc rating matches the system voltage.

    FAQ

    Common questions about LY1-D20M/1(S)+1 compact 1P+N pluggable Type 2+3 AC surge protective device selection.

    What is LY1-D20M/1(S)+1 used for?

    LY1-D20M/1(S)+1 is used for downstream and final-distribution surge protection in compact single-phase plus neutral AC systems. It helps limit transient overvoltage through coordinated L-N and N-PE protection paths.

    Is LY1-D20M/1(S)+1 a multi-pole three-phase SPD?

    No. LY1-D20M/1(S)+1 is a compact 1P+N SPD for single-phase plus neutral systems. The previous description referring to a three-phase multi-pole system should not be used.

    Is this a Type 2 or Type 3 SPD?

    LY1-D20M/1(S)+1 is classified as Class II+III / Type 2+3, making it suitable for coordinated downstream and final-distribution surge protection.

    What protection technology does it use?

    It combines a high-energy MOV on the L-N path with a gas discharge tube on the N-PE path, providing coordinated protection for single-phase plus neutral systems.

    What discharge current ratings does it provide?

    It provides 10kA nominal discharge current and 20kA maximum discharge current on both the L-N and N-PE protection paths.

    What should be confirmed before ordering?

    Confirm the nominal L-N voltage, required Uc and Up level, 1P+N wiring arrangement, 125A maximum backup-fuse coordination, DIN-rail space, conductor size, and optional remote-contact requirement.

    Technical Data

    Electrical, mechanical, environmental, and installation data for LY1-D20M/1(S)+1 compact 1P+N pluggable Type 2+3 AC surge protective device selection.

    Parameter75V150V275V320V
    IEC Electrical
    Nominal AC Voltage Uo / Un60V120V230V230V
    Maximum Continuous Operating Voltage Uc, L-N75V150V275V320V
    Maximum Continuous Operating Voltage Uc, N-PE255V
    Nominal Discharge Current In, L-N / N-PE10kA / 10kA, 8/20μs
    Maximum Discharge Current Imax, L-N / N-PE20kA / 20kA, 8/20μs
    Voltage Protection Level Up, L-N / N-PE0.2kV / 1.5kV0.6kV / 1.5kV1.3kV / 1.5kV1.5kV / 1.5kV
    Follow Current Interrupt Rating Ifi, N-PE100 ARMS
    Response Time tA, L-N / N-PE<25ns / <100ns
    Back-Up Fuse Max.125A gL / gG
    Short-Circuit Current Rating ISCCR, L-N10kA
    TOV Withstand 5s UT, L-N90V180V335V335V
    TOV 120min UT, L-N115V230V440V440V
    TOV ModeWithstandSafe FailSafe FailSafe Fail
    TOV Withstand 200ms UT, N-PE1200V
    Mechanical & Environmental
    Operating Temperature Range-40°C to +70°C
    Permissible Operating Humidity5%–95%
    Atmospheric Pressure / Altitude80kPa–106kPa / -500m to 2000m
    Terminal Screw Torque39.9lbf·in / 4.5Nm
    Conductor Cross Section Max.2 AWG solid/stranded; 4 AWG flexible; 35mm² solid/stranded; 25mm² flexible
    Mounting35mm DIN Rail, EN 60715
    Degree of ProtectionIP20, built-in
    Housing MaterialThermoplastic, UL94 V-0
    Thermal ProtectionYes
    Operating State / Fault IndicationGreen: OK / Red: Defect
    Remote ContactsOptional
    RC Switching CapacityAC 250V / 0.5A; DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
    RC Conductor Cross Section Max.16 AWG solid / 1.5mm² solid
    Selection Note:
    Confirm the nominal L-N voltage, required Uc and Up level, 1P+N wiring arrangement, 125A maximum backup fuse, conductor size, DIN-rail space, and optional remote contact before ordering.

    ■ Internal Configuration


    ■ Dimensions & Packaging


    ■ Connection Diagram

    Start Customizing Now

    We offer a full range of customised services, working closely with our customers every step of the way, from concept design to final delivery.

    Other&Products

    Our team is always guided by the needs of our customers, providing professional consultation and support to ensure your satisfaction.

    No results found .

    ANYTHING YOU COULDN’T FIND?

    Talk With Our Sales

    We know that every business is unique, so we offer customized services to ensure that our products perfectly match your specific needs:

    • Comprehensive brochure you can download
    • 15 years factory experience
    • Fast delivery
    • OEM&ODM
    • Low price
    • Small MQQ

    SEND US AN EMAIL

    devin@cnspd.com

    Contact Us

    We constantly evaluate and improve our processes to ensure that we are delivering the most efficient and reliable electrical products on the market.