Item No.: LYDS6

LYDS6

Description:

LYDS6 Screw fixing doesn’t interfere with the sealing performance; Multiple mechanical seals around the shaft guarantee the reliability of a waterproof and moisture-proof design; Stainless steel rotary screw does not rust nor damp; Standard cable interface available with seal rings; Internal sealing in top and bottom covers, combined with 2 screws, guarantee an IP66 protection degree.
Quote Now

    The LYDS6 DC Isolator Switch is a durable DC manual disconnect designed for reliable isolation of battery and DC power circuits in renewable energy, backup systems, and industrial applications.

    🔹 Key Technical Knowledge

    • Product type: DC isolator switch

    • Rated current: mid-range DC amperage suitable for solar and storage

    • Contacts: DC positive break mechanism

    • Installation: Panel or enclosure mount

    • Compliance: IEC 60947-3 for DC switching performance

    • Manufacturer role: OEM-ready DC isolator factory supplier

    🔹 Use Cases / Industries

    • Residential and commercial solar PV systems

    • Battery backup systems

    • Telecom DC cabinets

    • Industrial DC feeders

    • Off-grid energy installations

    🔹 OEM & Manufacturing Advantage

    As a professional DC isolator manufacturer, we offer bulk supply, OEM branding, custom current ratings, and global logistics support.

    Technical Data

      Main Parameters
      Model  A 13 20 25 40 50
      Rated insulation voltage      Ui  V 1500 1500 1500 1500 1500
      Rated thermal curent          Ith  A 32 40 55 55 55
      Rated impuke withstand voltage Uimp  V  8000
       Rated short-time withstand current(1s)kow  A  780
      Rated short-time making capacty kcm  A  1200
    Maximum cable coss sections (incl.jumper)
      Solid or stranded mm²  4-16
      Flexible mm²  4-16
      Flexible(+multicorecable end) mm²  4-16
    Torque
      Tightening torque terminal screws M4  Nm  1.2-1.8
       Tightening torque single hole mounting nut M16  Nm  2.0-2.3
     Tightening torque knob screws M3  Nm  0.5-0.7
      Switchingon oroff torque  Nm  0.9-1.3
      General parameters
      Knob positions   12 o’dock OFF,3 o’dock ON(9o’dock OFF,12 o’dock ON)
      BectricalLife Actual   3000 Cydes
    Standard   300 Cydes
      MechanicalLife Actual   10000 Cydes
    Standard   10000 Cydes
      Distance ofcontacts (per pole) mm   8
      Operation temperature   -40 to +85
      Store temperature   -40 to +85
      Pollutiondegree   3
      Overvoltage category   lⅡ
      IP rating of shafte and mounting nut   IP66
    According to IEC/EN60947-3.Utilizationcategory DC-PV1.
      Layers Voltage/current(DC-PV1)
      2/3/4/6/8/10 600Vdc 800Vdc 1000Vdc 1200Vdc 1500Vdc Model
    32 26 13 10 5 LYDS5(6)(7)XX/13/ZY
    40 30 20 12 6 LYDS5(6)(7)XX/20/ZY
    55 45 25 15 8 LYDS5(6)(7)XX/25/ZY
    / 50 40 30 20 LYDS5(6X(7)XX/40/ZY
    1 55 50 40 30 LYDS5(6)(7)XX/50/ZY
      4T/B/S / 32 26 13 LYDS5(6)(7)XX/13/ZY
    / / 40 30 20 LYDS5(6)(7)XX/20/ZY
    / / 55 40 30 LYDS5(6)(7)XX/25/ZY
    / 1 / 45 LYDS5(6)(7)XX/40/ZY
    50 LYDS5(6)(7)XX/50/ZY
    According to AS60947.3.UtilizationcategoryDC-PV2.
      Layers Voltage/current(DC-PV2)
      2/3/4/6/8/10 600Vdc 800Vdc 1000Vdc 1200Vdc 1500Vdc Model
    13 13 6 4 3 LYDS5(6)(7)XX/13/ZY
    20 15 8 6 4 LYDS5(6)(7)XX/20/ZY
    25 23 10 8 5 LYDS5(6)(7)XX/25/ZY
    40 30 20 15 8 LYDS5(6)(7)XX/40/ZY
    50 40 25 18 10 LYDS5(6)(7)XX/50/ZY
      4T/B/S3T/6T/9T / 12 LYDS5(6)(7)XX/13/ZY
    / / 18 1 / LYDS5(6)(7)XX/20/ZY
    / 20 / LYDS5(6)(7)XX/25/ZY
    / / 40 / / LYDS5(6)(7)XX/40/ZY
    / / 50 / / LYDS5(6)(7)XX/50/ZY
    Accordingto UL5081.Utilization category UL.
    Layers Voltage/current(UL508i)
    2/3/4/6/8/10   600VDC    800VDC 1000VDC  Model
      30    30 13  LYDS5(6X(7)XX/13/ZY
      30    30 20  LYDS5(6X(7)XX/20/ZY
      30    30 25  LYDS5(6)(7)XX/25/2Y
      30    30 30  LYDS5(6X(7)XX/30/2Y
    Note*10P products needs to be customized,please kindly contact us if need them

    Product Benefits

    • Ip66, UV Resistance
    • Arcing Time < 3ms
    • Earth Terminal
    • IEC60947-3, AS60947.3
    • 2 Poles, 4 Poles Available(Single | Double String)
    • DC-PV2 / DC-21B: 55A up to 1500VDC

     

    🔹 FAQ – LYDS6 DC Isolator Switch

    1. What type of circuits is LYDS6 designed for?
      DC distribution networks, solar PV string isolations, battery banks, and DC load circuits.

    2. Can this isolator switch safely interrupt DC current?
      Yes. It uses a positive break contact design that minimizes arcing in DC circuits.

    3. What standards does LYDS6 meet?
      Complies with IEC 60947-3 DC switch requirements for safe isolation.

    4. Where is it best installed?
      DC distribution panels, combiner boxes, energy storage cabinets, and inverter input areas.

    5. Does this product support OEM customization?
      Yes — multi-language labels, private-label packaging, and technical custom options are supported.

    Start Customizing Now

    We offer a full range of customised services, working closely with our customers every step of the way, from concept design to final delivery.

    Other&Products

    Our team is always guided by the needs of our customers, providing professional consultation and support to ensure your satisfaction.

    ANYTHING YOU COULDN’T FIND?

    Talk With Our Sales

    We know that every business is unique, so we offer customized services to ensure that our products perfectly match your specific needs:

    • Comprehensive brochure you can download
    • 15 years factory experience
    • Fast delivery
    • OEM&ODM
    • Low price
    • Small MQQ

    SEND US AN EMAIL

    devin@cnspd.com

    Contact Us

    We constantly evaluate and improve our processes to ensure that we are delivering the most efficient and reliable electrical products on the market.