Technical Data
| Main Parameters |
| Model | A | 13 | 20 | 25 | 40 | 50 |
| Rated insulation voltage Ui | V | 1500 | 1500 | 1500 | 1500 | 1500 |
| Rated thermal current Ith | A | 32 | 40 | 55 | 55 | 55 |
| Rated impulse withstand voltage Uimp | V | 8000 |
| Rated short-time withstand current(1s) Icw | A | 780 |
| Rated short-time making capacity Icm | A | 1200 |
| Maximum cable cross sections(ind.jumper) | | |
| Solid or stranded | mm² | 4-16 |
| Flexible | mm² | 4-16 |
| Flexible (+multicore cable end) | mm² | 4-16 |
| Torque | | |
| Tightening torque terminal screws M4. | Nm | 1.2-1.8 |
| Tightening torque single hole mounting nut M16 | Nm | 2.0-2.3 |
| Tightening torque knob screws M3 | Nm | 0.5-0.7 |
| Switching on oroff torque | Nm | 0.9-1.3 |
| General parameters |
| Knob positions | | 12 o’clock OFF,3 o’cock ON(9 o’clock OFF,12 o’dock ON) |
| Electrica Life | Actual | | 3000 Cycles |
| Standard | | 300 Cycles |
| Mechanical Life | Actual | | 10000 Cycles |
| Standard | | 10000 Cycles |
| Distance of contacts (per pole) | mm | 8 |
| Operation temperature | ℃ | -40 to +85 |
| Store temperature | ℃ | -40 to +85 |
| Pollution degree | | 3 |
| Overvoltage category | | Ⅱ |
| IP rating of shafte and mounting nut | | IP66 |
According to IEC/EN60947-3. Utilization category DC-PV1.
| Layers | Voltage/current(DC-PV1) |
| 2/3/4/6/8/10 | 600Vdc | 800Vdc | 1000Vdc | 1200Vdc | 1500Vdc | Model |
| 32 | 26 | 13 | 10 | 5 | LYDS5(6)(7)XX/13/ZY |
| 40 | 30 | 20 | 12 | 6 | LYDS5(6)(7)XX/20/ZY |
| 55 | 45 | 25 | 15 | 8 | LYDS5(6)(7)XX/25/ZY |
| / | 50 | 40 | 30 | 20 | LYDS5(6)(7)XX/40/ZY |
| / | 55 | 50 | 40 | 30 | LYDS5(6)(7)XX/50/ZY |
| 4T/B/S | / | / | 32 | 26 | 13 | LYDS5(6)(7)XX/13/ZY |
| / | / | 40 | 30 | 20 | LYDS5(6)(7)XX/20/ZY |
| / | / | 55 | 40 | 30 | LYDS5(6)(7)XX/25/ZY |
| / | / | / | / | 45 | LYDS5(6)(7)XX/40/ZY |
| / | / | / | / | 50 | LYDS5(6)(7)XX/50/ZY |
According to AS60947.3. Utilization category DC-PV2.
| Layers | Voltage/current(DC-PV2) |
| 2/3/4/6/8/10 | 600Vdc | 800Vdc | 1000Vdc | 1200Vdc | 1500Vdc | Model |
| 13 | 13 | 6 | 4 | 3 | LYDS5(6)(7)XX/13/ZY |
| 20 | 15 | 8 | 6 | 4 | LYDS5(6)(7)XX/20/ZY |
| 25 | 23 | 10 | 8 | 5 | LYDS5(6)(7)XX/25/ZY |
| 40 | 30 | 20 | 15 | 8 | LYDS5(6)(7)XX/40/ZY |
| 50 | 40 | 25 | 18 | 10 | LYDS5(6)(7)XX/50/ZY |
| 4T/B/S/3T/6T/9T | / | / | 12 | / | / | LYDS5(6)(7)XX/13/ZY |
| / | / | 18 | / | / | LYDS5(6)(7)XX/20/ZY |
| / | / | 20 | / | / | LYDS5(6)(7)XX/25/ZY |
| / | / | 40 | / | / | LYDS5(6)(7)XX/40/ZY |
| / | / | 50 | / | / | LYDS5(6)(7)XX/50/ZY |
According to UL508I. Utilization category UL.
| Layers | Voltage/current(UL 508i) |
| 2/3/4/6/8/10 | 600VDC | 800VDC | 1000VDC | Model |
| 30 | 30 | 13 | LYDS5(6)(7)XX/13/ZY |
| 30 | 30 | 20 | LYDS5(6)(7)XX/20/ZY |
| 30 | 30 | 25 | LYDS5(6)(7)XX/25/ZY |
| 30 | 30 | 30 | LYDS5(6)(7)XX/30/ZY |
Note* 10P products needs to be customized, please kindly contact us if need them