Artikel Nr.: LY1-D20M/3(S)+1

Key Specifications:

Modell
LY1-D20M/3(S)+1

Typ
Class II+III / Type 2+3 AC SPD

System
3P+N Three-Phase System

Schutzmodus
L-N / N-PE

Protection Elements
High-Energy MOV + GDT

Voltage Options
75V / 150V / 275V / 320V AC

In / Imax
10kA / 20kA, L-N and N-PE

Montage
35mm DIN Rail

Jetzt zitieren

    Compact Type 2+3 AC Surge Protection for 3P+N Systems

    LY1-D20M/3(S)+1 is a compact 3P+N pluggable Type 2+3 AC surge protective device for three-phase plus neutral systems. Its coordinated MOV and GDT structure provides L-N and N-PE surge protection with 10kA nominal discharge current and 20kA maximum discharge current.


    Class II+III / Type 2+3 downstream surge protection

    Compact 3P+N configuration with L-N and N-PE protection

    Coordinated high-energy MOV and GDT protection technology

    Pluggable modules with visual indication and optional remote contact

    Suitable Applications

    LY1-D20M/3(S)+1 is suitable for compact three-phase plus neutral systems requiring coordinated Type 2+3 surge protection in limited DIN-rail space.

    Unterverteilerschränke

    For downstream protection in compact commercial and industrial 3P+N distribution boards.

    Industrial Control Panels

    Suitable for machinery controls, factory automation cabinets, HVAC panels, and production equipment.

    🏢

    Commercial Facilities

    Helps protect building controls, office distribution cabinets, retail systems, and sensitive commercial loads.

    Solar Inverter AC Panels

    For three-phase solar inverter AC-side panels when the selected Uc version matches the system voltage.

    FAQ

    Common questions about LY1-D20M/3(S)+1 compact 3P+N pluggable Type 2+3 AC surge protective device selection.

    What is LY1-D20M/3(S)+1 used for?

    LY1-D20M/3(S)+1 is used for downstream and final-distribution surge protection in compact three-phase plus neutral AC systems.

    What does 3P+N mean?

    3P+N means the SPD is designed for three phase conductors plus neutral, using MOV protection on the L-N paths and a GDT protection path between N-PE.

    Is LY1-D20M/3(S)+1 a Type 2 or Type 3 SPD?

    It is classified as Class II+III / Type 2+3, making it suitable for coordinated downstream and final-distribution surge protection.

    Does this SPD use MOV or GDT protection?

    It uses a coordinated MOV and GDT structure. MOV modules protect the L-N paths, while the GDT provides the N-PE protection path.

    What discharge current ratings does it provide?

    It provides 10kA nominal discharge current and 20kA maximum discharge current on both the L-N and N-PE protection paths.

    What should be confirmed before ordering?

    Confirm the nominal L-N voltage, required Uc and Up level, 3P+N wiring arrangement, 125A maximum backup-fuse coordination, conductor size, DIN-rail space, and optional remote-contact requirement.

    Technische Daten

    Electrical, mechanical, environmental, and installation data for LY1-D20M/3(S)+1 compact 3P+N pluggable Type 2+3 AC surge protective device selection.

    Parameter75V150V275V320V
    IEC Elektrisch
    Nominal AC Voltage Uo / Un60V120V230V230V
    Maximum Continuous Operating Voltage Uc, L-N75V150V275V320V
    Maximum Continuous Operating Voltage Uc, N-PE255V
    Nominal Discharge Current In, L-N / N-PE10kA / 10kA, 8/20μs
    Maximum Discharge Current Imax, L-N / N-PE20kA / 20kA, 8/20μs
    Voltage Protection Level Up, L-N / N-PE0.2kV / 1.5kV0.6kV / 1.5kV1.3kV / 1.5kV1.5kV / 1.5kV
    Follow Current Interrupt Rating Ifi, N-PE100 ARMEN
    Response Time tA, L-N / N-PE<25ns / <100ns
    Back-Up Fuse Max.125A gL / gG
    Short-Circuit Current Rating ISCCR, L-N10kA
    TOV Withstand 5s UT, L-N90V180V335V335V
    TOV 120min UT, L-N115V230V440V440V
    TOV ModeWiderstandsfähigSicheres VersagenSicheres VersagenSicheres Versagen
    TOV Withstand 200ms UT, N-PE1200V
    Mechanik und Umwelt
    Betriebstemperaturbereich-40°C to +70°C
    Zulässige Betriebsfeuchtigkeit5%–95%
    Atmospheric Pressure / Altitude80kPa–106kPa / -500m to 2000m
    Klemmenschrauben-Drehmoment39.9lbf·in / 4.5Nm
    Conductor Cross Section Max.2 AWG solid/stranded; 4 AWG flexible; 35mm² solid/stranded; 25mm² flexible
    Montage35mm DIN Rail, EN 60715
    Grad des SchutzesIP20, built-in
    Material des GehäusesThermoplastic, UL94 V-0
    Thermischer SchutzJa
    Betriebszustand/StörungsanzeigeGreen: OK / Red: Defect
    Remote ContactsOptional
    RC-SchaltleistungAC 250V / 0.5A; DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
    RC Conductor Cross Section Max.16 AWG solid / 1.5mm² solid
    Selection Note:
    Confirm the nominal L-N voltage, required Uc and Up level, 3P+N wiring arrangement, 125A maximum backup fuse, conductor size, DIN-rail space, and optional remote contact before ordering.

    ■ Interne Konfiguration


    ■ Abmessungen und Verpackung


    ■ Anschlussschema

    Jetzt mit der Anpassung beginnen

    Wir bieten ein umfassendes Angebot an maßgeschneiderten Dienstleistungen und arbeiten bei jedem Schritt eng mit unseren Kunden zusammen, vom Konzept bis zur Auslieferung.

    Andere&Produkte

    Unser Team orientiert sich stets an den Bedürfnissen unserer Kunden und bietet professionelle Beratung und Unterstützung, um Ihre Zufriedenheit zu gewährleisten.

    ALLES, WAS SIE NICHT FINDEN KONNTEN?

    Sprechen Sie mit unserem Vertrieb

    Da wir wissen, dass jedes Unternehmen einzigartig ist, bieten wir maßgeschneiderte Dienstleistungen an, um sicherzustellen, dass unsere Produkte perfekt auf Ihre spezifischen Bedürfnisse zugeschnitten sind:

    • Umfassende Broschüre zum Herunterladen
    • 15 Jahre Erfahrung in der Fabrik
    • Schnelle Lieferung
    • OEM&ODM
    • Niedriger Preis
    • Kleiner MQQ

    SENDEN SIE UNS EINE E-MAIL

    devin@cnspd.com

    Kontakt

    Wir bewerten und verbessern unsere Prozesse ständig, um sicherzustellen, dass wir die effizientesten und zuverlässigsten Elektroprodukte auf dem Markt liefern.