Numéro d'article : LY10 Din-Rail type plug-in DATA SIGNAL/DC SURGE PROTECTIVE DEVICE

Key Specifications:

Modèle
LY10

Type de produit
Data Signal Surge Protector

Tension de fonctionnement nominale
12V / 24V / 48V DC

Maximum Continuous Voltage
15V / 30V / 60V DC

Rated Load Current
500mA

Transmission Rate
Up to 10Mbps

Insertion Loss
≤ 0.2dB

Installation
DIN-Rail Plug-In Design

Citer maintenant

    Reliable Surge Protection for RS485 and Industrial Signal Lines

    LY10 is a DIN-rail pluggable surge protective device designed for RS485, telemetry, remote-control, and industrial communication lines. Installed in series before sensitive equipment, it helps suppress induced transient overvoltage while maintaining signal transmission rates up to 10Mbps and insertion loss of no more than 0.2dB.


    Designed for RS485 and industrial communication lines

    12V, 24V, and 48V signal-system versions

    Up to 10Mbps transmission with ≤0.2dB insertion loss

    Compact DIN-rail plug-in design for control cabinets

    Suitable Applications

    LY10 is suitable for low-voltage data and control circuits that require surge protection without significantly affecting signal transmission.

    RS485 Networks

    Protects RS485 communication links used between industrial controllers, meters, sensors, and field devices.

    PLC & Automation Systems

    Helps protect PLC communication ports, automation controllers, and distributed I/O signal lines.

    📡

    Telemetry & Remote Control

    Suitable for telemetry, remote monitoring, remote-control, and SCADA signal circuits.

    Sensors & Field Instruments

    Protects low-voltage sensors, transmitters, meters, and field-instrument signal interfaces.

    FAQ

    Common questions about LY10 DIN-rail pluggable data signal surge protector selection and installation.

    What is the LY10 signal surge protector used for?

    LY10 is installed in series with low-voltage data or control lines to help suppress induced transient overvoltage before it reaches sensitive communication and automation equipment.

    Is LY10 suitable for RS485 communication lines?

    Yes. It is designed for RS485 and similar industrial data lines used by PLCs, meters, sensors, automation controllers, and remote-monitoring equipment.

    Which operating voltage should be selected?

    Select the 12V, 24V, or 48V version according to the normal operating voltage of the protected signal circuit. The selected maximum continuous voltage must remain above the circuit’s normal operating voltage.

    Will the LY10 affect data transmission?

    The listed transmission rate is up to 10Mbps and the listed insertion loss is no more than 0.2dB. Compatibility should still be confirmed against the actual communication protocol, impedance, and cable length.

    How is the LY10 installed?

    It is mounted on a DIN rail and connected in series ahead of the protected equipment. The protected and unprotected sides must follow the wiring diagram, and the grounding conductor should be kept as short as practical.

    What should be confirmed before ordering?

    Confirm the signal voltage, maximum continuous voltage, line current, communication protocol, transmission rate, number of conductors, terminal arrangement, grounding method, and required surge withstand level.

    Données techniques

    Electrical, transmission, surge-withstand, and installation data for LY10 DIN-rail pluggable data signal surge protector selection.

    Paramètres12V Version24V Version48V Version
    Signal Circuit Ratings
    ModèleLY10
    Product ConfigurationDIN-Rail Plug-In Type
    Tension de fonctionnement nominale12V DC24V DC48V DC
    Maximum Continuous Operating Voltage15V DC30V DC60V DC
    Rated Load Current500mA
    Surge & Transmission Performance
    Listed Surge Withstand Capacity10kV / 5kA*
    Clamping Voltage, Line-to-Line, 1.2/50μs60V80V160V
    Maximum Transmission Rate10Mbps
    Insertion Loss≤ 0.2dB
    Installation
    Interface TypeConnection Terminal
    Mounting MethodDIN-Rail Mounting
    Installation MethodSeries Connection Before Protected Equipment
    Degré de protectionIP20
    Selection Note:
    Match the LY10 operating-voltage version to the protected signal circuit. Also confirm the communication protocol, line current, transmission rate, number of conductors, grounding method, terminal arrangement, and wiring direction before ordering.

    *Parameter Check:
    The current page lists the surge withstand value only as “10kV & 5kA” without identifying the complete test waveforms or protection modes. Confirm these details against the official test report or datasheet before using the value in certificates or technical quotations.

    Commencez à personnaliser maintenant

    Nous offrons une gamme complète de services personnalisés, en travaillant en étroite collaboration avec nos clients à chaque étape, de la conception à la livraison finale.

    Autres&Produits

    Notre équipe est toujours guidée par les besoins de nos clients, fournissant une consultation et un soutien professionnels pour assurer votre satisfaction.

    TOUT CE QUE VOUS N'AVEZ PAS PU TROUVER?

    Parlez avec nos vendeurs

    Nous savons que chaque entreprise est unique, c'est pourquoi nous proposons des services personnalisés afin de garantir que nos produits répondent parfaitement à vos besoins spécifiques :

    • Brochure complète à télécharger
    • 15 ans d'expérience en usine
    • Livraison rapide
    • OEM&ODM
    • Prix bas
    • Petit MQQ

    ENVOYEZ-NOUS UN COURRIEL

    devin@cnspd.com

    Nous contacter

    Nous évaluons et améliorons constamment nos processus pour nous assurer que nous fournissons les produits électriques les plus efficaces et les plus fiables du marché.