Numéro d'article : LY26-XF Signal SPD

Key Specifications:

Modèle
LY26-XF

Type de produit
Waterproof Explosion-Proof Signal SPD

Rated Voltage Options
5V / 12V / 24V / 48V / 110V / 220V

Maximum Continuous Voltage
6V / 15V / 30V / 50V / 230V / 420V

Courant de décharge nominal
In 5kA, 8/20μs

Temps de réponse
≤ 1ns

Insertion Loss
≤ 0.3dB

Protection Circuits
Single-Channel or Dual-Channel

Citer maintenant

    Waterproof Surge Protection for Outdoor and Hazardous Signal Lines

    LY26-XF is a waterproof and explosion-proof signal surge protective device designed for RS485 data transmission, industrial communication, and field-control lines. Its multistage semiconductor protection provides fast transient suppression, low residual voltage, and low insertion loss for sensitive equipment installed outdoors or in demanding industrial environments.


    Waterproof enclosure for outdoor signal-line installations

    Suitable for RS485, communication, and control signal lines

    Fast response time of no more than 1ns

    Single-channel and dual-channel protection options

    Suitable Applications

    LY26-XF is designed for outdoor and industrial signal circuits that require reliable surge protection, moisture resistance, and a robust enclosed construction.

    RS485 Control Lines

    Protects RS485 data transmission and industrial control circuits exposed to induced surges.

    🏭

    Chemical Plants

    Suitable for field-control and data lines in chemical workshops and other demanding industrial locations.

    Fuel & Gas Facilities

    For signal lines in gas stations, oil depots, gas storage areas, and fuel-handling facilities.

    📹

    Outdoor Security Systems

    Helps protect outdoor monitoring, alarm, access-control, firefighting, and security signal circuits.

    FAQ

    Common questions about LY26-XF waterproof and explosion-proof signal-line surge protection.

    What is the LY26-XF used for?

    LY26-XF is designed to protect RS485, data communication, and field-control signal lines against lightning-induced and switching transient overvoltage.

    Is LY26-XF suitable for outdoor installation?

    Yes. It uses a waterproof enclosed housing and is intended for outdoor signal-line applications where moisture and environmental exposure must be considered.

    Which voltage version should be selected?

    Select the 5V, 12V, 24V, 48V, 110V, or 220V version according to the normal operating voltage of the protected signal circuit and the corresponding maximum continuous voltage.

    Does LY26-XF support single-channel and dual-channel protection?

    Yes. The product is available with single-channel protection for terminals 1 and 2, or dual-channel protection for terminals 1, 2, 3, and 4.

    Will the protector significantly affect the signal?

    The listed insertion loss is no more than 0.3dB. Final compatibility should still be checked against the actual protocol, line impedance, transmission distance, and signal frequency.

    What should be confirmed before ordering?

    Confirm the signal voltage, maximum continuous voltage, number of protected channels, wiring arrangement, communication protocol, installation environment, grounding method, enclosure requirements, and required certification.

    Données techniques

    Electrical, signal-performance, enclosure, and circuit-configuration data for LY26-XF waterproof explosion-proof signal surge protector selection.

    Paramètres5V12V24V48V110V220V
    Signal Circuit Ratings
    ModèleLY26-XF
    Rated Operating Voltage Un5V12V24V48V110V220V
    Maximum Continuous Operating Voltage Uc6V15V30V50V230V420V
    Surge & Signal Performance
    Nominal Discharge Current In, 8/20μs5kA
    Temps de réponse≤ 1ns
    Insertion Loss≤ 0.3dB
    Enclosure & Circuit Configuration
    HousingWaterproof and Explosion-Proof Enclosure
    Single-Channel Protection CircuitTerminals 1 and 2
    Dual-Channel Protection CircuitTerminals 1, 2, 3 and 4
    Typical Protected LinesRS485, Data Communication and Field-Control Signal Lines
    Installation ZoneSignal equipment interface from LPZ 1 to LPZ 3
    Selection Note:
    Select the voltage version according to the normal operating voltage and maximum continuous voltage of the protected signal line. Confirm the single-channel or dual-channel wiring arrangement, communication protocol, signal frequency, grounding method, enclosure installation, and hazardous-area requirements before ordering.

    Certification Note:
    “Explosion-proof” requirements vary by country and application. Confirm the exact explosion-protection certificate, marking, gas group, temperature class, enclosure rating, and installation method before using the product in a regulated hazardous area.

    Commencez à personnaliser maintenant

    Nous offrons une gamme complète de services personnalisés, en travaillant en étroite collaboration avec nos clients à chaque étape, de la conception à la livraison finale.

    Autres&Produits

    Notre équipe est toujours guidée par les besoins de nos clients, fournissant une consultation et un soutien professionnels pour assurer votre satisfaction.

    TOUT CE QUE VOUS N'AVEZ PAS PU TROUVER?

    Parlez avec nos vendeurs

    Nous savons que chaque entreprise est unique, c'est pourquoi nous proposons des services personnalisés afin de garantir que nos produits répondent parfaitement à vos besoins spécifiques :

    • Brochure complète à télécharger
    • 15 ans d'expérience en usine
    • Livraison rapide
    • OEM&ODM
    • Prix bas
    • Petit MQQ

    ENVOYEZ-NOUS UN COURRIEL

    devin@cnspd.com

    Nous contacter

    Nous évaluons et améliorons constamment nos processus pour nous assurer que nous fournissons les produits électriques les plus efficaces et les plus fiables du marché.