Nomor Item: LYB-12.5/275 3(S)+1

Spesifikasi Kunci:

Model
LY1-B25/3(S)+1

Tipe
Class I+II / Type 1+2 AC SPD

Poles
3P+N Monoblock Design

Network System
TT / TN-S

Protection Mode
L-N / N-PE

Iimp
25kA / 100kA, 10/350μs

In / Imax
25kA / 100kA In, 100kA Imax

Pemasangan
Rel DIN 35mm

Dapatkan Penawaran Sekarang

    High-Energy Type 1+2 AC Surge Protection for 3P+N Systems

    LY1-B25/3(S)+1 is a monoblock 3P+N Type 1+2 AC surge protective device designed for TT and TN-S low-voltage distribution systems. It combines high-energy MOV and GDT protection elements to protect three-phase plus neutral incoming power circuits from lightning surges and transient overvoltage.


    Class I+II / Type 1+2 AC SPD for main distribution board protection

    3P+N protection design for TT and TN-S network systems

    High-energy MOV and GDT elements for L-N and N-PE protection

    100kA total discharge current for high-energy surge protection

    Suitable Applications

    LY1-B25/3(S)+1 is suitable for TT and TN-S three-phase plus neutral AC systems where Type 1+2 surge protection is required at the incoming power side or main distribution level.

    Main Distribution Boards

    For incoming surge protection in 3P+N AC distribution boards and low-voltage panels.

    🏢

    Gedung Komersial

    Helps protect commercial building power systems with three-phase plus neutral distribution.

    Industrial Power Panels

    Suitable for industrial low-voltage panels requiring high-energy Type 1+2 surge protection.

    Solar AC Side Panels

    Can be used on the AC side of solar systems when voltage, network system, and protection mode match the design.

    FAQ

    Common questions about LY1-B25/3(S)+1 3P+N monoblock AC surge protective device selection and application.

    What is LY1-B25/3(S)+1 used for?

    LY1-B25/3(S)+1 is used for Type 1+2 AC surge protection in TT and TN-S three-phase plus neutral systems. It protects L-N and N-PE paths at the main distribution board or incoming power side.

    What does 3P+N mean?

    3P+N means the SPD is designed for three-phase plus neutral systems, with protection paths between L-N and N-PE depending on the system design.

    Apa peringkat lonjakan yang disediakan oleh SPD ini?

    The product provides 25kA / 100kA impulse discharge current Iimp, 25kA / 100kA nominal discharge current In, 100kA maximum discharge current Imax, and 100kA total discharge current Itotal.

    What is the role of MOV and GDT in this SPD?

    The MOV helps clamp transient overvoltage quickly, while the GDT is used for high-energy discharge, especially in the N-PE protection path.

    Does this model support remote signalling?

    Yes. The “S” version can include optional remote contact for SPD status monitoring. Please confirm this requirement before ordering.

    What should be confirmed before ordering?

    Please confirm system voltage, TT or TN-S network system, L-N / N-PE protection mode, backup fuse, installation space, wiring cross-section, and remote signalling requirement before ordering.

    Data Teknis

    Detailed electrical, mechanical, and installation data for LY1-B25/3(S)+1 3P+N monoblock AC surge protective device selection.

    Parameter 150V 275V 320V 385V
    Nominal AC Voltage Uo / Un 120V 230V 230V 230V
    Maximum Continuous Operating Voltage Uc (L-N) 150V 275V 320V 385V
    Maximum Continuous Operating Voltage Uc (N-PE) 255V
    Nominal Discharge Current In, 8/20μs (L-N / N-PE) 25kA / 100kA
    Maximum Discharge Current Imax, 8/20μs 100kA
    Impulse Discharge Current Iimp, 10/350μs (L-N / N-PE) 25kA / 100kA
    Total Discharge Current Itotal, 10/350μs 100kA
    Specific Energy W/R (L-N / N-PE) 156 kJ / Ω / 2.5 MJ / Ω
    Charge Q (L-N / N-PE) 12.5 As / 50 As
    Voltage Protection Level Up (L-N / N-PE) 1.0kV / 1.5kV 1.5kV / 1.5kV 1.6kV / 1.5kV 1.8kV / 1.5kV
    Follow Current Interrupt Rating Ifi (N-PE) 100 ARMS
    Response Time tA (L-N / N-PE) < 25 ns / < 100 ns
    Back-Up Fuse Max. 315A gL / gG
    Short-Circuit Current Rating ISCCR (L-N) 50kA
    TOV Withstand 5s UT (L-N) 180V 335V 335V 335V
    TOV 120min UT (L-N) 230V 440V 440V 440V
    TOV Withstand 200ms UT (N-PE) 1200V
    Operating Temperature -40°C to +70°C
    Conductor Cross Section 35mm² solid / stranded, 25mm² flexible
    Terminal Screw Torque 4.5 Nm
    Pemasangan 35mm DIN Rail, EN 60715
    Derajat Perlindungan IP20, built-in
    Bahan Perumahan Thermoplastic, UL 94 V-0
    Operating State / Fault Indication Green: OK / Red: Defect
    Remote Contact Optional
    Selection Note:
    Please confirm system voltage, TT or TN-S network system, L-N / N-PE protection mode, backup fuse, installation space, wiring cross-section, and remote signalling requirement before ordering.

    ■ Internal Configuration


    ■ Dimensions & Packaging


    ■ Connection Diagram

    Mulai Kustomisasi Sekarang

    Kami menawarkan berbagai layanan yang disesuaikan, bekerja sama dengan pelanggan kami di setiap langkah, dari desain konsep hingga pengiriman akhir.

    Produk Lainnya

    Tim kami selalu dipandu oleh kebutuhan pelanggan kami, memberikan konsultasi dan dukungan profesional untuk memastikan kepuasan Anda.

    APA YANG TIDAK BISA ANDA TEMUKAN?

    Bicaralah Dengan Penjualan Kami

    Kami tahu bahwa setiap bisnis unik, jadi kami menawarkan layanan kustom untuk memastikan bahwa produk kami cocok sempurna dengan kebutuhan spesifik Anda:

    • Brosur komprehensif yang dapat Anda unduh
    • Pengalaman pabrik selama 15 tahun
    • Pengiriman cepat
    • OEM&ODM
    • Harga rendah
    • MQQ kecil

    KIRIM KEPADA KAMI EMAIL

    devin@cnspd.com

    Hubungi Kami

    Kami terus menilai dan meningkatkan proses kami untuk memastikan bahwa kami memberikan produk listrik yang paling efisien dan dapat diandalkan di pasar.