Type 1+2 Surge Protection for 1000V DC Solar PV Systems
LY1-C40PV/2(S) 1000V is a two-pole pluggable Type 1+2 DC surge protective device designed for photovoltaic strings, combiner boxes, inverter DC inputs, and high-voltage DC distribution systems. Its high-energy MOV modules provide protection for both positive and negative DC conductors, with 20kA nominal discharge current, 40kA maximum discharge current, and a listed 6.25kA impulse current.
Class I+II / Type 1+2 protection for 1000V DC systems
Two-pole protection for DC+ and DC− conductors
20kA In, 40kA Imax, and 6.25kA Iimp capability
Replaceable cartridges with visual status indication
Aplikasi Yang Sesuai
LY1-C40PV/2(S) 1000V is designed for high-voltage photovoltaic and DC power systems requiring coordinated protection of both positive and negative conductors.
PV String Combiner Boxes
Protects 1000V DC photovoltaic strings and combiner-box circuits against lightning and switching surges.
PV Inverter DC Inputs
Suitable for protecting the DC input side of string, hybrid, and central solar inverters.
DC Distribution Cabinets
For 1000V DC distribution cabinets, switching panels, and high-voltage DC equipment circuits.
Energy Storage DC Systems
Suitable for compatible battery charging cabinets and energy-storage DC circuits up to 1000V DC.
FAQ
Common questions about LY1-C40PV/2(S) 1000V two-pole pluggable Type 1+2 DC surge protective device selection and installation.
Apa itu LY1-C40PV/2(S) 1000V digunakan untuk?
Ini dirancang untuk melindungi sistem fotovoltaik dan sistem listrik DC 1000V dari lonjakan yang disebabkan oleh petir dan overvoltage transien yang dihasilkan oleh saklar. Lokasi yang umum termasuk kotak penggabung PV, input DC inverter, dan kabinet distribusi DC.
Apakah ini adalah SPD DC Tipe 1+2?
Yes. The product is classified as Class I+II / Type 1+2 and lists both an 8/20μs discharge-current rating and a 10/350μs impulse-current rating.
Apa rating arus pengeluaran yang disediakan?
Ini menyediakan arus pelepasan nominal 20kA In, arus pelepasan maksimum 40kA Imax, dan arus pelepasan impuls terdaftar 6.25kA Iimp.
Apa yang dilindungi oleh konfigurasi dua kutub?
Konfigurasi dua kutub menyediakan jalur perlindungan lonjakan terpisah untuk konduktor DC positif dan negatif relatif terhadap tanah pelindung.
Bisakah kartrid perlindungan diganti?
Yes. The pluggable design allows individual protection cartridges to be inspected or replaced without removing the permanently wired base.
Apa yang harus dikonfirmasi sebelum memesan?
Confirm the maximum PV system voltage, 1000V DC operating requirement, DC+ and DC− protection arrangement, required Up level, backup-fuse coordination, conductor size, DIN-rail space, and remote-contact requirement.