Nomor Item: LY1-B25/2(S)

Spesifikasi Kunci:

Model
LY1-B25/2(S)

Tipe
Class I+II / Type 1+2 AC SPD

Poles
2P Monoblock Design

Voltage Options
150V / 275V / 320V / 385V / 440V AC

Iimp
25kA, 10/350μs

In / Imax
25kA / 100kA, 8/20μs

Total Discharge Current
Itotal 50kA, 10/350μs

Pemasangan
Rel DIN 35mm

Dapatkan Penawaran Sekarang

    High-Energy Type 1+2 AC Surge Protection for Main Distribution Boards

    LY1-B25/2(S) is a monoblock 2-pole Type 1+2 AC surge protective device designed for main distribution boards and low-voltage AC power systems. With 25kA impulse discharge current, 100kA maximum discharge current, and 50kA total discharge current, it helps protect incoming power circuits from lightning surges and transient overvoltage.


    Class I+II / Type 1+2 AC SPD for main distribution board protection

    25kA Iimp, 25kA In, 100kA Imax, and 50kA Itotal surge rating

    2-pole monoblock design for compact AC surge protection installation

    Suitable for TN-S network systems and L-PE / N-PE protection modes

    Suitable Applications

    LY1-B25/2(S) is suitable for AC power systems where high-energy Type 1+2 surge protection is required at the incoming power side or main distribution level.

    Main Distribution Boards

    For incoming AC power protection in main distribution boards and low-voltage panels.

    🏢

    Gedung Komersial

    Helps protect building power distribution systems from lightning-induced surges.

    Industrial Power Panels

    Suitable for industrial low-voltage panels requiring high-energy surge protection.

    Solar AC Side Panels

    Can be used on the AC side of solar systems when voltage and protection mode match the design.

    FAQ

    Common questions about LY1-B25/2(S) 2-pole monoblock AC surge protective device selection and application.

    What is LY1-B25/2(S) used for?

    LY1-B25/2(S) is used for AC surge protection at the main distribution board or incoming power side. It helps limit lightning surges and transient overvoltage in low-voltage AC systems.

    What is the difference between LY1-B25/1(S) and LY1-B25/2(S)?

    LY1-B25/1(S) is a single-pole version, while LY1-B25/2(S) is a 2-pole monoblock SPD. The 2-pole version is suitable for applications requiring two-pole protection and includes a total discharge current rating of 50kA.

    Apa peringkat lonjakan yang disediakan oleh SPD ini?

    LY1-B25/2(S) provides 25kA impulse discharge current Iimp, 25kA nominal discharge current In, 100kA maximum discharge current Imax, and 50kA total discharge current Itotal.

    Which network system is this model suitable for?

    This model is suitable for TN-S network systems when the protection mode, voltage rating, and system design match the application requirements.

    Does this model support remote signalling?

    Yes. The “S” version can include optional remote contact for SPD status monitoring. Please confirm this requirement before ordering.

    What should be confirmed before ordering?

    Please confirm system voltage, network system, protection mode, backup fuse, installation space, wiring cross-section, and remote signalling requirement before ordering.

    Data Teknis

    Detailed electrical, mechanical, and installation data for LY1-B25/2(S) 2-pole monoblock AC surge protective device selection.

    Parameter 150V 275V 320V 385V 440V
    Nominal AC Voltage Uo / Un 120V 230V 230V 230V 400V
    Maximum Continuous Operating Voltage Uc 150V 275V 320V 385V 440V
    Nominal Discharge Current In, 8/20μs 25kA
    Maximum Discharge Current Imax, 8/20μs 100kA
    Impulse Discharge Current Iimp, 10/350μs 25kA
    Total Discharge Current Itotal, 10/350μs 50kA
    Specific Energy W/R 156 kJ / Ω
    Charge Q 12.5 As
    Voltage Protection Level Up 1.0kV 1.5kV 1.6kV 1.8kV 2.0kV
    Response Time tA < 25 ns
    Back-Up Fuse Max. 315A gL / gG
    Short-Circuit Current Rating ISCCR 50kA
    Operating Temperature -40°C to +70°C
    Operating Humidity 5%–95%
    Conductor Cross Section 35mm² solid / stranded, 25mm² flexible
    Terminal Screw Torque 4.5 Nm
    Pemasangan 35mm DIN Rail, EN 60715
    Derajat Perlindungan IP20, built-in
    Bahan Perumahan Thermoplastic, UL 94 V-0
    Operating State / Fault Indication Green: OK / Red: Defect
    Remote Contact Optional
    Selection Note:
    Please confirm system voltage, network system, protection mode, backup fuse, installation space, wiring cross-section, and remote signalling requirement before ordering.

    ■ Internal Configuration


    ■ Dimensions & Packaging


    ■ Connection Diagram

    Mulai Kustomisasi Sekarang

    Kami menawarkan berbagai layanan yang disesuaikan, bekerja sama dengan pelanggan kami di setiap langkah, dari desain konsep hingga pengiriman akhir.

    Produk Lainnya

    Tim kami selalu dipandu oleh kebutuhan pelanggan kami, memberikan konsultasi dan dukungan profesional untuk memastikan kepuasan Anda.

    APA YANG TIDAK BISA ANDA TEMUKAN?

    Bicaralah Dengan Penjualan Kami

    Kami tahu bahwa setiap bisnis unik, jadi kami menawarkan layanan kustom untuk memastikan bahwa produk kami cocok sempurna dengan kebutuhan spesifik Anda:

    • Brosur komprehensif yang dapat Anda unduh
    • Pengalaman pabrik selama 15 tahun
    • Pengiriman cepat
    • OEM&ODM
    • Harga rendah
    • MQQ kecil

    KIRIM KEPADA KAMI EMAIL

    devin@cnspd.com

    Hubungi Kami

    Kami terus menilai dan meningkatkan proses kami untuk memastikan bahwa kami memberikan produk listrik yang paling efisien dan dapat diandalkan di pasar.