Nomor Item: LY1-C40/1(S)

Spesifikasi Kunci:

Model
LY1-C40/1(S)

Tipe
Class II / Type 2 AC SPD

Konfigurasi Tiang
1P Single-Pole Design

Protection Element
High-Energy MOV

Voltage Options
75V / 150V / 275V / 320V / 385V / 440V AC

In / Imax
20kA / 40kA, 8/20μs

Impulse Current
Iimp 7kA, 10/350μs

Pemasangan
Rel DIN 35mm

Dapatkan Penawaran Sekarang

    Reliable Type 2 AC Surge Protection for Distribution Circuits

    LY1-C40/1(S) is a single-pole pluggable Type 2 AC surge protective device designed for low-voltage distribution boards and equipment panels. Its high-energy MOV module provides fast transient-voltage limitation with 20kA nominal discharge current, 40kA maximum discharge current, and a replaceable cartridge for easier maintenance.


    Class II / Type 2 protection for low-voltage AC circuits

    20kA In and 40kA Imax surge discharge capability

    75V to 440V AC versions for different system requirements

    Pluggable cartridge with visual indication and optional remote contact

    Suitable Applications

    LY1-C40/1(S) is suitable for low-voltage AC circuits requiring modular Type 2 surge protection in distribution boards, control cabinets, and equipment power systems.

    Papan Distribusi

    For Type 2 surge protection in residential, commercial, and industrial distribution boards.

    Control Cabinets

    Suitable for machinery controls, automation cabinets, HVAC systems, and equipment panels.

    🏢

    Commercial Power Systems

    Helps protect offices, retail facilities, and building electrical systems from transient overvoltage.

    Solar AC Panels

    For solar inverter AC-side panels when the selected Uc rating matches the system voltage.

    FAQ

    Common questions about LY1-C40/1(S) single-pole pluggable Type 2 AC surge protective device selection and installation.

    What is LY1-C40/1(S) used for?

    LY1-C40/1(S) is used to limit transient overvoltage in low-voltage AC distribution circuits. It can be installed as a single-pole protection module or combined with matching modules for a multi-pole arrangement.

    Is LY1-C40/1(S) a Type 2 SPD?

    Yes. LY1-C40/1(S) is classified as a Class II / Type 2 AC surge protective device for low-voltage distribution systems.

    What discharge current ratings does it provide?

    It provides 20kA nominal discharge current In, 40kA maximum discharge current Imax, and a listed 7kA impulse-current rating.

    What voltage options are available?

    Maximum continuous operating voltage options include 75V, 150V, 275V, 320V, 385V, and 440V AC. The correct version must be selected according to the nominal system voltage.

    What is the benefit of the pluggable design?

    The replaceable cartridge allows the surge module to be inspected or replaced without removing the permanently wired base, reducing maintenance time.

    What should be confirmed before ordering?

    Confirm the nominal system voltage, required Uc and Up level, pole configuration, 125A maximum backup-fuse coordination, conductor size, DIN-rail space, and remote-contact requirement.

    Data Teknis

    Electrical, mechanical, environmental, and installation data for LY1-C40/1(S) single-pole pluggable Type 2 AC surge protective device selection.

    Parameter 75V 150V 275V 320V 385V 440V
    Listrik IEC
    Nominal AC Voltage Uo / Un 60V 120V 230V 230V 230V 400V
    Maximum Continuous Operating Voltage Uc 75V 150V 275V 320V 385V 440V
    Nominal Discharge Current In, 8/20μs 20kA
    Maximum Discharge Current Imax, 8/20μs 40kA
    Impulse Current Iimp, 10/350μs 7kA
    Voltage Protection Level Up 0.4kV 1.0kV 1.5kV 1.6kV 1.8kV 2.0kV
    Response Time tA <25ns
    Back-Up Fuse Max. 125A gL / gG
    Short-Circuit Current Rating ISCCR 25kA / 50kA
    TOV Withstand 5s UT 90V 180V 335V 335V 335V 580V
    TOV 120min UT 115V 230V 440V 440V 440V 765V
    TOV Mode Menahan Menahan Kegagalan Aman Kegagalan Aman Kegagalan Aman Kegagalan Aman
    Mechanical & Environmental
    Operating Temperature Range -40°F to +158°F [-40°C to +70°C]
    Permissible Operating Humidity 5%–95%
    Atmospheric Pressure / Altitude 80kPa–106kPa / -500m to 2000m
    Terminal Screw Torque 39.9 lbf·in [4.5Nm]
    Conductor Cross Section Max. 2 AWG solid/stranded; 4 AWG flexible; 35mm² solid/stranded; 25mm² flexible
    Pemasangan 35mm DIN Rail, EN 60715
    Derajat Perlindungan IP20, built-in
    Bahan Perumahan Thermoplastic, UL94 V-0
    Perlindungan Termal Ya
    Operating State / Fault Indication Green: OK / Red: Defect
    Remote Contacts Optional
    RC Switching Capacity AC 250V / 0.5A; DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
    RC Conductor Cross Section Max. 16 AWG solid / 1.5mm² solid
    Selection Note:
    Confirm the nominal system voltage, required Uc and Up level, pole configuration, 125A maximum backup fuse, conductor size, DIN-rail space, and optional remote contact before ordering.

    ■ Internal Configuration


    ■ Dimensions & Packaging


    ■ Connection Diagram

    Mulai Kustomisasi Sekarang

    Kami menawarkan berbagai layanan yang disesuaikan, bekerja sama dengan pelanggan kami di setiap langkah, dari desain konsep hingga pengiriman akhir.

    Produk Lainnya

    Tim kami selalu dipandu oleh kebutuhan pelanggan kami, memberikan konsultasi dan dukungan profesional untuk memastikan kepuasan Anda.

    APA YANG TIDAK BISA ANDA TEMUKAN?

    Bicaralah Dengan Penjualan Kami

    Kami tahu bahwa setiap bisnis unik, jadi kami menawarkan layanan kustom untuk memastikan bahwa produk kami cocok sempurna dengan kebutuhan spesifik Anda:

    • Brosur komprehensif yang dapat Anda unduh
    • Pengalaman pabrik selama 15 tahun
    • Pengiriman cepat
    • OEM&ODM
    • Harga rendah
    • MQQ kecil

    KIRIM KEPADA KAMI EMAIL

    devin@cnspd.com

    Hubungi Kami

    Kami terus menilai dan meningkatkan proses kami untuk memastikan bahwa kami memberikan produk listrik yang paling efisien dan dapat diandalkan di pasar.