Nomor Item: LY1-D20M/2(S)

Spesifikasi Kunci:

Model
LY1-D20M/2(S)

Tipe
Class II+III / Type 2+3 AC SPD

Konfigurasi Tiang
2-Pole Compact Pluggable Design

Protection Mode
L-PE / N-PE

Protection Element
High-Energy MOV

Voltage Options
75V / 150V / 275V / 320V / 385V / 440V AC

In / Imax
10kA / 20kA, 8/20μs

Pemasangan
Rel DIN 35mm

Dapatkan Penawaran Sekarang

    Compact Type 2+3 AC Surge Protection for Two-Pole Circuits

    LY1-D20M/2(S) is a compact two-pole pluggable Type 2+3 AC surge protective device designed for single-phase distribution systems and space-limited control panels. Its high-energy MOV modules provide fast surge limitation through L-PE and N-PE protection paths, with 10kA nominal discharge current and 20kA maximum discharge current.


    Class II+III / Type 2+3 downstream surge protection

    Compact two-pole design with L-PE and N-PE protection

    10kA nominal and 20kA maximum discharge current

    Replaceable cartridges with visual indication and optional remote contact

    Suitable Applications

    LY1-D20M/2(S) is suitable for compact single-phase AC systems requiring two-pole Type 2+3 surge protection in limited DIN-rail space.

    Compact Distribution Boards

    For residential, commercial, and light-industrial panels with limited DIN-rail space.

    Control Cabinets

    Suitable for compact machinery controls, automation cabinets, HVAC systems, and equipment panels.

    🔋

    UPS & Telecom Power

    Helps protect UPS inputs, telecom power supplies, communication equipment, and sensitive electronic loads.

    Solar Inverter AC Boxes

    For single-phase solar inverter AC-side boxes when the selected Uc rating matches the system voltage.

    FAQ

    Common questions about LY1-D20M/2(S) compact two-pole pluggable Type 2+3 AC surge protective device selection.

    What is LY1-D20M/2(S) used for?

    LY1-D20M/2(S) is used for downstream and final-distribution surge protection in compact single-phase AC systems. It helps limit transient overvoltage through two protection paths before the surge reaches connected equipment.

    Is LY1-D20M/2(S) a single-pole or two-pole SPD?

    LY1-D20M/2(S) is a two-pole surge protective device. The existing page title describing it as single-pole should be changed to two-pole.

    Is LY1-D20M/2(S) a Type 2 or Type 3 SPD?

    LY1-D20M/2(S) is classified as Class II+III / Type 2+3, making it suitable for coordinated downstream and final-distribution surge protection.

    Does this product use MOV or GDT protection?

    The product specification identifies high-energy MOV protection. The previous body text describing the complete product as a GDT SPD should be removed to keep the page technically consistent.

    What discharge current ratings does it provide?

    It provides 10kA nominal discharge current In and 20kA maximum discharge current Imax, both based on the 8/20μs current waveform.

    What should be confirmed before ordering?

    Confirm the nominal system voltage, required Uc and Up level, two-pole wiring arrangement, 125A maximum backup-fuse coordination, conductor size, available DIN-rail space, and optional remote-contact requirement.

    Data Teknis

    Electrical, mechanical, environmental, and installation data for LY1-D20M/2(S) compact two-pole pluggable Type 2+3 AC surge protective device selection.

    Parameter 75V 150V 275V 320V 385V 440V
    Listrik IEC
    Nominal AC Voltage Uo / Un 60V 120V 230V 230V 230V 400V
    Maximum Continuous Operating Voltage Uc 75V 150V 275V 320V 385V 440V
    Nominal Discharge Current In, 8/20μs 10kA
    Maximum Discharge Current Imax, 8/20μs 20kA
    Voltage Protection Level Up 0.2kV 0.6kV 1.3kV 1.5kV 1.5kV 1.8kV
    Response Time tA <25ns
    Back-Up Fuse Max. 125A gL / gG
    Short-Circuit Current Rating ISCCR 10kA
    TOV Withstand 5s UT 90V 180V 335V 335V 335V 580V
    TOV 120min UT 115V 230V 440V 440V 440V 765V
    TOV Mode Menahan Menahan Kegagalan Aman Kegagalan Aman Kegagalan Aman Kegagalan Aman
    Mechanical & Environmental
    Operating Temperature Range -40°C to +70°C
    Permissible Operating Humidity 5%–95%
    Atmospheric Pressure / Altitude 80kPa–106kPa / -500m to 2000m
    Terminal Screw Torque 39.9lbf·in / 4.5Nm
    Conductor Cross Section Max. 2 AWG solid/stranded; 4 AWG flexible; 35mm² solid/stranded; 25mm² flexible
    Pemasangan 35mm DIN Rail, EN 60715
    Derajat Perlindungan IP20, built-in
    Bahan Perumahan Thermoplastic, UL94 V-0
    Perlindungan Termal Ya
    Operating State / Fault Indication Green: OK / Red: Defect
    Remote Contacts Optional
    RC Switching Capacity AC 250V / 0.5A; DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
    RC Conductor Cross Section Max. 16 AWG solid / 1.5mm² solid
    Selection Note:
    Confirm the nominal system voltage, required Uc and Up level, two-pole wiring arrangement, 125A maximum backup fuse, conductor size, available DIN-rail space, and optional remote contact before ordering.

    ■ Internal Configuration


    ■ Dimensions & Packaging


    ■ Connection Diagram

    Mulai Kustomisasi Sekarang

    Kami menawarkan berbagai layanan yang disesuaikan, bekerja sama dengan pelanggan kami di setiap langkah, dari desain konsep hingga pengiriman akhir.

    Produk Lainnya

    Tim kami selalu dipandu oleh kebutuhan pelanggan kami, memberikan konsultasi dan dukungan profesional untuk memastikan kepuasan Anda.

    APA YANG TIDAK BISA ANDA TEMUKAN?

    Bicaralah Dengan Penjualan Kami

    Kami tahu bahwa setiap bisnis unik, jadi kami menawarkan layanan kustom untuk memastikan bahwa produk kami cocok sempurna dengan kebutuhan spesifik Anda:

    • Brosur komprehensif yang dapat Anda unduh
    • Pengalaman pabrik selama 15 tahun
    • Pengiriman cepat
    • OEM&ODM
    • Harga rendah
    • MQQ kecil

    KIRIM KEPADA KAMI EMAIL

    devin@cnspd.com

    Hubungi Kami

    Kami terus menilai dan meningkatkan proses kami untuk memastikan bahwa kami memberikan produk listrik yang paling efisien dan dapat diandalkan di pasar.