Articolo n: LY10 Dispositivo di protezione contro le sovratensioni del segnale dati/DC

Key Specifications:

Modello
LY10

Tipo di prodotto
RS485 Data Signal Surge Protector

Tensione nominale di funzionamento
12V / 24V / 48V DC

Maximum Continuous Voltage
15V / 30V / 60V DC

Rated Load Current
500mA

Transmission Rate
Up to 10Mbps

Insertion Loss
≤ 0.2dB

Installazione
35mm DIN-Rail / Terminal Connection

Cita ora

    Reliable Surge Protection for RS485 and Industrial Signal Lines

    LY10 is a DIN-rail-mounted data signal surge protector designed for RS485, telemetry, remote-control, PLC, sensor, and industrial communication lines. Installed in series before sensitive equipment, it helps limit induced transient overvoltage while supporting transmission rates up to 10Mbps with insertion loss of no more than 0.2dB.


    Designed for RS485 and industrial communication circuits

    12V, 24V, and 48V signal-line versions

    Up to 10Mbps transmission with ≤0.2dB insertion loss

    Compact terminal-connected design for DIN-rail control cabinets

    Suitable Applications

    LY10 is suitable for low-voltage data and control lines that require surge protection without significantly affecting signal transmission.

    RS485 Bus Networks

    Protects long-distance RS485 links between controllers, meters, sensors, and field equipment.

    PLC & Automation

    Helps protect PLC interfaces, distributed I/O, machine controls, and factory automation networks.

    🏢

    BMS & HVAC Controls

    Suitable for building management, HVAC, access control, and intelligent monitoring signal lines.

    Solar Monitoring Systems

    Protects inverter communication, tracker-control, weather-station, and solar plant monitoring lines.

    FAQ

    Common questions about LY10 RS485 data signal surge protector selection and installation.

    What is the LY10 data signal surge protector used for?

    LY10 is installed in series with low-voltage communication or control lines to help suppress induced transient overvoltage before it reaches sensitive equipment.

    Is LY10 suitable for RS485 networks?

    Yes. It is designed for RS485 and similar industrial data lines used by PLCs, meters, sensors, automation controllers, and remote-monitoring equipment.

    Which voltage version should be selected?

    Select the 12V, 24V, or 48V version according to the normal operating voltage of the protected signal circuit. The corresponding maximum continuous voltage is 15V, 30V, or 60V.

    Will LY10 affect data transmission?

    The listed transmission rate is up to 10Mbps and the listed insertion loss is no more than 0.2dB. The actual protocol, impedance, baud rate, and cable length should still be confirmed.

    How should the LY10 be installed?

    Mount it on a DIN rail and connect it in series before the protected equipment. Follow the input and protected-side markings, and keep the grounding connection as short and direct as possible.

    What should be confirmed before ordering?

    Confirm the signal voltage, maximum continuous voltage, line current, protocol, baud rate, number of conductors, terminal arrangement, grounding method, and required surge withstand level.

    Dati tecnici

    Signal-circuit, surge-withstand, transmission, and installation data for LY10 RS485 data signal surge protector selection.

    Parametro12V Version24V Version48V Version
    Signal Circuit Ratings
    ModelloLY10
    Tipo di prodottoRS485 / Data Signal Surge Protector
    Tensione nominale di funzionamento12V DC24V DC48V DC
    Maximum Continuous Operating Voltage15V DC30V DC60V DC
    Rated Load Current500mA
    Surge & Transmission Performance
    Listed Surge Withstand Capacity10kV / 5kA*
    Clamping Voltage, Line-to-Line, 1.2/50μs60V80V160V
    Maximum Transmission Rate10Mbps
    Insertion Loss≤ 0.2dB
    Installazione
    Interface TypeConnection Terminal
    Mounting Method35mm DIN Rail
    Installation MethodSeries Connection Before Protected Equipment
    Grado di protezioneIP20
    Selection Note:
    Match the 12V, 24V, or 48V version to the protected signal circuit. Confirm the protocol, baud rate, load current, number of conductors, line impedance, terminal arrangement, grounding method, and cable length before ordering.

    Parameter Check:
    The current page lists the surge-withstand value only as “10kV & 5kA” without defining all test waveforms, protection modes, or measurement conditions. Confirm these details against the official test report before using them in formal quotations or certificates.

    Iniziare a personalizzare ora

    Offriamo una gamma completa di servizi personalizzati, lavorando a stretto contatto con i nostri clienti in ogni fase del processo, dalla progettazione alla consegna finale.

    Altri prodotti

    Il nostro team è sempre guidato dalle esigenze dei nostri clienti, fornendo consulenza e assistenza professionale per garantire la vostra soddisfazione.

    TUTTO CIÒ CHE NON SEI RIUSCITO A TROVARE.

    Parlate con le nostre vendite

    Sappiamo che ogni azienda è unica, quindi offriamo servizi personalizzati per garantire che i nostri prodotti si adattino perfettamente alle vostre esigenze specifiche:

    • Una brochure completa da scaricare
    • 15 anni di esperienza in fabbrica
    • Consegna veloce
    • OEM&ODM
    • Prezzo basso
    • Piccolo MQQ

    INVIATECI UN'E-MAIL

    devin@cnspd.com

    Contatto

    Valutiamo e miglioriamo costantemente i nostri processi per garantire la fornitura dei prodotti elettrici più efficienti e affidabili del mercato.