Nº do artigo: LY26-XF Sinal SPD

Especificações Principais:

Modelo
LY26-XF

Tipo de produto
Waterproof Explosion-Proof Signal SPD

Rated Voltage Options
5V / 12V / 24V / 48V / 110V / 220V

Maximum Continuous Voltage
6V / 15V / 30V / 50V / 230V / 420V

Corrente de descarga nominal
In 5kA, 8/20μs

Tempo de resposta
≤ 1ns

Insertion Loss
≤ 0.3dB

Protection Circuits
Single-Channel or Dual-Channel

Citar agora

    Waterproof Surge Protection for Outdoor and Hazardous Signal Lines

    LY26-XF is a waterproof and explosion-proof signal surge protective device designed for RS485 data transmission, industrial communication, and field-control lines. Its multistage semiconductor protection provides fast transient suppression, low residual voltage, and low insertion loss for sensitive equipment installed outdoors or in demanding industrial environments.


    Waterproof enclosure for outdoor signal-line installations

    Suitable for RS485, communication, and control signal lines

    Fast response time of no more than 1ns

    Single-channel and dual-channel protection options

    Aplicações Adequadas

    LY26-XF is designed for outdoor and industrial signal circuits that require reliable surge protection, moisture resistance, and a robust enclosed construction.

    RS485 Control Lines

    Protects RS485 data transmission and industrial control circuits exposed to induced surges.

    🏭

    Chemical Plants

    Suitable for field-control and data lines in chemical workshops and other demanding industrial locations.

    Fuel & Gas Facilities

    For signal lines in gas stations, oil depots, gas storage areas, and fuel-handling facilities.

    📹

    Outdoor Security Systems

    Helps protect outdoor monitoring, alarm, access-control, firefighting, and security signal circuits.

    FAQ

    Common questions about LY26-XF waterproof and explosion-proof signal-line surge protection.

    Para que é utilizado o LY26-XF?

    O LY26-XF é projetado para proteger linhas de comunicação de dados RS485 e linhas de sinal de controle de campo contra sobretensões induzidas por relâmpagos e transientes de comutação.

    O LY26-XF é adequado para instalação externa?

    Sim. Ele utiliza uma caixa selada à prova d'água e é destinado a aplicações de linha de sinal ao ar livre, onde a umidade e a exposição ambiental devem ser consideradas.

    Qual versão de voltagem deve ser selecionada?

    Selecione a versão de 5V, 12V, 24V, 48V, 110V ou 220V de acordo com a tensão de operação normal do circuito de sinal protegido e a correspondente tensão máxima contínua.

    Does LY26-XF support single-channel and dual-channel protection?

    Yes. The product is available with single-channel protection for terminals 1 and 2, or dual-channel protection for terminals 1, 2, 3, and 4.

    Will the protector significantly affect the signal?

    The listed insertion loss is no more than 0.3dB. Final compatibility should still be checked against the actual protocol, line impedance, transmission distance, and signal frequency.

    O que deve ser confirmado antes de fazer o pedido?

    Confirm the signal voltage, maximum continuous voltage, number of protected channels, wiring arrangement, communication protocol, installation environment, grounding method, enclosure requirements, and required certification.

    Dados técnicos

    Electrical, signal-performance, enclosure, and circuit-configuration data for LY26-XF waterproof explosion-proof signal surge protector selection.

    Parâmetro 5V 12V 24V 48V 110V 220V
    Signal Circuit Ratings
    Modelo LY26-XF
    Rated Operating Voltage Un 5V 12V 24V 48V 110V 220V
    Tensão de Operação Contínua Máxima Uc 6V 15V 30V 50V 230V 420V
    Surge & Signal Performance
    Corrente Nominal de Descarga In, 8/20μs 5kA
    Tempo de resposta ≤ 1ns
    Insertion Loss ≤ 0.3dB
    Enclosure & Circuit Configuration
    Housing Waterproof and Explosion-Proof Enclosure
    Single-Channel Protection Circuit Terminals 1 and 2
    Dual-Channel Protection Circuit Terminals 1, 2, 3 and 4
    Typical Protected Lines RS485, Data Communication and Field-Control Signal Lines
    Installation Zone Signal equipment interface from LPZ 1 to LPZ 3
    Nota de Seleção:
    Select the voltage version according to the normal operating voltage and maximum continuous voltage of the protected signal line. Confirm the single-channel or dual-channel wiring arrangement, communication protocol, signal frequency, grounding method, enclosure installation, and hazardous-area requirements before ordering.

    Certification Note:
    “Explosion-proof” requirements vary by country and application. Confirm the exact explosion-protection certificate, marking, gas group, temperature class, enclosure rating, and installation method before using the product in a regulated hazardous area.

    Comece a personalizar agora

    Oferecemos uma gama completa de serviços personalizados, trabalhando em estreita colaboração com os nossos clientes em todas as fases do processo, desde a conceção até à entrega final.

    Outros&Produtos

    A nossa equipa é sempre guiada pelas necessidades dos nossos clientes, fornecendo aconselhamento profissional e apoio para garantir a sua satisfação.

    QUALQUER COISA QUE NÃO CONSEGUISTE ENCONTRAR?

    Fale com os nossos comerciais

    Sabemos que cada empresa é única, por isso oferecemos serviços personalizados para garantir que os nossos produtos correspondem perfeitamente às suas necessidades específicas:

    • Brochura completa que pode ser descarregada
    • 15 anos de experiência na fábrica
    • Entrega rápida
    • OEM&ODM
    • Preço baixo
    • Pequena MQQ

    ENVIAR-NOS UMA MENSAGEM DE CORREIO ELECTRÓNICO

    devin@cnspd.com

    Contactar-nos

    Avaliamos e melhoramos constantemente os nossos processos para garantir que estamos a fornecer os produtos eléctricos mais eficientes e fiáveis do mercado.