Numéro d'article : LY1-C40/1(S)

Key Specifications:

Modèle
LY1-C40/1(S)

Type
Class II / Type 2 AC SPD

Pole Configuration
1P Single-Pole Design

Protection Element
High-Energy MOV

Voltage Options
75V / 150V / 275V / 320V / 385V / 440V AC

In / Imax
20kA / 40kA, 8/20μs

Impulse Current
Iimp 7kA, 10/350μs

Montage
35mm DIN Rail

Citer maintenant

    Reliable Type 2 AC Surge Protection for Distribution Circuits

    LY1-C40/1(S) is a single-pole pluggable Type 2 AC surge protective device designed for low-voltage distribution boards and equipment panels. Its high-energy MOV module provides fast transient-voltage limitation with 20kA nominal discharge current, 40kA maximum discharge current, and a replaceable cartridge for easier maintenance.


    Class II / Type 2 protection for low-voltage AC circuits

    20kA In and 40kA Imax surge discharge capability

    75V to 440V AC versions for different system requirements

    Pluggable cartridge with visual indication and optional remote contact

    Suitable Applications

    LY1-C40/1(S) is suitable for low-voltage AC circuits requiring modular Type 2 surge protection in distribution boards, control cabinets, and equipment power systems.

    Distribution Boards

    For Type 2 surge protection in residential, commercial, and industrial distribution boards.

    Control Cabinets

    Suitable for machinery controls, automation cabinets, HVAC systems, and equipment panels.

    🏢

    Commercial Power Systems

    Helps protect offices, retail facilities, and building electrical systems from transient overvoltage.

    Solar AC Panels

    For solar inverter AC-side panels when the selected Uc rating matches the system voltage.

    FAQ

    Common questions about LY1-C40/1(S) single-pole pluggable Type 2 AC surge protective device selection and installation.

    What is LY1-C40/1(S) used for?

    LY1-C40/1(S) is used to limit transient overvoltage in low-voltage AC distribution circuits. It can be installed as a single-pole protection module or combined with matching modules for a multi-pole arrangement.

    Is LY1-C40/1(S) a Type 2 SPD?

    Yes. LY1-C40/1(S) is classified as a Class II / Type 2 AC surge protective device for low-voltage distribution systems.

    What discharge current ratings does it provide?

    It provides 20kA nominal discharge current In, 40kA maximum discharge current Imax, and a listed 7kA impulse-current rating.

    What voltage options are available?

    Maximum continuous operating voltage options include 75V, 150V, 275V, 320V, 385V, and 440V AC. The correct version must be selected according to the nominal system voltage.

    What is the benefit of the pluggable design?

    The replaceable cartridge allows the surge module to be inspected or replaced without removing the permanently wired base, reducing maintenance time.

    What should be confirmed before ordering?

    Confirm the nominal system voltage, required Uc and Up level, pole configuration, 125A maximum backup-fuse coordination, conductor size, DIN-rail space, and remote-contact requirement.

    Données techniques

    Electrical, mechanical, environmental, and installation data for LY1-C40/1(S) single-pole pluggable Type 2 AC surge protective device selection.

    Paramètres75V150V275V320V385V440V
    Électrique IEC
    Nominal AC Voltage Uo / Un60V120V230V230V230V400V
    Maximum Continuous Operating Voltage Uc75V150V275V320V385V440V
    Nominal Discharge Current In, 8/20μs20kA
    Maximum Discharge Current Imax, 8/20μs40kA
    Impulse Current Iimp, 10/350μs7kA
    Voltage Protection Level Up0.4kV1.0kV1.5kV1.6kV1.8kV2.0kV
    Response Time tA<25ns
    Back-Up Fuse Max.125A gL / gG
    Short-Circuit Current Rating ISCCR25kA / 50kA
    TOV Withstand 5s UT90V180V335V335V335V580V
    TOV 120min UT115V230V440V440V440V765V
    TOV ModeRésistanceRésistanceDéfaut de sécuritéDéfaut de sécuritéDéfaut de sécuritéDéfaut de sécurité
    Mécanique et environnement
    Plage de température de fonctionnement-40°F to +158°F [-40°C to +70°C]
    Humidité de fonctionnement admissible5%–95%
    Atmospheric Pressure / Altitude80kPa–106kPa / -500m to 2000m
    Couple de serrage de la vis de fixation39.9 lbf·in [4.5Nm]
    Conductor Cross Section Max.2 AWG solid/stranded; 4 AWG flexible; 35mm² solid/stranded; 25mm² flexible
    Montage35mm DIN Rail, EN 60715
    Degré de protectionIP20, built-in
    Matériau du boîtierThermoplastic, UL94 V-0
    Protection thermiqueOui
    État de fonctionnement / Indication de défautGreen: OK / Red: Defect
    Remote ContactsEn option
    Capacité de commutation RCAC 250V / 0.5A; DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
    RC Conductor Cross Section Max.16 AWG solid / 1.5mm² solid
    Selection Note:
    Confirm the nominal system voltage, required Uc and Up level, pole configuration, 125A maximum backup fuse, conductor size, DIN-rail space, and optional remote contact before ordering.

    ■ Configuration interne


    ■ Dimensions et emballage


    ■ Schéma de connexion

    Commencez à personnaliser maintenant

    Nous offrons une gamme complète de services personnalisés, en travaillant en étroite collaboration avec nos clients à chaque étape, de la conception à la livraison finale.

    Autres&Produits

    Notre équipe est toujours guidée par les besoins de nos clients, fournissant une consultation et un soutien professionnels pour assurer votre satisfaction.

    TOUT CE QUE VOUS N'AVEZ PAS PU TROUVER?

    Parlez avec nos vendeurs

    Nous savons que chaque entreprise est unique, c'est pourquoi nous proposons des services personnalisés afin de garantir que nos produits répondent parfaitement à vos besoins spécifiques :

    • Brochure complète à télécharger
    • 15 ans d'expérience en usine
    • Livraison rapide
    • OEM&ODM
    • Prix bas
    • Petit MQQ

    ENVOYEZ-NOUS UN COURRIEL

    devin@cnspd.com

    Nous contacter

    Nous évaluons et améliorons constamment nos processus pour nous assurer que nous fournissons les produits électriques les plus efficaces et les plus fiables du marché.