Reliable Type 2 Surge Protection for 600V DC Systems
LY1-C40PV/3(S) 600V is a three-pole pluggable Type 2 DC surge protective device designed for photovoltaic combiner boxes, inverter DC inputs, telecom power cabinets, energy-storage systems, and industrial DC distribution panels. Its high-energy MOV modules provide fast surge limitation with 20kA nominal discharge current and 40kA maximum discharge current.
Class II / Type 2 protection for systems up to 600V DC
Three-pole pluggable design for multi-line DC circuits
Arus nominal 20kA dan arus maksimum 40kA
Replaceable modules with visual indication and optional remote contact
Aplikasi Yang Sesuai
LY1-C40PV/3(S) 600V is suitable for photovoltaic and industrial DC systems requiring three-pole Type 2 surge protection.
Kotak Penggabung PV
Protects photovoltaic strings and 600V DC combiner-box circuits against transient overvoltage.
PV Inverter DC Inputs
Suitable for protecting compatible string, hybrid, and commercial solar inverter DC inputs.
Telecom DC Cabinets
Helps protect telecom power racks, base-station DC cabinets, and communication power equipment.
Energy Storage Systems
Suitable for compatible battery cabinets and energy-storage DC distribution circuits up to 600V DC.
FAQ
Common questions about LY1-C40PV/3(S) 600V three-pole pluggable Type 2 DC surge protective device selection.
Apa fungsi LY1-C40PV/3(S) 600V?
Ini dirancang untuk membatasi lonjakan voltase transien yang disebabkan oleh petir dan switching dalam sistem DC fotovoltaik, telekomunikasi, penyimpanan energi, dan industri yang beroperasi hingga 600V DC.
Apakah LY1-C40PV/3(S) 600V adalah SPD DC Tipe 2?
Yes. The product is classified as Class II / Type 2 according to the current product specification and is intended for downstream DC surge protection.
What does the three-pole configuration protect?
The three-pole configuration is intended for multi-line DC systems requiring coordinated protection of positive, negative, and an additional monitored or grounded protection path. Installation must follow the supplied wiring diagram.
What discharge-current ratings does it provide?
It provides 20kA nominal discharge current In and 40kA maximum discharge current Imax, both based on an 8/20μs current waveform.
Can the protection modules be replaced separately?
Yes. Its pluggable design allows individual protection modules to be inspected or replaced without removing the permanently wired base.
Apa yang harus dikonfirmasi sebelum memesan?
Confirm the maximum system voltage, three-pole wiring arrangement, grounding system, required voltage protection level, backup-fuse coordination, conductor size, installation location, and optional remote-contact requirement.