Reliable Type 2 Surge Protection for 600V DC Systems
LY1-C40PV/3(S) 600V is a three-pole pluggable Type 2 DC surge protective device designed for photovoltaic combiner boxes, inverter DC inputs, telecom power cabinets, energy-storage systems, and industrial DC distribution panels. Its high-energy MOV modules provide fast surge limitation with 20kA nominal discharge current and 40kA maximum discharge current.
Class II / Type 2 protection for systems up to 600V DC
Three-pole pluggable design for multi-line DC circuits
Courant de décharge nominal de 20kA et courant maximum de 40kA
Replaceable modules with visual indication and optional remote contact
Applications appropriées
LY1-C40PV/3(S) 600V is suitable for photovoltaic and industrial DC systems requiring three-pole Type 2 surge protection.
Boîtes combinées PV
Protects photovoltaic strings and 600V DC combiner-box circuits against transient overvoltage.
Entrées DC d'onduleurs photovoltaïques
Suitable for protecting compatible string, hybrid, and commercial solar inverter DC inputs.
Telecom DC Cabinets
Helps protect telecom power racks, base-station DC cabinets, and communication power equipment.
Energy Storage Systems
Suitable for compatible battery cabinets and energy-storage DC distribution circuits up to 600V DC.
FAQ
Common questions about LY1-C40PV/3(S) 600V three-pole pluggable Type 2 DC surge protective device selection.
What is LY1-C40PV/3(S) 600V used for?
It is designed to limit lightning-induced and switching transient overvoltage in photovoltaic, telecom, energy-storage, and industrial DC systems operating up to 600V DC.
Is LY1-C40PV/3(S) 600V a Type 2 DC SPD?
Yes. The product is classified as Class II / Type 2 according to the current product specification and is intended for downstream DC surge protection.
What does the three-pole configuration protect?
The three-pole configuration is intended for multi-line DC systems requiring coordinated protection of positive, negative, and an additional monitored or grounded protection path. Installation must follow the supplied wiring diagram.
What discharge-current ratings does it provide?
It provides 20kA nominal discharge current In and 40kA maximum discharge current Imax, both based on an 8/20μs current waveform.
Les modules de protection peuvent-ils être remplacés séparément ?
Yes. Its pluggable design allows individual protection modules to be inspected or replaced without removing the permanently wired base.
Que doit-on confirmer avant de commander ?
Confirm the maximum system voltage, three-pole wiring arrangement, grounding system, required voltage protection level, backup-fuse coordination, conductor size, installation location, and optional remote-contact requirement.